Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 286

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Quantitative in vivo magnetic resonance imaging of multiple sclerosis at 7 Tesla with sensitivity to iron

Hammond, Kathryn E., Metcalf, Meredith, Carvajal, Lucas, Okuda, Darin T., Srinivasan, Radhika, Vigneron, Dan, Nelson, Sarah J., Pelletier, Daniel·2008·Annals of Neurology

Abstract

Objective: Magnetic resonance imaging at 7 Tesla produces high‐resolution gradient‐echo phase images of patients with multiple sclerosis (MS) that quantify the local field shifts from iron in the basal ganglia and lesions. Phase imaging is easily integrated into clinical examinations because it is a postprocessing technique and does not require additional scanning. The purpose of this study was to quantify local field shifts in MS and to investigate their relation to disease duration and disability status. Methods: Thirty‐two subjects including 19 patients with MS and 13 age‐ and sex‐matched control subjects were scanned at a spatial resolution of up to 195 × 260μm. Data were postprocessed to produce anatomical quantitative phase images of local field shifts, as well as conventional magnitude images. Results: The phase images showed an increased local field in the caudate, putamen, and globus pallidus of patients relative to control subjects (p < 0.01). The local field in the caudate was strongly correlated with disease duration (r2 = 0.77; p < 0.001). Phase images showed contrast in 74% of the 403 lesions, increasing the total lesion count by more than 30% and showing distinct peripheral rings and a close association with vasculature. Interpretation: The increased field in the basal ganglia and correlation with disease duration suggest pathological iron content increases in MS. The peripheral phase rings are consistent with histological data demonstrating iron‐rich macrophages at the periphery of a subset of lesions. The clearly defined vessels penetrating MS lesions should increase our ability to detect focal vascular abnormalities specifically related to demyelinating processes. Ann Neurol 2008;64:707–713

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ana.21582

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 286

Metadata

Authors
Hammond, K. E., Metcalf, M., Carvajal, L., Okuda, D. T., Srinivasan, R., Vigneron, D., Nelson, S. J., & Pelletier, D.
Venue
Annals of Neurology
Publisher
Wiley
Published
2008-12
Volume
64
Issue
6
Pages
707-713
ISSN
  • 0364-5134 (ISSN-L)
  • 1531-8249
OpenAlex
W2020778970
Cited by
286
References
6
FWCI
18.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Quantitative in vivo magnetic resonance imaging of multiple sclerosis at 7 Tesla with sensitivity to iron. https://app.cochat.ai/papers/10.1002/ana.21582
The paper
Hammond, K. E., Metcalf, M., Carvajal, L., Okuda, D. T., Srinivasan, R., Vigneron, D., Nelson, S. J., & Pelletier, D. (2008). Quantitative in vivo magnetic resonance imaging of multiple sclerosis at 7 Tesla with sensitivity to iron. Annals of Neurology. https://doi.org/10.1002/ana.21582

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.