The DOI matches its Crossref record; 129 of the 129 references it cites were found in a registry or an index.
Electrospray Mass Spectrometry of Biomacromolecular Complexes with Noncovalent Interactions—New Analytical Perspectives for Supramolecular Chemistry and Molecular Recognition Processes
Abstract
The development of “soft” ionization methods in recent years has enabled substantial progress in the mass spectrometric characterization of macromolecules, in particular important biopolymers such as proteins and nucleic acids. In contrast to the still existing limitations for the determination of molecular weights by other ionization methods such as fast atom bombardment and plasma desorption, electrospray ionization (ESI) and matrix‐assisted laser desorption have provided a breakthrough to macromolecules larger than 100 kDa. Whereas these methods have been successfully applied to determine the molecular weight and primary structure of biopolymers, the recently discovered direct characterization by ESI‐MS of complexes containing noncovalent interactions (“noncovalent complexes”) opens new perspectives for supramolecular chemistry and analytical biochemistry. Unlike other ionization methods ESI‐MS can be performed in homogeneous solution and under nearly physiological conditions of pH, concentration, and temperature. ESI mass spectra of biopolymers, particularly proteins, exhibit series of multiply charged macromolecular ions with charge states and distributions (“charge structures”) characteristic of structural states in solution, which enable a differentiation between native and denatured tertiary structures. In the first part of this article, fundamental principles, the present knowledge about ion formation mechanism(s) of ESI‐MS, the relations between tertiary structures in solution and charge structures of macro‐ions in the gas phase, and experimental preconditions for the identification of noncovalent complexes are described. The hitherto successful applications to the identification of enzyme–substrate and –inhibitor complexes, supramolecular protein–and protein–nucleotide complexes, double‐stranded polynucleotides, as well as synthetic self‐assembled complexes demonstrate broad potential for the direct analysis of specific noncovalent interactions. The present results suggest new applications for the characterization of supramolecular structures and molecular recognition processes that previously have not been amenable to mass spectrometry; for example, the sequence‐specific oligomerization of polypeptides, antigen–antibody complexes, enzyme–and receptor–ligand interactions, and the evaluation of molecular specificity in combinatorial syntheses and self‐assembled systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
NMR with Proteins and Nucleic Acids
Wüthrich, K. (1986) · Europhysics News · doi:10.1051/epn/19861701011 · Cited by 7,989
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637
Lehn, J. (1990) · Angewandte Chemie International Edition in English · doi:10.1002/anie.199013041 · Cited by 3,027
Allele-specific motifs revealed by sequencing of self-peptides eluted from MHC molecules
Falk, K., Rötzschke, O., Stevanovié, S., Jung, G., & Rammensee, H.-G. (1991) · Nature · doi:10.1038/351290a0 · Cited by 2,411
Antisense oligonucleotides: a new therapeutic principle
Uhlmann, E., & Peyman, A. (1990) · Chemical Reviews · doi:10.1021/cr00102a001 · Cited by 1,640
Dole, M., Mack, L. L., Hines, R. L., Mobley, R. C., Ferguson, L. D., & Alice, M. B. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670391 · Cited by 1,613
Single-Chain Antigen-Binding Proteins
Bird, R. E., Hardman, K. D., Jacobson, J. W., Johnson, S., Kaufman, B. M., Lee, S.-M., Lee, T., Pope, S. H., Riordan, G. S., & Whitlow, M. (1988) · Science · doi:10.1126/science.3140379 · Cited by 1,502
Ringsdorf, H., Schlarb, B., & Venzmer, J. (1988) · Angewandte Chemie International Edition in English · doi:10.1002/anie.198801131 · Cited by 1,454
X-Ray Structure of the GCN4 Leucine Zipper, a Two-Stranded, Parallel Coiled Coil
O'Shea, E. K., Klemm, J. D., Kim, P. S., & Alber, T. (1991) · Science · doi:10.1126/science.1948029 · Cited by 1,440
Cited by
Helicates as Versatile Supramolecular Complexes
Piguet, C., Bernardinelli, G., & Hopfgartner, G. (1997) · Chemical Reviews · doi:10.1021/cr960053s · Cited by 1,711
Studying noncovalent protein complexes by electrospray ionization mass spectrometry
Loo, J. A. (1997) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1997)16:1<1::aid-mas1>3.0.co;2-l · Cited by 1,182
Banerjee, S., & Mazumdar, S. (2012) · International Journal of Analytical Chemistry · doi:10.1155/2012/282574 · Cited by 662
Investigation of intact protein complexes by mass spectrometry
Heck, A. J. R., & van den Heuvel, R. H. H. (2004) · Mass Spectrometry Reviews · doi:10.1002/mas.10081 · Cited by 583
Daniel, J. M., Friess, S. D., Rajagopalan, S., Wendt, S., & Zenobi, R. (2002) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(02)00585-7 · Cited by 475
Loo, J. A. (2000) · International Journal of Mass Spectrometry · doi:10.1016/s1387-3806(00)00298-0 · Cited by 444
Peptides and Proteins in the Vapor Phase
Jarrold, M. F. (2000) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.51.1.179 · Cited by 361
Hoaglund-Hyzer, C. S., Counterman, A. E., & Clemmer, D. E. (1999) · Chemical Reviews · doi:10.1021/cr980139g · Cited by 320
The benefits (and misfortunes) of SDS in top-down proteomics
Kachuk, C., & Doucette, A. A. (2018) · Journal of Proteomics · doi:10.1016/j.jprot.2017.03.002 · Cited by 39
Metadata
- Authors
- Przybylski, M., & Glocker, M. O.
- Venue
- Angewandte Chemie International Edition in English
- Publisher
- Wiley
- Published
- 1996-05-03
- Volume
- 35
- Issue
- 8
- Pages
- 806-826
- ISSN
- 0570-0833 (ISSN-L)
- OpenAlex
- W2120463093
- Cited by
- 351
- References
- 129
- FWCI
- 22.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.