Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index; none of the 31 sources its claims cite is checked for support yet.

Isotopically Encoded Nanotags for Multiplexed Ion Beam Imaging

Open access

Abstract

High‐dimensional profiling of markers and analytes using approaches, such as barcoded fluorescent imaging with repeated labeling and mass cytometry has allowed visualization of biological processes at the single‐cell level. To address limitations of sensitivity and mass‐channel capacity, a nanobarcoding platform is developed for multiplexed ion beam imaging (MIBI) using secondary ion beam spectrometry that utilizes fabricated isotopically encoded nanotags. Use of combinatorial isotope distributions in 100 nm sized nanotags expands the labeling palette to overcome the spectral bounds of mass channels. As a proof‐of‐principle, a four‐digit (i.e., 0001–1111) barcoding scheme is demonstrated to detect 16 variants of 2 H, 19 F, 79/81 Br, and 127 I elemental barcode sets that are encoded in silica nanoparticle matrices. A computational debarcoding method and an automated machine learning analysis approach are developed to extract barcodes for accurate quantification of spatial nanotag distributions in large ion beam imaging areas up to 0.6 mm 2. Isotopically encoded nanotags should boost the performance of mass imaging platforms, such as MIBI and other elemental‐based bioimaging approaches.

Overview

CoChat Summary

TL;DR

The paper develops isotopically encoded silica nanotags for multiplexed ion beam imaging, using combinatorial 2H, 19F, 79/81Br, and 127I labels to create barcodes. It demonstrates proof-of-principle debarcoding of nanotag mixtures with machine learning and reports imaging areas up to 0.6 mm².

Key findings

  • Synthesized ~100 nm silica nanotags (hydrodynamic diameter 105.5 ± 8.1 nm, CV 7.6%) incorporating isotopically enriched scaffolds for 2H, 19F, 79/81Br, and 127I; bare silica showed signal only in 28Si, single-isotope nanotags showed signal only in the respective mass channel, and all-isotope nanotags gave a 1111 barcode.
  • In a three-digit (19F, 79/81Br, 127I) mixture of barcodes 000, 100, 010, 001, 110, 101, and 111 (011 intentionally excluded), 99 nanotags were identified in the field of view by 28Si signal; detected counts were 17, 21, 14, 14, 10, 7, and 16 for 000, 001, 010, 100, 101, 110, and 111, respectively.
  • K-nearest neighbor classification with 3 neighbors achieved precision and recall of 0.87 and above; PCA, t-SNE, and UMAP plots demonstrated accurate debarcoding. The 2H mass channel was excluded from further quantification due to lower sensitivity and an approximately 10-fold dynamic range difference versus halogen channels.
  • Additional 15N, Se, and Te scaffolds were explored; 15N-19F-79/81Br-127I (1111) was distinguished from 19F-79/81Br-127I (0111), while Se and Te were not further used because of mass overlap with Br and I. Stoichiometric ratios 1:1:1 and 0.5:2:1 were separable, and the paper reports theoretical capacities of 32 (2⁵) to 243–1024 barcodes.

Methods

  • Modified Stöber reaction was used to synthesize ~100 nm silica nanoparticles; isotopically encoded nanotags were produced by linking silane-appended isotopically enriched molecular scaffolds (N-ethyl-d5-maleimide, trimethoxy(3,3,3-trifluoropropyl)-silane, eosin-maleimide, and L-thyroxine for 2H, 19F, 79/81Br, and 127I) into the silica matrix.
  • Nanotags were deposited on gold-coated silicon substrates (200 nm Au on 20 nm Ti) and imaged with MIBI/SIMS using a Nano-SIMS device; a large raster scan of 512 × 512 pixels was performed with 10 scans at 5 min per scan.
  • Debarcoding used digital sharpening (Lucy-Richardson), support vector machine and K-nearest neighbor classification, and PCA/t-SNE/UMAP visualization; isotope signals were quantified relative to the 28Si silica matrix signal.

Limitations

  • Stated: the 2H mass channel was excluded from further quantification due to lower sensitivity and ≈10-fold dynamic range difference; Se and Te were not further explored because of mass overlap with Br and I; noncovalent Te incorporation yielded lower signal; the mass cytometry option was not explored; and the MIBI-based sandwich assay method may not be high-throughput.
  • Evident: the study is a proof-of-principle on synthetic nanotags deposited on gold-coated silicon, not on biological samples; no antibody conjugation or analyte detection is demonstrated; and quantitative mixture validation used a three-digit subset (with 011 excluded and 2H excluded), not the full four-digit 16-variant scheme.

Model-written summary. Check it against the paper before relying on it.

Integrity signals

Registry

Crossref · 10.1002/admt.202000098

Cites

36 of 36 references verified0 citation errors · 0 not checkable

Statistics

Nothing to recompute.

Verification

Claims the paper makes

0 Valid · 1 Not valid · 12 Not checked · 41 Own results and interpretations

29 more claims

Create a free account to see all 54 claims and every source verdict.

See all claims — free account
  • It may state two separate claims as one. 14
  • Probably not a substantial claim. 8

Create a free account to see these claims.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

Each contradiction between two passages listed here was confirmed by an independent check.

1 of 1

Citations

Cites

Show all 36 references

Research works printed but not linked: 5

  1. Coskun A. F., 2019, bioRxiv
  2. Rovira‐Clave X., 2019, bioRxiv
  3. Maaten L., 2008, J. Mach. Learn. Res., 9, 2579
  4. L.McInnes J.Healy J.Melville arXiv:180203426 Cs Stat2018.
  5. Caruana R., 2006, Proc. 23rd Int. Conf. Mach. Learn., 161

Cited by

See all 3

Metadata

Authors
Harmsen, S., Coskun, A. F., Ganesh, S., Nolan, G. P., & Gambhir, S. S.
Affiliations
  • Stanford Medicine (US)
  • Georgia Institute of Technology (US)
Corresponding author
  • Coskun, Ahmet F.
  • Nolan, Garry P.
  • Gambhir, Sanjiv S.
Venue
Advanced Materials Technologies
Publisher
Wiley
Published
2020-05-06
Volume
5
Issue
7
ISSN
2365-709X (ISSN-L)
OpenAlex
W3020972568
Cited by
3
References
36
Citations by year
2024: 2 · 2022: 1
FWCI
0.09
Type
journal article
Language
en
Open access
Locations
  • Advanced Materials Technologies (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • Canary Foundation
  • National Science Foundation (ECCS‐1542152)
  • Burroughs Wellcome Fund (K25AI140783)
  • Georgia Institute of Technology (NIH5R01NS08953304, NIH5U54CA14914505, NIH5UH2AR06767603, NIH5R25CA18099304, NIH5R01GM10983604, NIH5R01CA18496804)
  • Department of Chemistry, Vanderbilt University
  • National Institutes of Health (1R01 CA182043‐01A1)
Topics
  • Physical Sciences › Materials Science › Surfaces, Coatings and Films › Ion-surface interactions and analysis
  • Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Metabolomics and Mass Spectrometry Studies
Keywords
MIBI, silica nanoparticles, machine learning, mass cytometry, isotopic labeling

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

A language model drew the claims from the paper on 2026-11-19, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).

A second model labelled each claim on 2026-11-19 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Isotopically Encoded Nanotags for Multiplexed Ion Beam Imaging. https://app.cochat.ai/papers/10.1002/admt.202000098
The paper
Harmsen, S., Coskun, A. F., Ganesh, S., Nolan, G. P., & Gambhir, S. S. (2020). Isotopically Encoded Nanotags for Multiplexed Ion Beam Imaging. Advanced Materials Technologies. https://doi.org/10.1002/admt.202000098

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.