The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Biocompatible and Highly Stretchable PVA/AgNWs Hydrogel Strain Sensors for Human Motion Detection
Abstract
Hydrogel‐based strain sensors have attracted considerable interest for applications such as skin‐like electronics for human motion detection, soft robotics, and human–machine interfaces. However, fabrication of hydrogel strain sensors with desirable mechanical and piezoresistive properties is still challenging. Herein, a biocompatible hydrogel sensor is presented, which is made of polyvinyl alcohol (PVA) nanocomposite with high stretchability up to 500% strain, high mechanical strength of 900 kPa, and electrical conductivity (1.85 S m‐1) comparable to human skin. The hydrogel sensors demonstrate excellent linearity in the whole detection range and great durability under cyclic loading with low hysteresis of 7%. These excellent properties are believed to be contributed by a new bilayer structural design, i.e., a thin, conductive hybrid layer of PVA/silver nanowires (AgNWs) deposited on a pure strong PVA substrate. PVA solution of high concentration is used to fabricate the substrate while the top layer consists of dilute PVA solution so that high content of AgNWs can be dispersed to achieve high electrical conductivity. Together with a rapid response time (0.32 s) and biocompatibility, this new sensor offers great potential as a wearable sensor for epidermal sensing applications, e.g., detecting human joint and muscle movements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Highly Stretchable and Sensitive Strain Sensor Based on Silver Nanowire–Elastomer Nanocomposite
Amjadi, M., Pichitpajongkit, A., Lee, S., Ryu, S., & Park, I. (2014) · ACS Nano · doi:10.1021/nn501204t · Cited by 2,350
Self-citationCai, G., Wang, J., Qian, K., Chen, J., Li, S., & Lee, P. S. (2017) · Advanced Science · doi:10.1002/advs.201600190 · Cited by 921
Ultra-stretchable and skin-mountable strain sensors using carbon nanotubes–Ecoflex nanocomposites
Amjadi, M., Yoon, Y. J., & Park, I. (2015) · Nanotechnology · doi:10.1088/0957-4484/26/37/375501 · Cited by 817
Self-citationPoly(vinyl alcohol) Hydrogel Can Autonomously Self-Heal
Zhang, H., Xia, H., & Zhao, Y. (2012) · ACS Macro Letters · doi:10.1021/mz300451r · Cited by 509
Xia, S., Song, S., Jia, F., & Gao, G. (2019) · Journal of Materials Chemistry B · doi:10.1039/c9tb01039d · Cited by 349
Ultrasensitive and Stretchable Strain Sensors Based on Mazelike Vertical Graphene Network
Wu, S., Peng, S., Han, Z. J., Zhu, H., & Wang, C. H. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b15848 · Cited by 144
Self-citation
Cited by
High‐Stretchability, Ultralow‐Hysteresis ConductingPolymer Hydrogel Strain Sensors for Soft Machines
Shen, Z., Zhang, Z., Zhang, N., Li, J., Zhou, P., Hu, F., Rong, Y., Lu, B., & Gu, G. (2022) · Advanced Materials · doi:10.1002/adma.202203650 · Cited by 574
Metadata
- Authors
- Azadi, S., Peng, S., Moshizi, S. A., Asadnia, M., Xu, J., Park, I., Wang, C. H., & Wu, S.
- Venue
- Advanced Materials Technologies
- Publisher
- Wiley
- Published
- 2020-09-06
- Volume
- 5
- Issue
- 11
- ISSN
- 2365-709X (ISSN-L)
- OpenAlex
- W3084058172
- Cited by
- 169
- References
- 7
- FWCI
- 6.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.