Functional imaging: I. Relative predictive value of intracranial electroencephalography
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Objective: To gain information on the predictive and prognostic value of magnetic source imaging (MSI), 2‐[18F]fluoro‐2‐deoxy‐D‐glucose positron emission tomography (18 FDG‐PET), and ictal single‐photon emission computed tomography (SPECT) as compared with intracranial electroencephalography (ICEEG) localization in epilepsy surgery. Methods: This work was part of a cohort study of epilepsy surgery candidates not sufficiently localized with noninvasive studies. Of 160 patients enrolled over 4 years, 77 completed ICEEG seizure monitoring. Sensitivity, specificity, and predictive values relative to ICEEG were computed for each modality. Results: Seizures were not captured in five patients. Of the 72 diagnostic ICEEG studies, seizure localization results were 74% localized, 10% multifocal, and 17% nonlocalized. Sixty‐one percent were localized to neocortical regions. Depending on patient subgroup pairs, sensitivity ranged from 58 to 64% (MSI), 22 to 40% (PET), and 39 to 48% (SPECT); specificity ranges were 79 to 88% (MSI), 53 to 63% (PET), and 44 to 50% (SPECT). Gains in diagnostic yield were seen only with the combination of MSI and PET or MSI and ictal SPECT. Localization concordance with ICEEG was greatest with MSI, but a significant difference was demonstrated only between MSI and PET. Moderate redundancy was seen between PET and ictal SPECT (κ = 0.452; p = 0.011). Interpretation: Conclusively positive MSI has a high predictive value for seizures localized with ICEEG. Diagnostic gain may be achieved with addition of either PET or ictal SPECT to MSI. Diagnostic values for imaging tests are lower than “true values” because of the limitations of ICEEG as a gold standard. Ann Neurol 2008
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD Initiative.
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., de Vet, H. C. W., et al. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-1-200301070-00010 · Cited by 3,219
Towards complete and accurate reporting of studies of diagnostic accuracy: the STARD initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · BMJ · doi:10.1136/bmj.326.7379.41 · Cited by 3,215
Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD Initiative
Bossuyt, P. M., Reitsma, J. B., Bruns, D. E., Gatsonis, C. A., Glasziou, P. P., Irwig, L. M., Lijmer, J. G., Moher, D., Rennie, D., & de Vet, H. C. W. (2003) · Radiology · doi:10.1148/radiol.2261021292 · Cited by 3,215
Cited by
Diagnostic test utilization in evaluation for resective epilepsy surgery in children
Jayakar, P., Gaillard, W. D., Tripathi, M., Libenson, M. H., Mathern, G. W., Cross, J. H., & The Task Force for Paediatric Epilepsy Surgery, C. F. P. (2014) · Epilepsia · doi:10.1111/epi.12544 · Cited by 223
“PET and SPECT Both interictal FDG-PET and ictal SPECT appear comparable in utility.(19) Both are prone to effects of seizure propagation and thus areas of abnormality be more extensive than the ER.”
BackgroundImaging in the surgical treatment of epilepsy
Duncan, J. S. (2010) · Nature Reviews Neurology · doi:10.1038/nrneurol.2010.131 · Cited by 219
Magnetoencephalography: Basic principles
Singh, S. (2014) · Annals of Indian Academy of Neurology · doi:10.4103/0972-2327.128676 · Cited by 206
“A study by Knowlton et al.[6] explored the predictive and prognostic value of MSI as compared with ICEEG localization in epilepsy surgery.”
Feys, O., Corvilain, P., Aeby, A., Sculier, C., Holmes, N., Brookes, M., Goldman, S., Wens, V., & De Tiège, X. (2022) · Radiology · doi:10.1148/radiol.212453 · Cited by 144
Intrinsic epileptogenicity of cortical tubers revealed by intracranial EEG monitoring
Mohamed, A. R., Bailey, C. A., Freeman, J. L., Maixner, W., Jackson, G. D., & Harvey, A. S. (2012) · Neurology · doi:10.1212/wnl.0b013e3182768923 · Cited by 81
“Direct recording of seizures from extraoperative intracranial EEG monitoring is the gold standard in defining epileptogenic tissue.(9) In TSC, it is employed routinely in only a few centers.”
Background
Metadata
- Authors
- Knowlton, R. C., Elgavish, R. A., Limdi, N., Bartolucci, A., Ojha, B., Blount, J., Burneo, J. G., Ver Hoef, L., Paige, L., Faught, E., Kankirawatana, P., Riley, K., & Kuzniecky, R.
- Venue
- Annals of Neurology
- Publisher
- Wiley
- Published
- 2008-04-15
- Volume
- 64
- Issue
- 1
- Pages
- 25-34
- ISSN
- 0364-5134 (ISSN-L)
- 1531-8249
- OpenAlex
- W2035811672
- Cited by
- 137
- References
- 3
- FWCI
- 7.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.