The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
A Nonswelling Hydrogel with Regenerable High Wet Tissue Adhesion for Bioelectronics
Abstract
Reducing the swelling of tissue‐adhesive hydrogels is crucial for maintaining stable tissue adhesion and inhibiting tissue inflammation. However, reported strategies for reducing swelling always result in a simultaneous decrease in the tissue adhesive strength of the hydrogel. Furthermore, once the covalent bonds break in the currently reported hydrogels, they cannot be rebuilt, and the hydrogel loses its tissue adhesive ability. In this work, a nonswelling hydrogel (named as “PAACP”) possessing regenerable high tissue adhesion is synthesized by copolymerizing and crosslinking poly(vinyl butyral) with acrylic acid, gelatin, and chitosan‐grafted N‐acetyl‐l‐cysteine. The tissue adhesive strength of the obtained PAACP reaches 211.4 kPa, which is approximately ten times higher than that of the reported nonswelling hydrogels, and the hydrogel can be reused for multiple cycles. The as‐prepared hydrogel shows great potential in soft bioelectronics, as muscle fatigue is successfully monitored via the electrode array and strain sensor integrated on PAACP substrates. The success of these bioelectronics offers potential applicability in the long‐term diagnosis of muscle‐related health conditions and prosthetic manipulations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhao, X., Liang, Y., Huang, Y., He, J., Han, Y., & Guo, B. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201910748 · Cited by 814
A Highly Elastic, Capacitive Strain Gauge Based on Percolating Nanotube Networks
Cohen, D. J., Mitra, D., Peterson, K., & Maharbiz, M. M. (2012) · Nano Letters · doi:10.1021/nl204052z · Cited by 501
In vitro electrical properties for iridium oxide versus titanium nitride stimulating electrodes
Weiland, J. D., Anderson, D. J., & Humayun, M. S. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.805487 · Cited by 382
Viscoelastic surface electrode arrays to interface with viscoelastic tissues
Tringides, C. M., Vachicouras, N., de Lázaro, I., Wang, H., Trouillet, A., Seo, B. R., Elosegui-Artola, A., Fallegger, F., Shin, Y., Casiraghi, C., et al. (2021) · Nature Nanotechnology · doi:10.1038/s41565-021-00926-z · Cited by 309
Stretchable E‐Skin Apexcardiogram Sensor
You, I., Kim, B., Park, J., Koh, K., Shin, S., Jung, S., & Jeong, U. (2016) · Advanced Materials · doi:10.1002/adma.201600720 · Cited by 213
Recent advances in neurotechnologies with broad potential for neuroscience research
Vázquez-Guardado, A., Yang, Y., Bandodkar, A. J., & Rogers, J. A. (2020) · Nature Neuroscience · doi:10.1038/s41593-020-00739-8 · Cited by 202
Cited by
Self‐Healing Hydrogel Bioelectronics
Li, Z., Lu, J., Ji, T., Xue, Y., Zhao, L., Zhao, K., Jia, B., Wang, B., Wang, J., Zhang, S., et al. (2024) · Advanced Materials · doi:10.1002/adma.202306350 · Cited by 257
Metadata
- Authors
- Tian, G., Yang, D., Liang, C., Liu, Y., Chen, J., Zhao, Q., Tang, S., Huang, J., Xu, P., Liu, Z., & Qi, D.
- Venue
- Advanced Materials
- Publisher
- Wiley
- Published
- 2023-03-17
- Volume
- 35
- Issue
- 18
- Pages
- e2212302-e2212302
- ISSN
- 0935-9648 (ISSN-L)
- 1521-4095
- OpenAlex
- W4319262113
- Cited by
- 219
- References
- 6
- FWCI
- 15.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.