The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Thermocapillary pumping of discrete drops in microfabricated analysis devices
Open accessAbstract
A nonmechanical pumping mechanism, thermocapillary pumping (TCP), is described for moving nanoliter‐ and picoliter‐sized drops of liquid within microfabricated flow channels. In TCP, one end of a single drop is heated to create a surface tension difference between the ends of the drop. The induced surface tension difference causes a capillary pressure difference between the two drop ends and results in drop motion. TCP velocities of up to 20 mm/min were measured for several liquids at temperature differences between 10 and 70°C. An expression developed for TCP velocity yields predictions that agree with experimental velocities within corresponding uncertainty limits. Several techniques for assisting TCP are also suggested when contact angle hysteresis, the major factor limiting TCP velocities, is too large. These techniques include using surface treatments to reduce the contact angle hysteresis, converging channels to offset hysteresis, or an applied pressure to assist in movement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physical chemistry of surfaces
(1998) · Choice Reviews Online · doi:10.5860/choice.35-4499 · Cited by 11,648
Perry's chemical engineers' handbook
(2008) · Choice Reviews Online · doi:10.5860/choice.45-4393 · Cited by 10,121
de Gennes, P. G. (1985) · Reviews of Modern Physics · doi:10.1103/revmodphys.57.827 · Cited by 7,207
(1992) · Choice Reviews Online · doi:10.5860/choice.30-1849 · Cited by 7,135
Perry, J. H. (1950) · Journal of Chemical Education · doi:10.1021/ed027p533.1 · Cited by 3,807
Principles of colloid and surface chemistry
Hiemenz, P. C., & Rajagopalan, R. (1977) · Cited by 3,500
Physical chemistry of surfaces
Taylor, P. (1991) · Colloids and Surfaces · doi:10.1016/0166-6622(91)80262-m · Cited by 2,811
Principles of colloid and surface chemistry
Matijević, E. (1979) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(79)90045-6 · Cited by 2,781
Surface Roughness and Contact Angle.
Wenzel, R. N. (1949) · The Journal of Physical and Colloid Chemistry · doi:10.1021/j150474a015 · Cited by 2,321
The motion of long bubbles in tubes
Bretherton, F. P. (1961) · Journal of Fluid Mechanics · doi:10.1017/s0022112061000160 · Cited by 2,313
Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a Chip
Harrison, D. J., Fluri, K., Seiler, K., Fan, Z., Effenhauser, C. S., & Manz, A. (1993) · Science · doi:10.1126/science.261.5123.895 · Cited by 1,800
On the Spreading of Liquids on Solid Surfaces: Static and Dynamic Contact Lines
Dussan, E. B. (1979) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fl.11.010179.002103 · Cited by 1,453
The Surface Tension of Pure Liquid Compounds
Jasper, J. J. (1972) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.3253106 · Cited by 1,398
An Integrated Nanoliter DNA Analysis Device
Burns, M. A., Johnson, B. N., Brahmasandra, S. N., Handique, K., Webster, J. R., Krishnan, M., Sammarco, T. S., Man, P. M., Jones, D., Heldsinger, D., et al. (1998) · Science · doi:10.1126/science.282.5388.484 · Cited by 1,299
Self-citation(1995) · Springer eBooks · doi:10.1007/978-94-011-0161-5 · Cited by 1,250
The surface tension of pure liquid compounds
Zettlemoyer, A. C. (1974) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(74)90042-3 · Cited by 931
Ramsay, G. (1998) · Nature Biotechnology · doi:10.1038/nbt0198-40 · Cited by 781
A piezoelectric micropump based on micromachining of silicon
van Lintel, H. T. G., van De Pol, F. C. M., & Bouwstra, S. (1988) · Sensors and Actuators · doi:10.1016/0250-6874(88)87005-7 · Cited by 620
Shoji, S., & Esashi, M. (1994) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/4/4/001 · Cited by 495
DNA chips: An array of possibilities
Marshall, A., & Hodgson, J. (1998) · Nature Biotechnology · doi:10.1038/nbt0198-27 · Cited by 395
Denn, M. M. (1979) · Medical Entomology and Zoology · Cited by 353
Contact Angle Hysteresis: II. Contact Angle Measurements on Rough Surfaces
DETTRE, R. H., & JOHNSON, R. E. (1964) · Advances in Chemistry · doi:10.1021/ba-1964-0043.ch008 · Cited by 316
Electroosmotic pumping and electrophoretic separations for miniaturized chemical analysis systems
Manz, A., Effenhauser, C. S., Burggraf, N., Harrison, D. J., Seiler, K., & Fluri, K. (1994) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/4/4/010 · Cited by 277
Elliott, G. E. P., & Riddiford, A. C. (1967) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(67)90183-x · Cited by 189
Bartell, F. E., & Shepard, J. W. (1953) · The Journal of Physical Chemistry · doi:10.1021/j150503a017 · Cited by 179
Travelling wave-driven microfabricated electrohydrodynamic pumps for liquids
Fuhr, G., Schnelle, T., & Wagner, B. (1994) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/4/4/007 · Cited by 143
Microchannels for applications in liquid dosing and flow-rate measurement
Richter, M., Woias, P., & Weiβ, D. (1997) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(97)01486-6 · Cited by 96
An investigation of the temperature dependence of Poiseuille numbers in microchannel flow
Urbanek, W., ZEMEL, J. N., & Bau, H. H. (1993) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/3/4/009 · Cited by 74
The motion of a mercury index in a capillary tube
Yarnold, G. D. (1938) · Proceedings of the Physical Society · doi:10.1088/0959-5309/50/4/307 · Cited by 52
Microfabrication technologies for integrated nucleic acid analysis.Preprint
Burke, D., Burns, M. A., & Mastrangelo, C. H. (1997) · Genome Research · doi:10.1101/gr.7.3.189 · Cited by 47
Self-citationMicrofluidic flow control using selective hydrophobic patterning
Handique, K., Gogoi, B. P., Burke, D., et al. (1997) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.284515 · Cited by 43
Fluid flow in micron and submicron size channels
Harley, J. C., Bau, H. H., ZEMEL, J. N., & Dominko, V. (2003) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.1989.77954 · Cited by 42
Microfluidic bischemical analysis system
Anderson, R. C., Bogdan, G. J., Bamiv, Z., Dawes, T. D., Winkler, J., & Roy, K. (2002) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.1997.613690 · Cited by 22
Integrated chemical analysis microsystems in space life sciences research
Cefai, J. J., Barrow, D. A., Woias, P., & Muller, E. (1994) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/4/4/002 · Cited by 15
Cited by
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Engineering Flows in Small Devices: Microfluidics Toward a Lab-on-a-Chip
Stone, H. A., Stroock, A. D., & Ajdari, A. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.122124 · Cited by 3,666
Chaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
Laser, D. J., & Santiago, J. G. (2004) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/6/r01 · Cited by 1,848
Cho, S. K., Moon, H., & Kim, C.-J. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2002.807467 · Cited by 1,598
Metadata
- Authors
- Sammarco, T. S., & Burns, M. A.
- Venue
- AIChE Journal
- Publisher
- Wiley
- Published
- 1999-02
- Volume
- 45
- Issue
- 2
- Pages
- 350-366
- ISSN
- 0001-1541 (ISSN-L)
- 1547-5905
- OpenAlex
- W1996260084
- Cited by
- 282
- References
- 34
- FWCI
- 10.23
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.