Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 372

The DOI matches its Crossref record.

Occipital lobe epilepsy: Clinical characteristics, seizure spread patterns, and results of surgery

Williamson, P. D., Thadani, V. M., Darcey, T. M., Spencer, D. D., Spencer, S. S., Mattson, R. H.·1992·Annals of Neurology

Abstract

Twenty‐five patients with occipital lobe seizure origin were retrospectively evaluated to determine clinical seizure characteristics and electroencephalographic manifestations. Certain symptoms and signs served to identify occipital lobe origin in 22 (88%). These included elementary visual hallucinations, ictal amaurosis, eye movement sensations, early forced blinking or eyelid flutter, and visual field deficits. Eye or head deviation, or both, was observed frequently and was contralateral to the side of seizure origin in 13, but 3 patients exhibited ipsilateral deviation in some or all their seizures. After the initial signs and symptoms, clinical seizure characteristics resembled those of seizures originating elsewhere. Seizures typical of temporal lobe origin with loss of contact and various types of automatic, semipurposeful activity occurred in 11 patients. Seizures in 3 patients exhibited asymmetrical tonic or focal clonic motor patterns characteristic of frontal lobe seizures. Eleven of the 25 patients had, on two occasions, two or more distinctly different seizure types. Scalp electroencephalographic findings were seldom helpful for occipital lobe localization and were frequently misleading. Intracranial electroencephalographic recording correctly identified occipital lobe seizure origin in most, but not all, patients who had such studies. Intracranial electroencephalic recording also proved the variability in clinical seizure characteristics was related to different seizure spread patterns, medially or laterally above and below the sylvian fissure, both ipsilateral and contralateral to the occipital lobe of seizure origin. Eighteen patients had occipital lobe lesions detected with computed tomographic or magnetic resonance imaging scans or both. Resection of the lesions in 16 patients produced excellent results in 14 (88%). Five patients had temporal lobectomies, with good results in 3, but poor results in 2. Two patients with unlocalized seizures had complete section of the corpus callosum, 1 with a good result and the other with a poor result.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ana.410310103

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Metadata

Authors
Williamson, P. D., Thadani, V. M., Darcey, T. M., Spencer, D. D., Spencer, S. S., & Mattson, R. H.
Venue
Annals of Neurology
Publisher
Wiley
Published
1992-01
Volume
31
Issue
1
Pages
3-13
ISSN
  • 0364-5134 (ISSN-L)
  • 1531-8249
OpenAlex
W2036183924
Cited by
372
References
0
FWCI
7.51
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Occipital lobe epilepsy: Clinical characteristics, seizure spread patterns, and results of surgery. https://app.cochat.ai/papers/10.1002/ana.410310103
The paper
Williamson, P. D., Thadani, V. M., Darcey, T. M., Spencer, D. D., Spencer, S. S., & Mattson, R. H. (1992). Occipital lobe epilepsy: Clinical characteristics, seizure spread patterns, and results of surgery. Annals of Neurology. https://doi.org/10.1002/ana.410310103

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.