Cited by 77Gas Sensing Nanomaterials and SensorsAdvanced Fiber Optic SensorsSpectroscopy and Laser Applications

Ultrasensitive Exhaled Breath Sensors Based on Anti‐Resonant Hollow Core Fiber with In Situ Grown ZnO‐Bi2O3 Nanosheets

Liu, Wei, Zheng, Yu, Wang, Zhe, Wang, Zhixun, Yang, Jiao, Chen, Mengxiao, Qi, Miao, Ur Rehman, Shafiq +3 more·2021·Advanced Materials Interfaces

Abstract

Combination of anti‐resonant hollow‐core fiber (HCF) and semiconductor nanomaterial is an effective strategy to obtain high‐performance gas sensors with exceptional sensitivity and low power consumption. However, controlling the semiconductor morphology onto HCF is a major challenge to achieve the desired gas sensor with the enhanced sensitivity. Here, a ZnO‐Bi 2 O 3 nanosheets (NSs) heterostructure is grown in situ on the surface of HCF by sol–gel and hydrothermal methods. ZnO‐Bi 2 O 3 NSs serving as electron acceptors trap electrons after acetone adsorption and then change the refractive index of the surface of HCF. Benefiting from the unique sheet structure and the synergetic effects for multi‐component, the resulting ZnO‐Bi 2 O 3 NSs enabled HCF gas sensor exhibits high sensitivity, selectivity, and repeatability for detecting acetone at room temperature, particularly in the low concentration range, with the theoretical limit of detection down to 140 parts‐per‐billion. Meanwhile, the successful application of the ZnO‐Bi 2 O 3 NSs enabled HCF gas sensor to distinguish the exhaled breath from the healthy individuals and simulated diabetic cases is demonstrated, which paves the way to achieve non‐invasive, ultra‐sensitivity gas sensing at room temperature for the early diagnosis of diabetes.

Integrity signals

Registry

Crossref · 10.1002/admi.202001978

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cited by

Sorted by citations

Authors
Liu, W., Zheng, Y., Wang, Z., Wang, Z., Yang, J., Chen, M., Qi, M., Ur Rehman, S., Shum, P. P., Zhu, L., & Wei, L.
Affiliations
  • Nanyang Technological University (SG)
  • Key Laboratory of Optoelectronic Device and Systems of Ministry of Education and Guangdong Province College of Optoelectronic Engineering Shenzhen University Shenzhen 518060 P. R. China
  • Southern University of Science and Technology (CN)
  • Shenzhen University (CN)
  • Centre National de la Recherche Scientifique (FR)
Corresponding author
  • Zhu, Ling
  • Wei, Lei
Venue
Advanced Materials Interfaces
Publisher
Wiley
Published
2021-02
Volume
8
Issue
6
ISSN
2196-7350 (ISSN-L)
OpenAlex
W3203001635
Cited by
77
References
0
Citations by year
2026: 2 · 2025: 10 · 2024: 5 · 2023: 7 · 2022: 51 · 2021: 2
FWCI
4.78
Type
journal article
Language
en
Open access
closed
Locations
  • Advanced Materials Interfaces (publishedVersion)
  • DR-NTU (Nanyang Technological University) (submittedVersion)
Funders
  • Agency for Science, Technology and Research (A2083c0062)
  • National Research Foundation Singapore (NRF‐CRP18‐2017‐02)
  • Ministry of Education - Singapore (MOE2019‐T2‐2‐127, T2EP50120‐000, RG90/19)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Gas Sensing Nanomaterials and Sensors
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Fiber Optic Sensors
  • Physical Sciences › Chemistry › Spectroscopy › Spectroscopy and Laser Applications
Keywords
anti-resonant hollow-core fiber, acetone detection, room-temperature gas sensing, in situ growth, heterostructures, electron acceptors, refractive index change, diabetes diagnosis, non-invasive diagnosis, low-concentration detection

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review