Thermocapillary pumping of discrete drops in microfabricated analysis devices
Open accessAbstract
A nonmechanical pumping mechanism, thermocapillary pumping (TCP), is described for moving nanoliter‐ and picoliter‐sized drops of liquid within microfabricated flow channels. In TCP, one end of a single drop is heated to create a surface tension difference between the ends of the drop. The induced surface tension difference causes a capillary pressure difference between the two drop ends and results in drop motion. TCP velocities of up to 20 mm/min were measured for several liquids at temperature differences between 10 and 70°C. An expression developed for TCP velocity yields predictions that agree with experimental velocities within corresponding uncertainty limits. Several techniques for assisting TCP are also suggested when contact angle hysteresis, the major factor limiting TCP velocities, is too large. These techniques include using surface treatments to reduce the contact angle hysteresis, converging channels to offset hysteresis, or an applied pressure to assist in movement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physical chemistry of surfaces
(1998) · Choice Reviews Online · doi:10.5860/choice.35-4499 · Cited by 11,648
Perry's chemical engineers' handbook
(2008) · Choice Reviews Online · doi:10.5860/choice.45-4393 · Cited by 10,121
de Gennes, P. G. (1985) · Reviews of Modern Physics · doi:10.1103/revmodphys.57.827 · Cited by 7,207
(1992) · Choice Reviews Online · doi:10.5860/choice.30-1849 · Cited by 7,135
Perry, J. H. (1950) · Journal of Chemical Education · doi:10.1021/ed027p533.1 · Cited by 3,807
Principles of colloid and surface chemistry
Hiemenz, P. C., & Rajagopalan, R. (1977) · Cited by 3,500
Physical chemistry of surfaces
Taylor, P. (1991) · Colloids and Surfaces · doi:10.1016/0166-6622(91)80262-m · Cited by 2,811
Principles of colloid and surface chemistry
Matijević, E. (1979) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(79)90045-6 · Cited by 2,781
Surface Roughness and Contact Angle.
Wenzel, R. N. (1949) · The Journal of Physical and Colloid Chemistry · doi:10.1021/j150474a015 · Cited by 2,321
The motion of long bubbles in tubes
Bretherton, F. P. (1961) · Journal of Fluid Mechanics · doi:10.1017/s0022112061000160 · Cited by 2,313
Cited by
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
Laser, D. J., & Santiago, J. G. (2004) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/6/r01 · Cited by 1,848
Cho, S. K., Moon, H., & Kim, C.-J. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2002.807467 · Cited by 1,598
Soft Actuators for Small-Scale Robotics
Hines, L., Petersen, K., Lum, G. Z., & Sitti, M. (2017) · Advanced Materials · doi:10.1002/adma.201603483 · Cited by 1,337
Metadata
- Authors
- Sammarco, T. S., & Burns, M. A.
- Venue
- AIChE Journal
- Publisher
- Wiley
- Published
- 1999-02
- Volume
- 45
- Issue
- 2
- Pages
- 350-366
- ISSN
- 0001-1541 (ISSN-L)
- 1547-5905
- OpenAlex
- W1996260084
- Cited by
- 282
- References
- 34
- FWCI
- 10.23
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Thermocapillary pumping of discrete drops in microfabricated analysis devices. https://app.cochat.ai/papers/10.1002/aic.690450215
- The paper
- Sammarco, T. S., & Burns, M. A. (1999). Thermocapillary pumping of discrete drops in microfabricated analysis devices. AIChE Journal. https://doi.org/10.1002/aic.690450215
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.