The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Degradable and Removable Tough Adhesive Hydrogels
Open accessAbstract
The development of tough adhesive hydrogels has enabled unprecedented adhesion to wet and moving tissue surfaces throughout the body, but they are typically composed of nondegradable components. Here, a family of degradable tough adhesive hydrogels containing ≈90% water by incorporating covalently networked degradable crosslinkers and hydrolyzable ionically crosslinked main‐chain polymers is developed. Mechanical toughness, adhesion, and degradation of these new formulations are tested in both accelerated in vitro conditions and up to 16 weeks in vivo. These degradable tough adhesives are engineered with equivalent mechanical and adhesive properties to nondegradable tough adhesives, capable of achieving stretches >20 times their initial length, fracture energies >6 kJ m−2, and adhesion energies >1000 J m−2. All degradable systems show complete degradation within 2 weeks under accelerated aging conditions in vitro and weeks to months in vivo depending on the degradable crosslinker selected. Excellent biocompatibility is observed for all groups after 1, 2, 4, 8, and 16 weeks of implantation, with minimal fibrous encapsulation and no signs of organ toxicity. On‐demand removal of the adhesive is achieved with treatment of chemical agents which do not cause damage to underlying skin tissue in mice. The broad versatility of this family of adhesives provides the foundation for numerous in vivo indications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Synthesis, properties, and biomedical applications of gelatin methacryloyl (GelMA) hydrogels
Yue, K., Trujillo-de Santiago, G., Alvarez, M. M., Tamayol, A., Annabi, N., & Khademhosseini, A. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.08.045 · Cited by 3,146
Controlled Degradation and Mechanical Behavior of Photopolymerized Hyaluronic Acid Networks
Burdick, J. A., Chung, C., Jia, X., Randolph, M. A., & Langer, R. (2005) · Biomacromolecules · doi:10.1021/bm049508a · Cited by 777
Cited by
Recent advances in conductive hydrogels: classifications, properties, and applications
Zhu, T., Ni, Y., Biesold, G. M., Cheng, Y., Ge, M., Li, H., Huang, J., Lin, Z., & Lai, Y. (2023) · Chemical Society Reviews · doi:10.1039/d2cs00173j · Cited by 738
Development of alginate-based hydrogels: Crosslinking strategies and biomedical applications
Tan, J., Luo, Y., Guo, Y., Zhou, Y., Liao, X., Li, D., Lai, X., & Liu, Y. (2023) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2023.124275 · Cited by 308
Jiang, Y., Zhang, X., Zhang, W., Wang, M., Yan, L., Wang, K., Han, L., & Lu, X. (2022) · ACS Nano · doi:10.1021/acsnano.2c00662 · Cited by 296
Rapid fabrication of physically robust hydrogels
Bao, B., Zeng, Q., Li, K., Wen, J., Zhang, Y., Zheng, Y., Zhou, R., Shi, C., Chen, T., Xiao, C., et al. (2023) · Nature Materials · doi:10.1038/s41563-023-01648-4 · Cited by 293
Magneto‐Responsive Microneedle Robots for Intestinal Macromolecule Delivery
Zhang, X., Chen, G., Fu, X., Wang, Y., & Zhao, Y. (2021) · Advanced Materials · doi:10.1002/adma.202104932 · Cited by 263
Metadata
- Authors
- Freedman, B. R., Uzun, O., Luna, N. M. M., Rock, A., Clifford, C., Stoler, E., Östlund‐Sholars, G., Johnson, C., & Mooney, D. J.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2021-03-24
- Volume
- 33
- Issue
- 17
- Pages
- e2008553-e2008553
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W3138870718
- Cited by
- 222
- References
- 2
- FWCI
- 8.91
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.