The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
EGaIn–Metal Interfacing for Liquid Metal Circuitry and Microelectronics Integration
Abstract
Eutectic gallium–indium (EGaIn) has attracted significant attention in recent years for its use in soft and stretchable electronics. However, advances in scalable fabrication approaches and effective electromechanical interfaces between liquid metal (LM) traces and microelectronics are still needed to create functional soft and stretchable electronics. In this study, EGaIn–metal interfacing for the effective integration of surface‐mount microelectronics with LM interconnects is investigated. The electrical interconnects are produced by creating copper patterns on a soft‐elastomer substrate, and subsequently exposing the substrate to EGaIn, which selectively wets the Cu traces. To create strong electromechanical connection between EGaIn and microelectronics, the terminals of the LM‐coated traces are “soldered” to the metal pins of the packaged microelectronic circuits using a novel HCl‐vapor treatment. In combination, the fabrication and microelectronics‐interfacing approaches enable creating stretchable circuits composed of LM wiring and packaged microelectronics. It is found that the HCl‐vapor treatment significantly improves electrical conductivity at the LM–pin interface while enhancing the strain limit of the soft circuits and the reproducibility of the interface. The applicability of this approach in creating soft‐matter circuits is demonstrated through two illustrative examples—a circuit with a digital 9‐axis inertial measurement unit and a temperature sensor; and a circuit with a 3‐axis analog accelerometer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
An ultra-lightweight design for imperceptible plastic electronics
Kaltenbrunner, M., Sekitani, T., Reeder, J., Yokota, T., Kuribara, K., Tokuhara, T., Drack, M., Schwödiauer, R., Graz, I., Bauer-Gogonea, S., et al. (2013) · Nature · doi:10.1038/nature12314 · Cited by 2,485
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Zhang, Y., Wang, S., Li, X., Fan, J. A., Xu, S., Song, Y. M., Choi, K., Yeo, W., Lee, W., Nazaar, S. N., et al. (2014) · Advanced Functional Materials · doi:10.1002/adfm.201302957 · Cited by 354
Cited by
Highly stretchable multilayer electronic circuits using biphasic gallium-indium
Liu, S., Shah, D. S., & Kramer-Bottiglio, R. (2021) · Nature Materials · doi:10.1038/s41563-021-00921-8 · Cited by 409
Soft‐Matter Engineering for Soft Robotics
Majidi, C. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201800477 · Cited by 358
Self-citationLiquid Metal Direct Write and 3D Printing: A Review
Neumann, T. V., & Dickey, M. D. (2020) · Advanced Materials Technologies · doi:10.1002/admt.202000070 · Cited by 332
Wearable Soft Technologies for Haptic Sensing and Feedback
Yin, J., Hinchet, R., Shea, H., & Majidi, C. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202007428 · Cited by 325
Self-citationShaping a Soft Future: Patterning Liquid Metals
Ma, J., Krisnadi, F., Vong, M. H., Kong, M., Awartani, O. M., & Dickey, M. D. (2023) · Advanced Materials · doi:10.1002/adma.202205196 · Cited by 311
Metadata
- Authors
- Ozutemiz, K. B., Wissman, J., Ozdoganlar, O. B., & Majidi, C.
- Venue
- Advanced Materials Interfaces
- Publisher
- Wiley
- Published
- 2018-03-15
- Volume
- 5
- Issue
- 10
- ISSN
- 2196-7350 (ISSN-L)
- OpenAlex
- W2792445290
- Cited by
- 251
- References
- 4
- FWCI
- 8.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.