Terahertz Biochemical Molecule‐Specific Sensors
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
The terahertz (THz) spectrum is the focus of basic research in solid‐state physics, chemistry, and materials science as well as applications in next‐generation communications, far‐infrared bolometer, bio/chemical‐sensing, and medical imaging. This wavelength range is at the intersection between photonics and electronics, presenting tremendous opportunities to boost fundamental light–matter interactions enabled by plasmonic nanostructures, metamaterials, and inherent molecular vibrational modes, which occur on time scales of tens of femtoseconds to picoseconds. Recently, engineered metamaterials have presented unique platforms for sensing applications due to their ability to boost such light–matter interactions on the nanoscale and to their spectral selectivity in a wide range from the mid‐infrared to the THz region. Their resonant response can be tuned to that of the intra‐ and intermolecular vibrational modes of target bio/chemical molecules. The emerging fields of highly sensitive and selective mid‐infrared and THz spectroscopies based on metamaterials and plasmonic nanostructures are reviewed. Furthermore, practical applications of these next generation spectroscopic sensors are also discussed, where the sensor platforms will lead to a great impact in the advancement of ultrasmall‐quantity detection of explosives, nondestructive inspection of hazardous materials, food safety, and conformational dynamics of biomolecules in their aqueous environment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Infrared Spectroscopy: Fundamentals and Applications
Stuart, B. H. (2004) · Analytical Techniques in the Sciences · doi:10.1002/0470011149 · Cited by 4,427
Mid-infrared plasmonic biosensing with graphene
Rodrigo, D., Limaj, O., Janner, D., Etezadi, D., García de Abajo, F. J., Pruneri, V., & Altug, H. (2015) · Science · doi:10.1126/science.aab2051 · Cited by 1,462
Resonant Plasmonic and Vibrational Coupling in a Tailored Nanoantenna for Infrared Detection
Neubrech, F., Pucci, A., Cornelius, T. W., Karim, S., García-Etxarri, A., & Aizpurua, J. (2008) · Physical Review Letters · doi:10.1103/physrevlett.101.157403 · Cited by 743
Ultra-sensitive vibrational spectroscopy of protein monolayers with plasmonic nanoantenna arrays
Adato, R., Yanik, A. A., Amsden, J. J., Kaplan, D. L., Omenetto, F. G., Hong, M. K., Erramilli, S., & Altug, H. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0907459106 · Cited by 668
Gas sensing using terahertz time-domain spectroscopy
Mittleman, D. M., Jacobsen, R. H., Neelamani, R., Baraniuk, R. G., & Nuss, M. C. (1998) · Applied Physics B: Lasers and Optics · doi:10.1007/s003400050520 · Cited by 379
Rodrigo, D., Tittl, A., Ait-Bouziad, N., John-Herpin, A., Limaj, O., Kelly, C., Yoo, D., Wittenberg, N. J., Oh, S.-H., Lashuel, H. A., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-04594-x · Cited by 269
Ultrasensitive Detection of Residual Pesticides Using THz Near-Field Enhancement
Lee, D.-K., Kim, G., Kim, C., Jhon, Y. M., Kim, J. H., Lee, T., Son, J.-H., & Seo, M. (2016) · IEEE Transactions on Terahertz Science and Technology · doi:10.1109/tthz.2016.2538731 · Cited by 67
Self-citation
Metadata
- Authors
- Seo, M., & Park, H.
- Venue
- Advanced Optical Materials
- Publisher
- Wiley
- Published
- 2019-07-15
- Volume
- 8
- Issue
- 3
- ISSN
- 2195-1071 (ISSN-L)
- OpenAlex
- W2960780070
- Cited by
- 178
- References
- 7
- FWCI
- 5.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.