The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Self‐Powered Gesture Recognition Wristband Enabled by Machine Learning for Full Keyboard and Multicommand Input
Abstract
Virtual reality is a brand‐new technology that can be applied extensively. To realize virtual reality, certain types of human–computer interaction equipment are necessary. Existing virtual reality technologies often rely on cameras, data gloves, game pads, and other equipment. These equipment are either bulky, inconvenient to carry and use, or expensive to popularize. Therefore, the development of a convenient and low‐cost high‐precision human–computer interaction device can contribute positively to the development of virtual reality technology. In this study, a gesture recognition wristband that can realize a full keyboard and multicommand input is developed. The wristband is convenient to wear, low in cost, and does not affect other daily operations of the hand. This wristband is based on physiological anatomy as well as aided by active sensor and machine learning technology; it can achieve a maximum accuracy of 92.6% in recognizing 26 letters. This wristband offers broad application prospects in the fields of gesture command recognition, assistive devices for the disabled, and wearable electronics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
Wearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Yang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641
Wen, F., Zhang, Z., He, T., & Lee, C. (2021) · Nature Communications · doi:10.1038/s41467-021-25637-w · Cited by 494
Cited by
Sun, T., Feng, B., Huo, J., Xiao, Y., Wang, W., Peng, J., Li, Z., Du, C., Wang, W., Zou, G., et al. (2024) · Nano-Micro Letters · doi:10.1007/s40820-023-01235-x · Cited by 384
Self-citationZhang, H., Zhang, D., Wang, Z., Xi, G., Mao, R., Ma, Y., Wang, D., Tang, M., Xu, Z., & Luan, H. (2023) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.2c17904 · Cited by 330
Self-citationToward an AI Era: Advances in Electronic Skins
Fu, X., Cheng, W., Wan, G., Yang, Z., & Tee, B. C. K. (2024) · Chemical Reviews · doi:10.1021/acs.chemrev.4c00049 · Cited by 172
Wang, T., Ouyang, H., Luo, Y., Xue, J., Wang, E., Zhang, L., Zhou, Z., Liu, Z., Li, X., Tan, S., et al. (2024) · Science Advances · doi:10.1126/sciadv.adi6799 · Cited by 161
Self-citationUnderstanding How Blind Users Handle Object Recognition Errors: Strategies and Challenges
Hong, J., & Kacorri, H. (2024) · The 26th International ACM SIGACCESS Conference on Computers and Accessibility · doi:10.1145/3663548.3675635 · Cited by 14
Metadata
- Authors
- Tan, P., Han, X., Zou, Y., Qu, X., Xue, J., Li, T., Wang, Y., Luo, R., Cui, X., Xi, Y., Wu, L., Xue, B., Luo, D., Fan, Y., Chen, X., Li, Z., & Wang, Z. L.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2022-04-27
- Volume
- 34
- Issue
- 21
- Pages
- e2200793-e2200793
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W4220788735
- Cited by
- 215
- References
- 4
- FWCI
- 21.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Self‐Powered Gesture Recognition Wristband Enabled by Machine Learning for Full Keyboard and Multicommand Input. https://app.cochat.ai/papers/10.1002/adma.202200793
- The paper
- Tan, P., Han, X., Zou, Y., Qu, X., Xue, J., Li, T., Wang, Y., Luo, R., Cui, X., Xi, Y., Wu, L., Xue, B., Luo, D., Fan, Y., Chen, X., Li, Z., & Wang, Z. L. (2022). Self‐Powered Gesture Recognition Wristband Enabled by Machine Learning for Full Keyboard and Multicommand Input. Advanced Materials. https://doi.org/10.1002/adma.202200793
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.