The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
A Triboelectric Nanogenerator‐Based Smart Insole for Multifunctional Gait Monitoring
Abstract
Accurately monitoring human gait is critical for health evaluation and/or early diagnosis, especially for elder and injured people's healthcare. The presence of gait abnormalities could be important predictors of the risk of developing diseases. Herein, a triboelectric nanogenerator (TENG)‐based smart insole for real‐time gait monitoring is reported. Due to the novel air‐pressure‐driven structural design, the elastic TENG‐based sensors exhibit compelling features including simple fabrication, fast response time, high durability, and excellent mechanical robustness. The TENG‐based sensors can be easily integrated into the conventional insole so that it can convert the mechanical triggering/impact into electrical output. By analyzing such electrical signals, the smart insole could accurately monitor and distinguish various gait patterns in real time, including jump, step, walk, and run. The smart insole could also be used to monitor the abnormality of gait for rehabilitation assessment. In addition, the smart insole can play another important role in healthcare applications, for example, serving as a fall‐down alert system for elder people or patients. This work not only paves a new way for real‐time and long‐term gait monitoring, but also presents a new perspective for the practical applications of remote clinical biomotion analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Flexible triboelectric generator
Fan, F.-R., Tian, Z.-Q., & Lin Wang, Z. (2012) · Nano Energy · doi:10.1016/j.nanoen.2012.01.004 · Cited by 6,705
Muro-de-la-Herran, A., Garcia-Zapirain, B., & Mendez-Zorrilla, A. (2014) · Sensors · doi:10.3390/s140203362 · Cited by 1,172
Gait Analysis Using Wearable Sensors
Tao, W., Liu, T., Zheng, R., & Feng, H. (2012) · Sensors · doi:10.3390/s120202255 · Cited by 1,165
Micro-cable structured textile for simultaneously harvesting solar and mechanical energy
Chen, J., Huang, Y., Zhang, N., Zou, H., Liu, R., Tao, C., Fan, X., & Wang, Z. L. (2016) · Nature Energy · doi:10.1038/nenergy.2016.138 · Cited by 1,060
Self-citationA Review of Accelerometry-Based Wearable Motion Detectors for Physical Activity Monitoring
Yang, C.-C., & Hsu, Y.-L. (2010) · Sensors · doi:10.3390/s100807772 · Cited by 1,058
Reviving Vibration Energy Harvesting and Self-Powered Sensing by a Triboelectric Nanogenerator
Chen, J., & Wang, Z. L. (2017) · Joule · doi:10.1016/j.joule.2017.09.004 · Cited by 1,021
Self-citationDagdeviren, C., Su, Y., Joe, P., Yona, R., Liu, Y., Kim, Y.-S., Huang, Y., Damadoran, A. R., Xia, J., Martin, L. W., et al. (2014) · Nature Communications · doi:10.1038/ncomms5496 · Cited by 987
Recent developments in human motion analysis
Wang, L., Hu, W., & Tan, T. (2003) · Pattern Recognition · doi:10.1016/s0031-3203(02)00100-0 · Cited by 962
On the Electron‐Transfer Mechanism in the Contact‐Electrification Effect
Xu, C., Zi, Y., Wang, A. C., Zou, H., Dai, Y., He, X., Wang, P., Wang, Y., Feng, P., Li, D., et al. (2018) · Advanced Materials · doi:10.1002/adma.201706790 · Cited by 947
Self-citationRadial-arrayed rotary electrification for high performance triboelectric generator
Zhu, G., Chen, J., Zhang, T., Jing, Q., & Wang, Z. L. (2014) · Nature Communications · doi:10.1038/ncomms4426 · Cited by 868
Self-citationNiu, S., Wang, X., Yi, F., Zhou, Y. S., & Wang, Z. L. (2015) · Nature Communications · doi:10.1038/ncomms9975 · Cited by 694
Self-citationAbnormality of Gait as a Predictor of Non-Alzheimer's Dementia
Verghese, J., Lipton, R. B., Hall, C. B., Kuslansky, G., Katz, M. J., & Buschke, H. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa020441 · Cited by 690
Yang, J., Chen, J., Su, Y., Jing, Q., Li, Z., Yi, F., Wen, X., Wang, Z., & Wang, Z. L. (2015) · Advanced Materials · doi:10.1002/adma.201404794 · Cited by 595
Self-citationAstephen, J. L., Deluzio, K. J., Caldwell, G. E., & Dunbar, M. J. (2008) · Journal of Orthopaedic Research · doi:10.1002/jor.20496 · Cited by 561
Triboelectric Nanogenerator Enabled Body Sensor Network for Self-Powered Human Heart-Rate Monitoring
Lin, Z., Chen, J., Li, X., Zhou, Z., Meng, K., Wei, W., Yang, J., & Wang, Z. L. (2017) · ACS Nano · doi:10.1021/acsnano.7b02975 · Cited by 494
Self-citationYang, J., Chen, J., Liu, Y., Yang, W., Su, Y., & Wang, Z. L. (2014) · ACS Nano · doi:10.1021/nn4063616 · Cited by 486
Self-citationLin, Z., Yang, J., Li, X., Wu, Y., Wei, W., Liu, J., Chen, J., & Yang, J. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201704112 · Cited by 416
Self-citationZhang, B., Zhang, L., Deng, W., Jin, L., Chun, F., Pan, H., Gu, B., Zhang, H., Lv, Z., Yang, W., et al. (2017) · ACS Nano · doi:10.1021/acsnano.7b03818 · Cited by 373
Self-citationMethods for gait event detection and analysis in ambulatory systems
Rueterbories, J., Spaich, E. G., Larsen, B., & Andersen, O. K. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.03.007 · Cited by 350
Broadband Vibrational Energy Harvesting Based on a Triboelectric Nanogenerator
Yang, J., Chen, J., Yang, Y., Zhang, H., Yang, W., Bai, P., Su, Y., & Wang, Z. L. (2014) · Advanced Energy Materials · doi:10.1002/aenm.201301322 · Cited by 348
Self-citationKeystroke dynamics enabled authentication and identification using triboelectric nanogenerator array
Wu, C., Ding, W., Liu, R., Wang, J., Wang, A. C., Wang, J., Li, S., Zi, Y., & Wang, Z. L. (2018) · Materials Today · doi:10.1016/j.mattod.2018.01.006 · Cited by 231
Self-citationAn adaptive gyroscope-based algorithm for temporal gait analysis
Greene, B. R., McGrath, D., O’Neill, R., O’Donovan, K. J., Burns, A., & Caulfield, B. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0692-0 · Cited by 199
Redefining the Roles of Sensors in Objective Physical Activity Monitoring
CHEN, K. Y., JANZ, K. F., ZHU, W., & BRYCHTA, R. J. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399bc8 · Cited by 196
Evaluation of an inexpensive depth camera for in-home gait assessment
Stone, E., & Skubic, M. (2011) · Journal of Ambient Intelligence and Smart Environments · doi:10.3233/ais-2011-0124 · Cited by 169
Self-Powered Multifunctional Motion Sensor Enabled by Magnetic-Regulated Triboelectric Nanogenerator
Wu, Z., Ding, W., Dai, Y., Dong, K., Wu, C., Zhang, L., Lin, Z., Cheng, J., & Wang, Z. L. (2018) · ACS Nano · doi:10.1021/acsnano.8b01589 · Cited by 126
Self-citationAll-Elastomer-Based Triboelectric Nanogenerator as a Keyboard Cover To Harvest Typing Energy
Li, S., Peng, W., Wang, J., Lin, L., Zi, Y., Zhang, G., & Wang, Z. L. (2016) · ACS Nano · doi:10.1021/acsnano.6b03926 · Cited by 120
Self-citationWang, P., Liu, R., Ding, W., Zhang, P., Pan, L., Dai, G., Zou, H., Dong, K., Xu, C., & Wang, Z. L. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201705808 · Cited by 120
Self-citationMa, Z. (2011) · Science · doi:10.1126/science.1209094 · Cited by 79
Self-powered wireless optical transmission of mechanical agitation signals
Ding, W., Wu, C., Zi, Y., Zou, H., Wang, J., Cheng, J., Wang, A. C., & Wang, Z. L. (2018) · Nano Energy · doi:10.1016/j.nanoen.2018.03.044 · Cited by 79
Self-citationBae, J., & Tomizuka, M. (2013) · Mechatronics · doi:10.1016/j.mechatronics.2013.06.007 · Cited by 71
Bae, J., Kong, K., Byl, N. N., & Tomizuka, M. (2011) · Journal of Biomechanical Engineering · doi:10.1115/1.4003525 · Cited by 61
Validation of an ear-worn sensor for gait monitoring using a force-plate instrumented treadmill
Atallah, L., Wiik, A., Jones, G. G., Lo, B. P. L., Cobb, J. P., Amis, A. A., & Yang, G. (2011) · Gait & Posture · doi:10.1016/j.gaitpost.2011.11.021 · Cited by 57
Gait and neuromuscular adaptations after using a feedback-based gait monitoring knee brace
Riskowski, J. L. (2010) · Gait & Posture · doi:10.1016/j.gaitpost.2010.05.002 · Cited by 36
Cited by
The Triboelectric Nanogenerator as an Innovative Technology toward Intelligent Sports
Luo, J., Gao, W., & Wang, Z. L. (2021) · Advanced Materials · doi:10.1002/adma.202004178 · Cited by 537
Self-citationZhang, Z., Wen, F., Sun, Z., Guo, X., He, T., & Lee, C. (2022) · Advanced Intelligent Systems · doi:10.1002/aisy.202100228 · Cited by 464
Wearable triboelectric nanogenerators for biomechanical energy harvesting
Zou, Y., Raveendran, V., & Chen, J. (2020) · Nano Energy · doi:10.1016/j.nanoen.2020.105303 · Cited by 351
Triboelectric nanogenerator based self-powered sensor for artificial intelligence
Zhou, Y., Shen, M., Cui, X., Shao, Y., Li, L., & Zhang, Y. (2021) · Nano Energy · doi:10.1016/j.nanoen.2021.105887 · Cited by 344
Lin, Z., Zhang, B., Guo, H., Wu, Z., Zou, H., Yang, J., & Wang, Z. L. (2019) · Nano Energy · doi:10.1016/j.nanoen.2019.103908 · Cited by 341
Self-citation
Metadata
- Authors
- Lin, Z., Wu, Z., Zhang, B., Wang, Y., Guo, H., Liu, G., Chen, C., Chen, Y., Yang, J., & Wang, Z. L.
- Venue
- Advanced Materials Technologies
- Publisher
- Wiley
- Published
- 2018-10-31
- Volume
- 4
- Issue
- 2
- ISSN
- 2365-709X (ISSN-L)
- OpenAlex
- W2899106523
- Cited by
- 256
- References
- 33
- FWCI
- 8.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.