Body composition assessment in the infant
Open accessThe DOI matches its Crossref record; 102 of the 102 references it cites were found in a registry or an index.
Abstract
Body composition assessment provides a sharper picture of the human biological response to genetic and environmental influences than measures of body size and weight. Infant body composition is particularly important as a marker of fetal adaptation and developmental programming of subsequent health and disease, but until recently, the range of options for measuring infant body composition was relatively narrow. The purpose of this Toolkit: Methods in Human Biology review is to provide a comprehensive overview of methods of body composition methods currently used in infants 0 to 2 years of age, including anthropometric prediction equations, air displacement plethysmography (ADP), dual energy X‐ray absorptiometry (DXA), bioelectrical impedance analysis (BIA), isotope dilution, and magnetic resonance imaging (MRI). Information on the reliability, validity, and accuracy of the methods is provided. Unique aspects of infant physiology and behavior create challenges for body composition assessment, but this review provides guidance on suitable testing approaches and environments that may aid researchers in this important area of investigation. Am. J. Hum. Biol. 26:291–304, 2014. © 2013 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Body composition of reference children from birth to age 10 years
Fomon, S., Haschke, F., Ziegler, E., & Nelson, S. (1982) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/35.5.1169 · Cited by 1,268 · cited 4×
“1), as shown by existing infant body composition reference data (Butte et al., 2000; Fields et al., 2011; Fomon et al., 1982; Fomon and Nelson, 2002).”
BackgroundMethodInfluentialWells, J. C. K. (2005) · Archives of Disease in Childhood · doi:10.1136/adc.2005.085522 · Cited by 837 · cited 1×
“There have been a number of excellent review articles and book chapters focusing on the assessment of infant body composition published since 2000 (Ellis, 2007; Koo, 2000; Rigo, 2006; Sopher et al., 2005; Wells and Fewtrell, 2006).”
BackgroundRoche, A. F., Heymsfield, S. B., & Lohman, T. G. (2005) · Medical Entomology and Zoology · Cited by 743
Bioelectrical impedance analysis: population reference values for phase angle by age and sex
González, M. C., Barros, A. J. D., Wang, J. P., Heymsfield, S. B., & Pierson, R. N. (2005) · American Journal of Clinical Nutrition · doi:10.1093/ajcn.82.1.49 · Cited by 723 · cited 1×
“…for length) directly from the instrument (Piccoli et al., 1994), without reliance on any assumptions about their relationship to FFM. BIVA reference data are available for both neonates and older infants (Barbosa-Silva et al., 2005; L’Abee et al., 2010; Margutti et al., 2010; Savino et al., 2003).”
BackgroundThe Fetal and Childhood Growth of Persons Who Develop Type 2 Diabetes
Forsén, T., Eriksson, J., Tuomilehto, J., Reunanen, A., Osmond, C., & Barker, D. (2000) · Annals of Internal Medicine · doi:10.7326/0003-4819-133-3-200008010-00008 · Cited by 721 · cited 1×
“…area of human biological research on infant body composition frames it as an early and potentially modifiable risk factor for subsequent metabolic disease and other outcomes (e.g., (Forsen et al., 2000; Ibanez et al., 2006)), and an aspect of the developmental origins of health and disease.”
BackgroundBody composition of the reference fetus.
Ziegler, E. E., O'Donnell, A. M., Nelson, S. E., & Fomon, S. J. (1976) · PubMed · Cited by 713
Neonatal anthropometry: the thin–fat Indian baby. The Pune Maternal Nutrition Study
Yajnik, C. S., Fall, C. H. D., Coyaji, K. J., Hirve, S. S., Rao, S., Barker, D. J. P., Joglekar, C., & Kellingray, S. (2003) · International Journal of Obesity · doi:10.1038/sj.ijo.802219 · Cited by 712 · cited 2×
“…infant body composition assessment, and a variety of combinations of weight, length, American Journal of Human Biology circumferences, and skinfolds can discriminate between fat and lean tissue and subcutaneous fat distribution variation in infants at the group level (e.g., Yajnik et al., 2003).”
BackgroundA new method for monitoring body fluid variation by bioimpedance analysis: The RXc graph
Piccoli, A., Rossi, B., Pillon, L., & Bucciante, G. (1994) · Kidney International · doi:10.1038/ki.1994.305 · Cited by 711 · cited 1×
“BIVA uses R and Xc values (both adjusted for length) directly from the instrument (Piccoli et al., 1994), without reliance on any assumptions about their relationship to FFM. BIVA reference data are available for both neonates and older infants (Barbosa-Silva et al., 2005; L’Abee et al., 2010;…”
Method
Cited by
Shepherd, J. A., Ng, B. K., Sommer, M. J., & Heymsfield, S. B. (2017) · Bone · doi:10.1016/j.bone.2017.06.010 · Cited by 460
Kuriyan, R. (2018) · Indian Journal of Medical Research · doi:10.4103/ijmr.ijmr_1777_18 · Cited by 384
Heymsfield, S. B., Ebbeling, C. B., Zheng, J., Pietrobelli, A., Strauss, B. J., Silva, A. M., & Ludwig, D. S. (2015) · Obesity Reviews · doi:10.1111/obr.12261 · Cited by 111
“The authors extend their appreciation to Drs. Tom Kelly, David Fields, Dale Schoeller, Kori Murray, John Shepherd and ZiMian Wang for their input and critical review of sections in this manuscript.”
BackgroundInfluentialJosefson, J. L., Scholtens, D. M., Kuang, A., Catalano, P. M., Lowe, L. P., Dyer, A. R., Petito, L. C., Lowe, W. L., Metzger, B. E., HAPO Follow-up Study Cooperative Research Group, et al. (2021) · Diabetes Care · doi:10.2337/dc20-2398 · Cited by 55
Metadata
- Authors
- Demerath, E. W., & Fields, D. A.
- Venue
- American Journal of Human Biology
- Publisher
- Wiley
- Published
- 2014-01-15
- Volume
- 26
- Issue
- 3
- Pages
- 291-304
- ISSN
- 1042-0533 (ISSN-L)
- 1520-6300
- OpenAlex
- W1921584718
- Cited by
- 197
- References
- 102
- FWCI
- 5.64
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.