The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Flexible 3D Architectured Piezo/Thermoelectric Bimodal Tactile Sensor Array for E‐Skin Application
Abstract
Electronic skin (e‐skin) functions as human–machines interaction interfaces, holding great promise in future personal health monitoring and endowing robots with capability of sense of touch. Despite recent exciting progress in e‐skin research, accurate discrimination of various tactile inputs remains a great challenge yet. A 3D processing technique is demonstrated here combining laser fabrication and screen printing to construct vertically architectured pressure/temperature bimodal active sensor employing all organic functional materials, i.e., piezoelectric poly(vinylidene fluoride‐co‐trifluoroethylene) and thermoelectric polyaniline‐based composites. The sensor transforms pressure and temperature stimuli into two independent electrical signals without interference, exhibiting high temperature sensing sensitivity (109.4 µV K−1) with rapid response time (0.37 s) and superior pressure sensing sensitivity over a wide range (100 Pa to 20 kPa). Finite element analyses further explain the thermal harvesting performance of the sensor. Applications of sensor as e‐skin in various temperature/stress perception scenarios and its stability are demonstrated. Further, a 4 × 4 pixel bimodal tactile sensor array is integrated for the first time, presenting accurate spatial distribution mapping of pressure/temperature signals simultaneously without interference, and functions without external power supply due to its intrinsic working principle. This study thus moves a step toward multifunctional flexible electronics for e‐skin applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641
Binodal, wireless epidermal electronic systems with in-sensor analytics for neonatal intensive care
Chung, H. U., Kim, B. H., Lee, J. Y., Lee, J., Xie, Z., Ibler, E. M., Lee, K., Banks, A., Jeong, J. Y., Kim, J., et al. (2019) · Science · doi:10.1126/science.aau0780 · Cited by 807
Self-citationZhang, F., Zang, Y., Huang, D., Di, C.-A., & Zhu, D. (2015) · Nature Communications · doi:10.1038/ncomms9356 · Cited by 668
Cited by
Multimodal Sensors with Decoupled Sensing Mechanisms
Yang, R., Zhang, W., Tiwari, N., Yan, H., Li, T., & Cheng, H. (2022) · Advanced Science · doi:10.1002/advs.202202470 · Cited by 400
Advances in the design and assembly of flexible thermoelectric device
Cao, T., Shi, X.-L., & Chen, Z.-G. (2023) · Progress in Materials Science · doi:10.1016/j.pmatsci.2022.101003 · Cited by 387
Zhang, Q., Deng, K., Wilkens, L., Reith, H., & Nielsch, K. (2022) · Nature Electronics · doi:10.1038/s41928-022-00776-0 · Cited by 364
Self-citationAge of Flexible Electronics: Emerging Trends in Soft Multifunctional Sensors
Lee, J., Cho, K., & Kim, J. (2024) · Advanced Materials · doi:10.1002/adma.202310505 · Cited by 355
Design and printing of proprioceptive three-dimensional architected robotic metamaterials
Cui, H., Yao, D., Hensleigh, R., Lu, H., Calderon, A., Xu, Z., Davaria, S., Wang, Z., Mercier, P., Tarazaga, P., et al. (2022) · Science · doi:10.1126/science.abn0090 · Cited by 298
Metadata
- Authors
- Zhu, P., Wang, Y., Wang, Y., Mao, H., Zhang, Q., & Deng, Y.
- Venue
- Advanced Energy Materials
- Publisher
- Wiley
- Published
- 2020-08-30
- Volume
- 10
- Issue
- 39
- ISSN
- 1614-6832 (ISSN-L)
- 1614-6840
- OpenAlex
- W3081595318
- Cited by
- 229
- References
- 3
- FWCI
- 7.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Flexible 3D Architectured Piezo/Thermoelectric Bimodal Tactile Sensor Array for E‐Skin Application. https://app.cochat.ai/papers/10.1002/aenm.202001945
- The paper
- Zhu, P., Wang, Y., Wang, Y., Mao, H., Zhang, Q., & Deng, Y. (2020). Flexible 3D Architectured Piezo/Thermoelectric Bimodal Tactile Sensor Array for E‐Skin Application. Advanced Energy Materials. https://doi.org/10.1002/aenm.202001945
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.