The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Design parameters estimation for scale‐up of high‐pressure bubble columns
Abstract
Experiments were carried out in bubble columns for a number of liquids at pressures between 0.1 and 2.0 MPa for two column sizes. Based on the experimental results as well as extensive literature data, the extent of the effect column dimensions have on gas holdup were determined, both at low and high pressures (which is of importance to scale‐up). It was also demonstrated that none of the published empirical gas holdup equations incorporate the influence of gas density accurately. Therefore, a new improved gas hold‐up equation is developed that incorporates the influence of gas and liquid properties with an average error of approximately 10%. Finally, it is also discussed to what extent theinfluence of pressure on other important design parameters such as the interfacial area, the liquid volumetric mass transfer coefficient, and gas and liquid mixing, can be estimated on the basis of empirical equations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The volumetric liquid-phase mass transfer coefficient in bubble columns
Hikita, H., Asai, S., Tanigawa, K., Segawa, K., & Kitao, M. (1981) · The Chemical Engineering Journal · doi:10.1016/0300-9467(81)85006-x · Cited by 148
Cited by
Kantarci, N., Borak, F., & Ulgen, K. O. (2005) · Process Biochemistry · doi:10.1016/j.procbio.2004.10.004 · Cited by 1,057
Wet Oxidation and Catalytic Wet Oxidation
Bhargava, S. K., Tardio, J., Prasad, J., Föger, K., Akolekar, D. B., & Grocott, S. C. (2006) · Industrial & Engineering Chemistry Research · doi:10.1021/ie051059n · Cited by 485
Wet air oxidation: a review of process technologies and aspects in reactor design
Kolaczkowski, S. T., Plucinski, P., Beltran, F. J., Rivas, F. J., & McLurgh, D. B. (1999) · Chemical Engineering Journal · doi:10.1016/s1385-8947(99)00022-4 · Cited by 287
Design and scale-up of the Fischer–Tropsch bubble column slurry reactor
Krishna, R., & Sie, S. T. (2000) · Fuel Processing Technology · doi:10.1016/s0378-3820(99)00128-9 · Cited by 279
Two-Phase Bubble Columns: A Comprehensive Review
Besagni, G., Inzoli, F., & Ziegenhein, T. (2018) · ChemEngineering · doi:10.3390/chemengineering2020013 · Cited by 190
Metadata
- Authors
- Wilkinson, P. M., Spek, A. P., & van Dierendonck, L. L.
- Venue
- AIChE Journal
- Publisher
- Wiley
- Published
- 1992-04
- Volume
- 38
- Issue
- 4
- Pages
- 544-554
- ISSN
- 0001-1541 (ISSN-L)
- 1547-5905
- OpenAlex
- W2139089841
- Cited by
- 393
- References
- 1
- FWCI
- 2.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design parameters estimation for scale‐up of high‐pressure bubble columns. https://app.cochat.ai/papers/10.1002/aic.690380408
- The paper
- Wilkinson, P. M., Spek, A. P., & van Dierendonck, L. L. (1992). Design parameters estimation for scale‐up of high‐pressure bubble columns. AIChE Journal. https://doi.org/10.1002/aic.690380408
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.