Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 1,004

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Acute human stroke studied by whole brain echo planar diffusion‐weighted magnetic resonance imaging

Warach, Steven, Gaa, Jochen, Siewert, Bettina, Wielopolski, Piotr, Edelman, Robert R.·1995·Annals of Neurology

Abstract

Our purpose was to use whole brain echo planar magnetic resonance imaging (MRI) to identify and characterize diffusion abnormalities in acute cerebral ischemia. We studied 40 patients as early as 3 hours after onset of signs and symptoms of cerebral ischemia. Diffusion‐weighted imaging (DWI) of the entire brain could be completed in 3 seconds or, using seven different diffusion sensitivities (maximum b=1,271 sec/2), in 48 seconds. Measurements and synthetic maps were made of apparent diffusion coefficients (ADC), a physiological parameter that characterizes the self‐diffusion of water in tissue. Early ischemic lesions were identified with DWI as hyperintense regions of decreased ADC in all patients who subsequently developed infarction, before changes were evident on conventional MRI in cases studied earlier than 6 hours after onset of ischemic symptoms. Lesions as small as 4 mm in diameter were identified. The extent of lesions within white matter was best defined by controlling for the anisotropic effect of axonal orientation. The mean ADC (± SD) for control regions in the 36 patients was 9.15 (± 2.91) × 10−4 mm 2/sec. Mean ADC of ischemic regions was 56% of control values at 6 hours or less and stayed significantly reduced for 3 to 4 days after onset of ischemia. The relative ADC increased progressively over time to be pseudonormalized at 5 to 10 days and elevated in the chronic state, making the distinction of acute lesions adjacent to chronic infarcts readily apparent. DWI with echo planar imaging measures a unique physiological parameter that is sensitive to ischemic changes before conventional MRI. Its potential role in the quantitative study of human stroke pathophysiology and therapeutics is the subject of further investigation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ana.410370214

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Warach, S., Gaa, J., Siewert, B., Wielopolski, P., & Edelman, R. R.
Venue
Annals of Neurology
Publisher
Wiley
Published
1995-02
Volume
37
Issue
2
Pages
231-241
ISSN
  • 0364-5134 (ISSN-L)
  • 1531-8249
OpenAlex
W2109411133
Cited by
1,004
References
3
FWCI
53.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.