The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Redefining the Roles of Sensors in Objective Physical Activity Monitoring
Open accessAbstract
BACKGROUND: Because physical activity researchers are increasingly using objective portable devices, this review describes the current state of the technology to assess physical activity, with a focus on specific sensors and sensor properties currently used in monitors and their strengths and weaknesses. Additional sensors and sensor properties desirable for activity measurement and best practices for users and developers also are discussed. BEST PRACTICES: We grouped current sensors into three broad categories for objectively measuring physical activity: associated body movement, physiology, and context. Desirable sensor properties for measuring physical activity and the importance of these properties in relationship to specific applications are addressed, and the specific roles of transducers and data acquisition systems within the monitoring devices are defined. Technical advancements in sensors, microcomputer processors, memory storage, batteries, wireless communication, and digital filters have made monitors more usable for subjects (smaller, more stable, and longer running time) and for researchers (less costly, higher time resolution and memory storage, shorter download time, and user-defined data features). FUTURE DIRECTIONS: Users and developers of physical activity monitors should learn about the basic properties of their sensors, such as range, accuracy, and precision, while considering the data acquisition/filtering steps that may be critical to data quality and may influence the desirable measurement outcome(s).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physical Activity Assessment With Accelerometers: An Evaluation Against Doubly Labeled Water
Plasqui, G., & Westerterp, K. R. (2007) · Obesity · doi:10.1038/oby.2007.281 · Cited by 654
Accuracy of the Actiheart for the assessment of energy expenditure in adults
Crouter, S. E., Churilla, J. R., & Bassett, D. R. (2008) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1602766 · Cited by 236
Cited by
Evolution of accelerometer methods for physical activity research
Troiano, R. P., McClain, J. J., Brychta, R. J., & Chen, K. Y. (2014) · British Journal of Sports Medicine · doi:10.1136/bjsports-2014-093546 · Cited by 968
Self-citationA Triboelectric Nanogenerator‐Based Smart Insole for Multifunctional Gait Monitoring
Lin, Z., Wu, Z., Zhang, B., Wang, Y., Guo, H., Liu, G., Chen, C., Chen, Y., Yang, J., & Wang, Z. L. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201800360 · Cited by 256
Wearable Devices for Precision Medicine and Health State Monitoring
Jeong, I. C., Bychkov, D., & Searson, P. C. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2871638 · Cited by 155
Aittasalo, M., Vähä-Ypyä, H., Vasankari, T., Husu, P., Jussila, A.-M., & Sievänen, H. (2015) · BMC Sports Science, Medicine and Rehabilitation · doi:10.1186/s13102-015-0010-0 · Cited by 126
Transfer Learning in Sensor-Based Human Activity Recognition: A Survey
Dhekane, S. G., & Ploetz, T. (2025) · ACM Computing Surveys · doi:10.1145/3717608 · Cited by 42
Metadata
- Authors
- CHEN, K. Y., JANZ, K. F., ZHU, W., & BRYCHTA, R. J.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2012-01
- Volume
- 44
- Issue
- 1S
- Pages
- S13-S23
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2015860097
- Cited by
- 196
- References
- 2
- FWCI
- 12.77
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Redefining the Roles of Sensors in Objective Physical Activity Monitoring. https://app.cochat.ai/papers/10.1249/mss.0b013e3182399bc8
- The paper
- CHEN, K. Y., JANZ, K. F., ZHU, W., & BRYCHTA, R. J. (2012). Redefining the Roles of Sensors in Objective Physical Activity Monitoring. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/mss.0b013e3182399bc8
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.