The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Methods for gait event detection and analysis in ambulatory systems
Abstract
After stroke, hemiparesis is a common problem resulting in very individual needs for walking assistance. Often patients suffer from foot drop, i.e. inability to lift the foot from the ground during the swing phase of walking. Functional electrical stimulation is commonly used to correct foot drop. For all supporting stimulation devices, it is vital to adequately detect the gait events, which is traditionally obtained by a foot switch placed under the heel. To investigate present methods of gait analysis and detection for use in ambulatory rehabilitation systems, we carried out a meta-analysis on research studies. We found various sensors and sensor combinations capable of analyzing gait in ambulatory settings, ranging form simple force based binary switches to complex setups involving multiple inertial sensors and advanced algorithms. However additional effort is needed to minimize donning/doffing efforts, to overcome cosmetical aspects, and to implement those systems into closed loop ambulatory devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A practical gait analysis system using gyroscopes
Tong, K., & Granat, M. H. (1999) · Medical Engineering & Physics · doi:10.1016/s1350-4533(99)00030-2 · Cited by 460
Dejnabadi, H., Jolles, B. M., & Aminian, K. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.851475 · Cited by 286
A review of portable FES-based neural orthoses for the correction of drop foot
Lyons, G. M., Sinkjaer, T., Burridge, J. H., & Wilcox, D. J. (2002) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2002.806832 · Cited by 277
A Reliable Gyroscope-Based Gait-Phase Detection Sensor Embedded in a Shoe Insole
Pappas, I. P. I., Keller, T., Mangold, S., Popovic, M., Dietz, V., & Morari, M. (2004) · IEEE Sensors Journal · doi:10.1109/jsen.2004.823671 · Cited by 221
Clinical Applications of Sensors for Human Posture and Movement Analysis: A Review
Wong, W. Y., Wong, M. S., & Lo, K. H. (2007) · Prosthetics & Orthotics International · doi:10.1080/03093640600983949 · Cited by 193
Cited by
Shull, P. B., Jirattigalachote, W., Hunt, M. A., Cutkosky, M. R., & Delp, S. L. (2014) · Gait & Posture · doi:10.1016/j.gaitpost.2014.03.189 · Cited by 388
Activity Recognition Using a Single Accelerometer Placed at the Wrist or Ankle
MANNINI, A., INTILLE, S. S., ROSENBERGER, M., SABATINI, A. M., & HASKELL, W. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31829736d6 · Cited by 383
Wearable sensor-based real-time gait detection: A systematic review
Prasanth, H., Caban, M., Keller, U., Courtine, G., Ijspeert, A., Vallery, H., & von Zitzewitz, J. (2021) · Sensors · doi:10.3390/s21082727 · Cited by 348
Porciuncula, F., Roto, A. V., Kumar, D., Davis, I., Roy, S., Walsh, C. J., & Awad, L. N. (2018) · PM&R · doi:10.1016/j.pmrj.2018.06.013 · Cited by 300
Bergamini, E., Ligorio, G., Summa, A., Vannozzi, G., Cappozzo, A., & Sabatini, A. (2014) · Sensors · doi:10.3390/s141018625 · Cited by 267
Metadata
- Authors
- Rueterbories, J., Spaich, E. G., Larsen, B., & Andersen, O. K.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2010-05-01
- Volume
- 32
- Issue
- 6
- Pages
- 545-552
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2030254544
- Cited by
- 350
- References
- 5
- FWCI
- 8.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Methods for gait event detection and analysis in ambulatory systems. https://app.cochat.ai/papers/10.1016/j.medengphy.2010.03.007
- The paper
- Rueterbories, J., Spaich, E. G., Larsen, B., & Andersen, O. K. (2010). Methods for gait event detection and analysis in ambulatory systems. Medical Engineering & Physics. https://doi.org/10.1016/j.medengphy.2010.03.007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.