High‐frequency oscillations are not better biomarkers of epileptogenic tissues than spikes
The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
Objective: High‐frequency oscillations (HFOs) in intracerebral EEG (stereoelectroencephalography; SEEG) are considered as better biomarkers of epileptogenic tissues than spikes. How this can be applied at the patient level remains poorly understood. We investigated how well HFOs and spikes can predict epileptogenic regions with a large spatial sampling at the patient level. Methods: We analyzed non‐REM sleep SEEG recordings sampled at 2,048Hz of 30 patients. Ripples (Rs; 80–250Hz), fast ripples (FRs; 250–500Hz), and spikes were automatically detected. Rates of these markers and several combinations—spikes co‐occurring with HFOs or FRs and cross‐rate (Spk⊗HFO)—were compared to a quantified measure of the seizure onset zone (SOZ) by performing a receiver operating characteristic analysis for each patient individually. We used a Wilcoxon signed‐rank test corrected for false‐discovery rate to assess whether a marker was better than the others for predicting the SOZ. Results: A total of 2,930 channels was analyzed (median of 100 channels per patient). The HFOs or any of its variants were not statistically better than spikes. Only one feature, the cross‐rate, was better than all the other markers. Moreover, fast ripples, even though very specific, were not delineating all epileptogenic tissues. Interpretation: At the patient level, the performance of HFOs is weakened by the presence of strong physiological HFO generators. Fast ripples are not sensitive enough to be the unique biomarker of epileptogenicity. Nevertheless, combining HFOs and spikes using our proposed measure—the cross‐rate—is a better strategy than using only one marker. Ann Neurol 2018;83:84–97
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Controlling the False Discovery Rate: A Practical and Powerful Approach to Multiple Testing
Benjamini, Y., & Hochberg, Y. (1995) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1995.tb02031.x · Cited by 109,482 · cited 2×
“We applied a Wilcoxon signed rank test (which is a paired test) to the pAUC of all pairs of markers across patients and corrected for multiple comparisons (False Discovery Rate [39] below 0.”
MethodInfluentialAn introduction to ROC analysis
Fawcett, T. (2006) · Pattern Recognition Letters · doi:10.1016/j.patrec.2005.10.010 · Cited by 21,879 · cited 1×
“because the proportion of epileptic channels in our study is quite low compared to “normal” channels (298 of 2,930).(36) This is also justified in a clinical perspective, because it is more important”
ResultFischl, B. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.01.021 · Cited by 9,526
Selective suppression of hippocampal ripples impairs spatial memory
Girardeau, G., Benchenane, K., Wiener, S. I., Buzsáki, G., & Zugaro, M. B. (2009) · Nature Neuroscience · doi:10.1038/nn.2384 · Cited by 1,560 · cited 2×
“Even though fast ripples (FRs; 250– 500Hz) seem to be always pathological,(16) ripples (Rs; 80– 250Hz) are involved in physiological processes such as memory consolidation in the hippocampus.(17,18) Most previous studies have drawn conclusions about HFOs at the group level.”
BackgroundStaba, R. J., Wilson, C. L., Bragin, A., Fried, I., & Engel, J. (2002) · Journal of Neurophysiology · doi:10.1152/jn.2002.88.4.1743 · Cited by 666 · cited 1×
“For the past decade, research on electrophysiological biomarkers has been fueled by the discovery of interictal high-frequency oscillations (HFOs, 80-500 Hz) [7, 8].”
BackgroundBartolomei, F., Chauvel, P., & Wendling, F. (2008) · Brain · doi:10.1093/brain/awn111 · Cited by 650 · cited 5×
“The classical threshold as defined in the original study [5] is 0.3 but this was determined in TLE patients; the heterogeneity of our patients may explain this slight decrease.”
BackgroundMethodInfluentialSelf-citationDefining epileptogenic networks: Contribution of SEEG and signal analysis
Bartolomei, F., Lagarde, S., Wendling, F., McGonigal, A., Jirsa, V., Guye, M., & Bénar, C. (2017) · Epilepsia · doi:10.1111/epi.13791 · Cited by 637 · cited 1×
“The EI method was shown to be relevant to quantify the epileptogenicity of brain structures [28, 29].”
MethodSelf-citationJacobs, J., LeVan, P., Chander, R., Hall, J., Dubeau, F., & Gotman, J. (2008) · Epilepsia · doi:10.1111/j.1528-1167.2008.01656.x · Cited by 634 · cited 12×
“We set the threshold at 0.25 in order to have a correspondence of approximately 50% between the EIZ and the SOZ.”
BackgroundResultInfluentialThe epileptogenic zone: general principles
Lüders, H. O., Najm, I., Nair, D. R., Widdess‐Walsh, P., & Bingman, W. E. (2006) · Epileptic Disorders · doi:10.1684/j.1950-6945.2006.tb00204.x · Cited by 467 · cited 1×
“The definition of the EZ used in the current study is different from the one of Lüders: “the minimum amount of cortex that must be resected (inactivated or completely disconnected) to produce seizure freedom” [34].”
MethodInterictal high-frequency oscillations (100–500 Hz) in the intracerebral EEG of epileptic patients
Urrestarazu, E., Chander, R., Dubeau, F., & Gotman, J. (2007) · Brain · doi:10.1093/brain/awm149 · Cited by 421 · cited 1×
“For the past decade, research on electrophysiological biomarkers has been fueled by the discovery of interictal high-frequency oscillations (HFOs, 80-500 Hz) [7, 8].”
BackgroundHigh frequency oscillations in intracranial EEGs mark epileptogenicity rather than lesion type
Jacobs, J., LeVan, P., Châtillon, C.-É., Olivier, A., Dubeau, F., & Gotman, J. (2009) · Brain · doi:10.1093/brain/awn351 · Cited by 336 · cited 1×
“They are regarded as being more focal and specific than classical epileptic spikes (Spk) [9, 11, 14].”
BackgroundThe epileptogenic zone: general principles.
Lüders, H. O., Najm, I., Nair, D. R., Widdess‐Walsh, P., & Bingman, W. E. (2006) · PubMed · Cited by 320
Removing interictal fast ripples on electrocorticography linked with seizure freedom in children
Wu, J. Y., Sankar, R., Lerner, J. T., Matsumoto, J. H., Vinters, H. V., & Mathern, G. W. (2010) · Neurology · doi:10.1212/wnl.0b013e3181fc27d0 · Cited by 306 · cited 1×
“These brief and small oscillations visible on intracranial EEG (iEEG) are considered strongly bound to the seizure onset zone (SOZ) [9, 10] and to correlate with surgical outcome [11, 12, 13].”
BackgroundtFast Network Oscillations in the Hippocampal CA1 Region of the Behaving Rat
Csicsvari, T., Hirase, H., Czurkó, A., Mamiya, A., & Buzsáki, G. (1999) · The Journal of Neuroscience · doi:10.1523/jneurosci.19-16-j0001.1999 · Cited by 293 · cited 1×
“The hippocampus is known to produce physiological ripples.(17,39) Addressing the issue of physiological and pathological ripples in order to identify the epileptogenic zone cannot be solved by looking at the overall rate of ripples, especially when regions being known as generators of physiological ripples, such as th…”
BackgroundCrépon, B., Navarro, V., Hasboun, D., Clemenceau, S., Martinerie, J., Baulac, M., Adam, C., & Le Van Quyen, M. (2010) · Brain · doi:10.1093/brain/awp277 · Cited by 286 · cited 11×
“We set the threshold at 0.25 in order to have a correspondence of approximately 50% between the EIZ and the SOZ.”
BackgroundInfluentialRipple classification helps to localize the seizure‐onset zone in neocortical epilepsy
Wang, S., Wang, I. Z., Bulacio, J. C., Mosher, J. C., Gonzalez‐Martinez, J., Alexopoulos, A. V., Najm, I. M., & So, N. K. (2013) · Epilepsia · doi:10.1111/j.1528-1167.2012.03721.x · Cited by 227 · cited 1×
“To better predict the EZ, some teams have proposed to distinguish physiological from pathological HFOs by studying their relationship with spikes [9, 46] with slow waves [43] or with spindles [47].”
BackgroundPathological and physiological high-frequency oscillations in focal human epilepsy
Matsumoto, A., Brinkmann, B. H., Matthew Stead, S., Matsumoto, J., Kucewicz, M. T., Marsh, W. R., Meyer, F., & Worrell, G. (2013) · Journal of Neurophysiology · doi:10.1152/jn.00341.2013 · Cited by 217 · cited 1×
“Other teams have suggested to separate them by clustering HFOs based on features such as frequency, duration, and amplitude.(47,48) The former study managed to differentiate pathological HFOs from normal task-induced HFOs.”
BackgroundThe Bancaud and Talairach view on the epileptogenic zone: a working hypothesis
Kahane, P., Landré, E., Minotti, L., Francione, S., & Ryvlin, P. (2006) · Epileptic Disorders · doi:10.1684/j.1950-6945.2006.tb00206.x · Cited by 212 · cited 2×
“We used the Bancaud and Talairach view on the EZ which is the site of the beginning and of the primary organization of the seizure [1, 2, 3] (independently of the potential surgery).”
BackgroundMethodThe temporopolar cortex plays a pivotal role in temporal lobe seizures
Chabardès, S., Kahane, P., Minotti, L., Tassi, L., Grand, S., Hoffmann, D., & Benabid, A. L. (2005) · Brain · doi:10.1093/brain/awh512 · Cited by 209 · cited 1×
“This is of clinical interest given that the temporal pole can generate seizures along with other mesiotemporal structures.(32,43,44) Figure 1 illustrates this issue with patient 30 where the FR rate is very high in the amygdala and the hippocampus, but not in the mesial temporal pole, even though each structure had hi…”
BackgroundWest, S., Nolan, S. J., Cotton, J., Gandhi, S., Weston, J., Sudan, A., Ramirez, R., & Newton, R. (2015) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010541.pub2 · Cited by 206
Lesion, "Irritative" Zone and Epileptogenic Focus
Talairach, J., & Bancaud, J. (1966) · Stereotactic and Functional Neurosurgery · doi:10.1159/000103937 · Cited by 200 · cited 2×
“We used the Bancaud and Talairach view on the EZ which is the site of the beginning and of the primary organization of the seizure [1, 2, 3] (independently of the potential surgery).”
BackgroundMethodImaging the seizure onset zone with stereo-electroencephalography
David, O., Blauwblomme, T., Job, A.-S., Chabardès, S., Hoffmann, D., Minotti, L., & Kahane, P. (2011) · Brain · doi:10.1093/brain/awr238 · Cited by 197 · cited 1×
“On the one hand, methods have been proposed to better quantify cerebral activity at the onset of the seizure [5, 6].”
MethodLocal and remote epileptogenicity in focal cortical dysplasias and neurodevelopmental tumours
Aubert, S., Wendling, F., Régis, J. M., McGonigal, A., Figarella‐Branger, D., Peragut, J. C., Girard, N. J., Chauvel, P., & Bartoloméi, F. (2009) · Brain · doi:10.1093/brain/awp242 · Cited by 190 · cited 1×
“The EI method was shown to be relevant to quantify the epileptogenicity of brain structures.(27,28) To compute the EI, we used the plugin designed for the open-source software, AnyWave,(29) (available at: http:// meg.”
MethodSelf-citationHaegelen, C., Perucca, P., Châtillon, C., Andrade‐Valença, L., Zelmann, R., Jacobs, J., Collins, D. L., Dubeau, F., Olivier, A., & Gotman, J. (2013) · Epilepsia · doi:10.1111/epi.12075 · Cited by 188 · cited 2×
“They are regarded as being more focal and specific than classical epileptic spikes (Spk) [9, 11, 14].”
BackgroundColombet, B., Woodman, M., Badier, J. M., & Bénar, C. G. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.01.017 · Cited by 163 · cited 3×
“To compute the EI, we used the plugin designed for the open-source software AnyWave [30], available at http://meg.”
MethodInfluentialSelf-citationHuman Intracranial High Frequency Oscillations (HFOs) Detected by Automatic Time-Frequency Analysis
Burnos, S., Hilfiker, P., Sürücü, O., Scholkmann, F., Krayenbühl, N., Grünwald, T., & Sarnthein, J. (2014) · PLoS ONE · doi:10.1371/journal.pone.0094381 · Cited by 158 · cited 1×
“With the emergence of automated HFO detectors, the number of studied channels per patient increased but, since existing detectors were not designed to detect both HFOs and spikes, information about spikes were lost [10, 20, 21].”
BackgroundResidual fast ripples in the intraoperative corticogram predict epilepsy surgery outcome
Klooster, M. A. V. ’., van Klink, N. E. C., Leijten, F. S. S., Zelmann, R., Gebbink, T. A., Gosselaar, P. H., Braun, K. P. J., Huiskamp, G. J. M., & Zijlmans, M. (2015) · Neurology · doi:10.1212/wnl.0000000000001727 · Cited by 153 · cited 3×
“This poor performance seems to go against previous publications [9, 13].”
BackgroundResultTrends in epilepsy surgery: stable surgical numbers despite increasing presurgical volumes
Cloppenborg, T., May, T. W., Blümcke, I., Grewe, P., Hopf, L. J., Kalbhenn, T., Pfäfflin, M., Polster, T., Schulz, R., Woermann, F. G., et al. (2016) · Journal of Neurology Neurosurgery & Psychiatry · doi:10.1136/jnnp-2016-313831 · Cited by 145 · cited 1×
“This relatively low number of patients operated is in line with a recent study [24].”
ResultImproving the identification of High Frequency Oscillations
Zelmann, R., Zijlmans, M., Jacobs, J., Châtillon, C.-E., & Gotman, J. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.05.029 · Cited by 138 · cited 1×
“HFO and spike rates even though these rates may vary over time.(26) The analysis was performed in a bipolar montage.”
BackgroundBartoloméi, F., Cosandier‐Rimélé, D., McGonigal, A., Aubert, S., Régis, J. M., Gavaret, M., Wendling, F., & Chauvel, P. (2010) · Epilepsia · doi:10.1111/j.1528-1167.2010.02690.x · Cited by 137 · cited 2×
“Channels exhibiting EI values above 0.2-0.3 are said to be epileptogenic [5, 15, 31, 32, 33].”
BackgroundInfluentialSelf-citationRoehri, N., Lina, J., Mosher, J. C., Bartoloméi, F., & Bénar, C. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2556425 · Cited by 136
Self-citationvon Ellenrieder, N., Frauscher, B., Dubeau, F., et al. (2016) · Epilepsia · doi:10.1111/epi.13380 · Cited by 135
Navarrete, M., Alvarado‐Rojas, C., Quyen, M. L. V., & Valderrama, M. (2016) · PLoS ONE · doi:10.1371/journal.pone.0158276 · Cited by 135 · cited 1×
“Delphos showed constant high precision, i.e. the detections were almost always correct, and the highest sensitivity compared to the 4 other detectors from the Ripplelab Toolbox [36].”
ResultBartoloméi, F., Trébuchon, A., Bonini, F., Lambert, I., Gavaret, M., Woodman, M., Giusiano, B., Wendling, F., & Bénar, C. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.10.029 · Cited by 128 · cited 2×
“Channels exhibiting EI values above 0.2-0.3 are said to be epileptogenic [5, 15, 31, 32, 33].”
BackgroundInfluentialSelf-citationHigh Frequency Oscillations and spikes: Separating real HFOs from false oscillations
Amiri, M., Lina, J., Pizzo, F., & Gotman, J. (2015) · Clinical Neurophysiology · doi:10.1016/j.clinph.2015.04.290 · Cited by 123 · cited 1×
“We acknowledge that detecting HFOs superimposed on spikes is challenging especially when these events overlap both in time and frequency [41], which could require further developments such as spike removal [42].”
BackgroundSelf-citationTemporal lobe epilepsy and hippocampal sclerosis: Lessons from depth EEG recordings
Kahane, P., & Bartoloméi, F. (2010) · Epilepsia · doi:10.1111/j.1528-1167.2009.02448.x · Cited by 104 · cited 1×
“This is of clinical interest given that the temporal pole can generate seizures along with other mesiotemporal structures.(32,43,44) Figure 1 illustrates this issue with patient 30 where the FR rate is very high in the amygdala and the hippocampus, but not in the mesial temporal pole, even though each structure had hi…”
BackgroundNetwork oscillations modulate interictal epileptiform spike rate during human memory
Matsumoto, J. Y., Stead, M., Kucewicz, M. T., Matsumoto, A. J., Peters, P. A., Brinkmann, B. H., Danstrom, J. C., Goerss, S. J., Marsh, W. R., Meyer, F. B., et al. (2013) · Brain · doi:10.1093/brain/awt159 · Cited by 94 · cited 1×
“Other teams have suggested to separate them by clustering HFOs based on features such as frequency, duration, amplitude [48, 49].”
BackgroundMalinowska, U., Bergey, G. K., Harezlak, J., & Jouny, C. C. (2014) · Clinical Neurophysiology · doi:10.1016/j.clinph.2014.11.007 · Cited by 88 · cited 1×
“Other teams have suggested to separate them by clustering HFOs based on features such as frequency, duration, and amplitude.(47,48) The former study managed to differentiate pathological HFOs from normal task-induced HFOs.”
BackgroundConundrums of High-Frequency Oscillations (80–800 Hz) in the Epileptic Brain
de la Prida, L. M., Staba, R. J., & Dian, J. A. (2015) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0000000000000150 · Cited by 86 · cited 4×
“The bipolar montage could possibly hinder HFO visibility [16].”
BackgroundInfluentialOn the use of partial area under the ROC curve for comparison of two diagnostic tests
Ma, H., Bandos, A. I., & Gur, D. (2015) · Biometrical Journal · doi:10.1002/bimj.201400023 · Cited by 75
Bruder, J. C., Dümpelmann, M., Piza, D. L., Mader, M., Schulze‐Bonhage, A., & Van, J. J.-L. (2017) · International Journal of Neural Systems · doi:10.1142/s0129065717500113 · Cited by 66 · cited 1×
“To better predict the EZ, some teams have proposed to distinguish physiological from pathological HFOs by studying their relationship with spikes [9, 46] with slow waves [43] or with spindles [47].”
BackgroundMarchi, A., Bonini, F., Lagarde, S., McGonigal, A., Gavaret, M., Scavarda, D., Carron, R., Aubert, S., Villeneuve, N., Villalon, S. M., et al. (2016) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2016.06.014 · Cited by 47 · cited 1×
“Channels exhibiting EI values above 0.2-0.3 are said to be epileptogenic [5, 15, 31, 32, 33].”
BackgroundInfluentialSelf-citation
Cited by
Epilepsy biomarkers – Toward etiology and pathology specificity
Pitkänen, A., Ekolle Ndode-Ekane, X., Lapinlampi, N., & Puhakka, N. (2019) · Neurobiology of Disease · doi:10.1016/j.nbd.2018.05.007 · Cited by 172
Metadata
- Authors
- Roehri, N., Pizzo, F., Lagarde, S., Lambert, I., Nica, A., McGonigal, A., Giusiano, B., Bartolomei, F., & Bénar, C.
- Venue
- Annals of Neurology
- Publisher
- Wiley
- Published
- 2018-01
- Volume
- 83
- Issue
- 1
- Pages
- 84-97
- ISSN
- 0364-5134 (ISSN-L)
- 1531-8249
- OpenAlex
- W2775243036
- Cited by
- 222
- References
- 42
- FWCI
- 11.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.