The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Robust H∞ glucose control in diabetes using a physiological model
Abstract
A robust H∞ controller was developed to deliver insulin via a mechanical pump in Type I diabetic patients. A fundamental nonlinear diabetic patient model was linearized and then reduced to a third‐order linear form for controller synthesis. Uncertainty in the nonlinear model was characterized by up to ±40% variation in eight physiological parameters. A sensitivity analysis identified the three‐parameter set having the most significant effect on glucose and insulin dynamics over the frequency range of interest ω = [0.002, 0.2] (rad/min). This uncertainty was represented in the frequency domain and incorporated in the controller design. Controller performance was assessed in terms of its ability to track a normoglycemic set point (81.1 mg/dL) in response to a 50 g meal disturbance. In the nominal continuous‐time case, the controller maintained glucose concentrations within ±3.3 mg/dL of set point. A controller tuned to accommodate uncertainty yielded a maximum deviation of 17.6 mg/dL for the worst‐case parameter variation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bergman, R. N., Phillips, L. S., & Cobelli, C. (1981) · Journal of Clinical Investigation · doi:10.1172/jci110398 · Cited by 1,640 · cited 2×
“Steil, G. M., J. Murray, R. N. Bergman, and T. A. Buchanan, ‘‘Repeatability of Insulin Sensitivity and Glucose Effectiveness from the Minimal Model Implications for Study Design,’’ Diabetes, 43, Ž .1365 1994 .”
BackgroundCoefficients of normal blood glucose regulation
Bolie, V. W. (1961) · Journal of Applied Physiology · doi:10.1152/jappl.1961.16.5.783 · Cited by 349
SIMON, C., BRANDENBERGER, G., & FOLLENIUS, M. (1987) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-64-4-669 · Cited by 147
Cited by
A System Model of Oral Glucose Absorption: Validation on Gold Standard Data
Man, C. D., Camilleri, M., & Cobelli, C. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.883792 · Cited by 311
MODELING EXERCISE EFFECTS IN TYPE I DIABETIC PATIENTS
Lenart, P. J., & Parker, R. S. (2002) · IFAC Proceedings Volumes · doi:10.3182/20020721-6-es-1901.01350 · Cited by 34
Self-citationComputational study of an augmented minimal model for glycaemia control
Markakis, M. G., Mitsis, G. D., & Marmarelis, V. Z. (2008) · 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2008.4650446 · Cited by 21
Metadata
- Authors
- Parker, R. S., Doyle, F. J., Ward, J. H., & Peppas, N. A.
- Venue
- AIChE Journal
- Publisher
- Wiley
- Published
- 2000-12
- Volume
- 46
- Issue
- 12
- Pages
- 2537-2549
- ISSN
- 0001-1541 (ISSN-L)
- 1547-5905
- OpenAlex
- W2068270626
- Cited by
- 246
- References
- 3
- FWCI
- 1.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Robust H∞ glucose control in diabetes using a physiological model. https://app.cochat.ai/papers/10.1002/aic.690461220
- The paper
- Parker, R. S., Doyle, F. J., Ward, J. H., & Peppas, N. A. (2000). Robust H∞ glucose control in diabetes using a physiological model. AIChE Journal. https://doi.org/10.1002/aic.690461220
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.