Near‐Infrared Fluorescent Molecular Probe for Sensitive Imaging of Keloid
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Early detection of skin diseases is imperative for their effective treatment. However, fluorescence molecular probes that allow this are rare. The first activatable near‐infrared (NIR) fluorescent molecular probe is reported for sensitive imaging of keloid cells, skin cells from abnormal scar fibrous lesions. As keloid cells have high expression levels of fibroblast activation protein‐alpha (FAPα), the probe (FNP1) is designed to have a caged NIR dye and a FAPα‐cleavable peptide substrate linked by a self‐immolative segment. FNP1 can quickly and specifically turn on its fluorescence at 710 nm by 45‐fold in the presence of FAPα, allowing it to effectively recognize keloid cells from normal skin cells. Integration of FNP1 with a simple microneedle‐assisted topical application enables sensitive detection of keloid cells in metabolically‐active human skin tissue with a theoretical limit of detection down to 20 000 cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bayat, A., McGrouther, D. A., & Ferguson, M. W. J. (2003) · BMJ · doi:10.1136/bmj.326.7380.88 · Cited by 608
Ashcroft, G. S., Greenwell-Wild, T., Horan, M. A., Wahl, S. M., & Ferguson, M. W. J. (1999) · The American Journal of Pathology · doi:10.1016/s0002-9440(10)65217-0 · Cited by 420
Hsu, C.-K., Tzeng, S.-Y., Yang, C.-C., Lee, J. Y.-Y., Huang, L. L.-H., Chen, W.-R., Hughes, M., Chen, Y.-W., Liao, Y.-K., & Tseng, S.-H. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.000390 · Cited by 45
Research works printed but not linked: 20
- 10.1038/nature21056 · DOI · Paper page
- 10.1371/journal.pmed.0040234 · DOI · Paper page
- 10.1016/j.burns.2013.09.029 · doi:10.1016/j.burns.2013.09.029
- 10.1097/01.prs.0000195073.73580.46 · DOI · Paper page
- 10.1021/cr900236h · DOI · Paper page
- 10.1021/acs.bioconjchem.6b00641 · DOI · Paper page
- 10.1038/nchem.480 · DOI · Paper page
- 10.1002/anie.201600753 · DOI
- 10.1002/ange.201600753 · DOI
- 10.1038/jid.2012.389 · DOI
- 10.1007/s10585-011-9392-x · DOI
- 10.1021/ja305802v · DOI · Paper page
- 10.1039/C5CC09976E · DOI · Paper page
- 10.1002/chem.201702210 · DOI
- 10.1023/A:1011355300910 · doi:10.1023/a:1011355300910
- 10.1021/bc300278r · DOI · Paper page
- 10.1002/smll.201300600 · DOI
- 10.4161/cbt.6.11.4874 · DOI · Paper page
- 10.1016/j.molonc.2015.08.001 · DOI · Paper page
- 10.1089/ten.tec.2013.0335 · DOI · Paper page
Cited by
Recent progresses in small-molecule enzymatic fluorescent probes for cancer imaging
Liu, H.-W., Chen, L., Xu, C., Li, Z., Zhang, H., Zhang, X.-B., & Tan, W. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00862g · Cited by 948
Self-citationEffective Wound Healing Enabled by Discrete Alternative Electric Fields from Wearable Nanogenerators
Long, Y., Wei, H., Li, J., Yao, G., Yu, B., Ni, D., Gibson, A. L., Lan, X., Jiang, Y., Cai, W., et al. (2018) · ACS Nano · doi:10.1021/acsnano.8b07038 · Cited by 397
Activity‐Based NIR Enzyme Fluorescent Probes for the Diagnosis of Tumors and Image‐Guided Surgery
Li, H., Kim, D., Yao, Q., Ge, H., Chung, J., Fan, J., Wang, J., Peng, X., & Yoon, J. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202009796 · Cited by 363
Hemicyanine‐Based Near‐Infrared Activatable Probes for Imaging and Diagnosis of Diseases
Zeng, Z., Liew, S. S., Wei, X., & Pu, K. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202107877 · Cited by 359
Self-citationZhen, X., Zhang, J., Huang, J., Xie, C., Miao, Q., & Pu, K. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201803321 · Cited by 352
Self-citation
Metadata
- Authors
- Miao, Q., Yeo, D. C., Wiraja, C., Zhang, J., Ning, X., Xu, C., & Pu, K.
- Venue
- Angewandte Chemie
- Publisher
- Wiley
- Published
- 2018-01-05
- Volume
- 130
- Issue
- 5
- Pages
- 1270-1274
- ISSN
- 0044-8249 (ISSN-L)
- 1521-3757
- OpenAlex
- W4234223126
- Cited by
- 57
- References
- 3
- FWCI
- 4.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).