CoChat

Reliability of B‐mode ultrasound for the measurement of body fat and muscle thickness

Ishida, Y., Carroll, J. F., Pollock, M. L., Graves, J. E., Leggett, S. H. · 1992 · American Journal of Human Biology
Cited by 70

The DOI matches its Crossref record.

Abstract

B‐mode ultrasound was used to measure fat and muscle thicknesses on 30 subjects (17 men, 13 women, age = 20–37 yr) at 14 sites (triceps, biceps, forearm, chest [males only], subscapular, axilla, abdomen, suprailium, lumbar, quadriceps, suprapatellar, hamstrings, medial calf, and posterior calf) on two different days. Quadruplicate photographic images (trials) were printed from a single measurement at each site on each day. Two investigators each measured two of the images from each site. Each thickness was measured to the nearest 0.05 mm with a vernier caliper. Generalizability theory was used to determine the relative contribution of subjects, investigators, days, and trials to the total measurement variability. Subjects accounted for 84–96% of the variance in the muscle measurements and for 79–97% of the variance in the fat measurements. A subjects‐by‐day interaction accounted for 2–13% of the variance in muscle measurements and 2–12% of the variance in fat measurements. The contribution by investigators and trials to the variance was less than 1%. Generalizability coefficients (G) exceeding 0.92 were obtained for all sites for muscle measurements, while G for fat measurements exceeded 0.90 for all but the axilla site (G = 0.88). These results indicate that B‐mode ultrasound is a highly reliable method for the measurement of both fat and muscle thicknesses in young males and females. © 1992 Wiley‐Liss, Inc.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ajhb.1310040410

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 70

Metadata

Authors
Ishida, Y., Carroll, J. F., Pollock, M. L., Graves, J. E., & Leggett, S. H.
Venue
American Journal of Human Biology
Publisher
Wiley
Published
1992-01
Volume
4
Issue
4
Pages
511-520
ISSN
  • 1042-0533 (ISSN-L)
  • 1520-6300
OpenAlex
W2129731297
Cited by
70
References
0
FWCI
0.81
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Reliability of B‐mode ultrasound for the measurement of body fat and muscle thickness. https://app.cochat.ai/papers/10.1002/ajhb.1310040410
The paper
Ishida, Y., Carroll, J. F., Pollock, M. L., Graves, J. E., & Leggett, S. H. (1992). Reliability of B‐mode ultrasound for the measurement of body fat and muscle thickness. American Journal of Human Biology. https://doi.org/10.1002/ajhb.1310040410

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.