The DOI matches its Crossref record.
Molecular Beams of Macroions
Abstract
By means of electrospraying a dilute polymer solution into an evaporation chamber, negative macroions can be produced and a molecular beam formed by sampling the gaseous mixture of macroions, solvent, and nitrogen molecules with a nozzle-skimmer system of the Kantrowitz–Gray type. The macroion current can be detected by a Faraday cage after the light ions have been repelled from the beam by negative voltages on a repeller grid. Theoretical repeller voltages which best agree with the observed are those calculated by assuming a macroion velocity within 2% of the estimated supersonic beam velocity of 743 m sec−1. Polystyrene macroions of 51 000 weight-average amu tend to form dimers and trimers in the beam while larger polystyrene macroions of 411 000 weight-average amu appear mostly to be multiply charged single species. The results demonstrate that definite mass/charge states can be formed by the electrospray technique, that a considerable monochromatization of macroion velocities in the beam takes place, and that the macroions become highly concentrated relative to low-molecular-weight solvent and nitrogen ions during the transit time in the supersonic beam.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
New developments in biochemical mass spectrometry: electrospray ionization
Smith, R. D., Loo, J. A., Edmonds, C. G., Barinaga, C. J., & Udseth, H. R. (1990) · Analytical Chemistry · doi:10.1021/ac00208a002 · Cited by 1,051
Electrospray: From ions in solution to ions in the gas phase, what we know now
Kebarle, P., & Verkerk, U. H. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20247 · Cited by 905
Dongré, A. R., Jones, J. L., Somogyi, Á., & Wysocki, V. H. (1996) · Journal of the American Chemical Society · doi:10.1021/ja9542193 · Cited by 894
Accelerated Reaction Kinetics in Microdroplets: Overview and Recent Developments
Wei, Z., Li, Y., Cooks, R. G., & Yan, X. (2020) · Annual Review of Physical Chemistry · doi:10.1146/annurev-physchem-121319-110654 · Cited by 631
Metadata
- Authors
- Dole, M., Mack, L. L., Hines, R. L., Mobley, R. C., Ferguson, L. D., & Alice, M. B.
- Venue
- The Journal of Chemical Physics
- Publisher
- AIP Publishing
- Published
- 1968-09-01
- Volume
- 49
- Issue
- 5
- Pages
- 2240-2249
- ISSN
- 0021-9606 (ISSN-L)
- 1089-7690
- OpenAlex
- W1974732006
- Cited by
- 1,613
- References
- 0
- FWCI
- 2.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Molecular Beams of Macroions. https://app.cochat.ai/papers/10.1063/1.1670391
- The paper
- Dole, M., Mack, L. L., Hines, R. L., Mobley, R. C., Ferguson, L. D., & Alice, M. B. (1968). Molecular Beams of Macroions. The Journal of Chemical Physics. https://doi.org/10.1063/1.1670391
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.