Arrowhead Composite Microneedle Patches with Anisotropic Surface Adhesion for Preventing Intrauterine Adhesions
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Biomedical patches are considered as a promising strategy to help tissue repair and regeneration, prevent tissue adhesion, and reduce neighboring friction. Here, novel arrowhead composite microneedle patches (MNPs) are presented with anisotropic surface adhesion and growth factor encapsulation using a heterogeneous template replication approach for endometrium repair and intrauterine adhesions (IUAs) prevention. The arrowhead structures bring about interlocking between the microneedle (MN) tips and tissues, allowing these MNPs to steadily adhere to the tissues. Besides, benefitting from the cytoadhesive needle‐tip material and the antiadhesive base material, these MNPs possess anisotropic surface adhesion and can facilitate cell adhesion on one surface to repair damaged tissues while restrain tissue contact on the other to prevent adverse adhesion. In the meanwhile, the encapsulated growth factor can be delivered through the MNs to the deep tissue, further accelerating tissue repair. Additionally, as the bases are soft and their patterns are highly tunable, the MNPs can change their shapes flexibly to adjust to the irregular morphology of uteri. It is demonstrated that these MNPs show good performances in treating injured endometrium and preventing IUAs of a rat model, indicating their great potential in versatile postoperative adhesion prevention and other clinical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Glucose-responsive insulin patch for the regulation of blood glucose in mice and minipigs
Yu, J., Wang, J., Zhang, Y., Chen, G., Mao, W., Ye, Y., Kahkoska, A. R., Buse, J. B., Langer, R., & Gu, Z. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0508-y · Cited by 604
Self-citation
Cited by
Lyu, S., Dong, Z., Xu, X., Bei, H.-P., Yuen, H.-Y., James Cheung, C.-W., Wong, M.-S., He, Y., & Zhao, X. (2023) · Bioactive Materials · doi:10.1016/j.bioactmat.2023.04.003 · Cited by 266
Bioinspired Adaptable Indwelling Microneedles for Treatment of Diabetic Ulcers
Zhang, X., Gan, J., Fan, L., Luo, Z., & Zhao, Y. (2023) · Advanced Materials · doi:10.1002/adma.202210903 · Cited by 237
Self-citationBee Sting-Inspired Inflammation-Responsive Microneedles for Periodontal Disease Treatment
Song, C., Zhang, X., Lu, M., & Zhao, Y. (2023) · Research · doi:10.34133/research.0119 · Cited by 45
Self-citationLv, H., Xu, R., Xie, X., Liang, Q., Yuan, W., Xia, Y., Ao, X., Tan, S., Zhao, L., Wu, J., et al. (2024) · Acta Biomaterialia · doi:10.1016/j.actbio.2024.06.043 · Cited by 38
Self-citation
Metadata
- Authors
- Zhang, X., Chen, G., Wang, Y., Fan, L., & Zhao, Y.
- Venue
- Advanced Science
- Publisher
- Wiley
- Published
- 2022-02-20
- Volume
- 9
- Issue
- 12
- Pages
- e2104883-e2104883
- ISSN
- 2198-3844 (ISSN-L)
- OpenAlex
- W4212836971
- Cited by
- 75
- References
- 1
- FWCI
- 6.01
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.