CoChat

High‐frequency oscillations are not better biomarkers of epileptogenic tissues than spikes

Roehri, Nicolas, Pizzo, Francesca, Lagarde, Stanislas, Lambert, Isabelle, Nica, Anca, McGonigal, Aileen, Giusiano, Bernard, Bartolomei, Fabrice, Bénar, Christian‐George · 2018 · Annals of Neurology
Cited by 222

The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.

Abstract

Objective: High‐frequency oscillations (HFOs) in intracerebral EEG (stereoelectroencephalography; SEEG) are considered as better biomarkers of epileptogenic tissues than spikes. How this can be applied at the patient level remains poorly understood. We investigated how well HFOs and spikes can predict epileptogenic regions with a large spatial sampling at the patient level. Methods: We analyzed non‐REM sleep SEEG recordings sampled at 2,048Hz of 30 patients. Ripples (Rs; 80–250Hz), fast ripples (FRs; 250–500Hz), and spikes were automatically detected. Rates of these markers and several combinations—spikes co‐occurring with HFOs or FRs and cross‐rate (Spk⊗HFO)—were compared to a quantified measure of the seizure onset zone (SOZ) by performing a receiver operating characteristic analysis for each patient individually. We used a Wilcoxon signed‐rank test corrected for false‐discovery rate to assess whether a marker was better than the others for predicting the SOZ. Results: A total of 2,930 channels was analyzed (median of 100 channels per patient). The HFOs or any of its variants were not statistically better than spikes. Only one feature, the cross‐rate, was better than all the other markers. Moreover, fast ripples, even though very specific, were not delineating all epileptogenic tissues. Interpretation: At the patient level, the performance of HFOs is weakened by the presence of strong physiological HFO generators. Fast ripples are not sensitive enough to be the unique biomarker of epileptogenicity. Nevertheless, combining HFOs and spikes using our proposed measure—the cross‐rate—is a better strategy than using only one marker. Ann Neurol 2018;83:84–97

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ana.25124

Cites

42 of 42 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 42 references

Cited by

Metadata

Authors
Roehri, N., Pizzo, F., Lagarde, S., Lambert, I., Nica, A., McGonigal, A., Giusiano, B., Bartolomei, F., & Bénar, C.
Venue
Annals of Neurology
Publisher
Wiley
Published
2018-01
Volume
83
Issue
1
Pages
84-97
ISSN
  • 0364-5134 (ISSN-L)
  • 1531-8249
OpenAlex
W2775243036
Cited by
222
References
42
FWCI
11.76
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.