Reticulocyte hemoglobin content
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Under normal conditions, reticulocytes are the youngest erythrocytes released from the bone marrow into circulating blood. They mature for 1–3 days within the bone marrow and circulate for 1–2 days before becoming mature erythrocytes. Measurement of cellular hemoglobin concentration has long been reported by automated hematology analyzers as one of the red blood cell indices. The reticulocyte hemoglobin content (CHr or Ret‐He) provides an indirect measure of the functional iron available for new red blood cell production over the previous 3–4 days. Measurement of reticulocyte hemoglobin content in peripheral blood samples is useful for diagnosis of iron deficiency in adults (Mast et al., Blood 2002;99:1489–1491) and children (Brugnara et al., JAMA 1999;281:2225–2230; Ullrich et al., JAMA 2005;294:924–930; Bakr and Sarette, Eur J Pediatr 2006;165:442–445). It provides an early measure of the response to iron therapy increasing within 2–4 days of the initiation of intravenous iron therapy (Brugnara et al., Blood 1994;83:3100–3101). Sequential measurements of reticulocyte hemoglobin content in patients with iron deficiency anemia provide a rapid means for assessing the erythropoietic response to iron replacement therapy (Brugnara et al., Blood 1994;83:3100–3101). It is also an early indicator or iron‐restricted erythropoiesis in patients receiving erythropoietin therapy (Fishbane et al., Kidney Int 1997;52:217–222; Fishbane et al., Kidney Int 2001;60:2406–2411; Mittman et al., Am J Kidney Dis 1997;30:912–922; Tsuchiya et al., Clin Nephrol 2003;59:115–123; Chuang et al., Nephrol Dial Transplant 2003;18:370–377). Thus, reticulocyte hemoglobin content is a recent addition to an expanding list of biomarkers that can be used to differentiate iron deficiency from other causes of anemia. Am. J. Hematol., 2008. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Correction of anemia with epoetin alfa in chronic kidney disease
Singh, A. K., Szczech, L., Tang, K. L., Barnhart, H., Sapp, S., Wolfson, M., & Reddan, D. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa065485 · Cited by 2,762
Serum Transferrin Receptor and Its Ratio to Serum Ferritin in the Diagnosis of Iron Deficiency
Punnonen, K., Irjala, K., & Rajamäki, A. (1997) · Blood · doi:10.1182/blood.v89.3.1052 · Cited by 859
Regulation of Iron Metabolism by Hepcidin
Nemeth, E., & Ganz, T. (2006) · Annual Review of Nutrition · doi:10.1146/annurev.nutr.26.061505.111303 · Cited by 756 · cited 2×
“Hepcidin is an acute phase reactant that prevents absorption of iron from the gastrointestinal tract, its release from hepatic stores, and its recycling within the reticuloendothelial system [15].”
BackgroundLaboratory diagnosis of iron-deficiency anemia: An overview
Guyatt, G. H., Oxman, A. D., Ali, M., Willan, A., McIlroy, W., & Patterson, C. (1992) · Journal of General Internal Medicine · doi:10.1007/bf02598003 · Cited by 564
Hepcidin antimicrobial peptide transgenic mice exhibit features of the anemia of inflammation
Roy, C. N., Mak, H. H., Akpan, I., Losyev, G., Zurakowski, D., & Andrews, N. C. (2007) · Blood · doi:10.1182/blood-2006-10-051755 · Cited by 178
Thomas, L., Franck, S., Messinger, M., Linssen, J., Thomé, M., & Thomas, C. (2005) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2005.207 · Cited by 96
Cited by
Guideline for the laboratory diagnosis of functional iron deficiency
Thomas, D. W., Hinchliffe, R. F., Briggs, C., Macdougall, I. C., Littlewood, T., Cavill, I., & British Committee for Standards in Haematology (2013) · British Journal of Haematology · doi:10.1111/bjh.12311 · Cited by 406
Diagnosis and management of iron deficiency anemia in patients with IBD
Stein, J., Hartmann, F., & Dignass, A. U. (2010) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/nrgastro.2010.151 · Cited by 304
Diagnosis and management of iron deficiency anaemia: a clinical update
Pasricha, S. S., Flecknoe‐Brown, S. C., Allen, K. J., Gibson, P. R., McMahon, L. P., Olynyk, J. K., Roger, S. D., Savoia, H. F., Tampi, R., Thomson, A. R., et al. (2010) · Medical Journal of Australia · doi:10.5694/j.1326-5377.2010.tb04038.x · Cited by 282
Diagnosis and Treatment of Cancer-Related Anemia
Gilreath, J. A., Stenehjem, D. D., & Rodgers, G. M. (2014) · American Journal of Hematology · doi:10.1002/ajh.23628 · Cited by 242
Iron deficiency anemia: diagnosis and management
Clark, S. F. (2009) · Current Opinion in Gastroenterology · doi:10.1097/mog.0b013e32831ef1cd · Cited by 175
Metadata
- Authors
- Mast, A. E., Blinder, M. A., & Dietzen, D. J.
- Venue
- American Journal of Hematology
- Publisher
- Wiley
- Published
- 2007-11-20
- Volume
- 83
- Issue
- 4
- Pages
- 307-310
- ISSN
- 0361-8609 (ISSN-L)
- 1096-8652
- OpenAlex
- W2092750494
- Cited by
- 151
- References
- 6
- FWCI
- 3.59
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reticulocyte hemoglobin content. https://app.cochat.ai/papers/10.1002/ajh.21090
- The paper
- Mast, A. E., Blinder, M. A., & Dietzen, D. J. (2008). Reticulocyte hemoglobin content. American Journal of Hematology. https://doi.org/10.1002/ajh.21090
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.