The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Fluorescent Probes for Hydrogen Peroxide Based on a Non‐Oxidative Mechanism
Abstract
Highly selective detection of H2O2 through a non-oxidative mechanism has been achieved by desulfonylation of 1 to the corresponding fluorescein. This approach has been used for the intracellular formation of H2O2 in algal cells by using the acetyl derivatives of 1 as fluorescent probes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Free Radicals in Biology and Medicine
Halliwell, B., & Gutteridge, J. M. C. (2015) · doi:10.1093/acprof:oso/9780198717478.001.0001 · Cited by 8,990
Wang, H., & Joseph, J. A. (1999) · Free Radical Biology and Medicine · doi:10.1016/s0891-5849(99)00107-0 · Cited by 2,346
Schutzendubel, A. (2002) · Journal of Experimental Botany · doi:10.1093/jexbot/53.372.1351 · Cited by 1,990
Bass, D. A., Parce, J. W., Dechatelet, L. R., Szejda, P., Seeds, M. C., & Thomas, M. (1983) · The Journal of Immunology · doi:10.4049/jimmunol.130.4.1910 · Cited by 1,809
Zhou, M., Diwu, Z., Panchuk-Voloshina, N., & Haugland, R. P. (1997) · Analytical Biochemistry · doi:10.1006/abio.1997.2391 · Cited by 1,396
Royall, J. A., & Ischiropoulos, H. (1993) · Archives of Biochemistry and Biophysics · doi:10.1006/abbi.1993.1222 · Cited by 1,119
Hempel, S. L., Buettner, G. R., O’Malley, Y. Q., Wessels, D. A., & Flaherty, D. M. (1999) · Free Radical Biology and Medicine · doi:10.1016/s0891-5849(99)00061-1 · Cited by 740
The fluorometric analysis of ultramicro quantities of hydrogen peroxide
Keston, A. S., & Brandt, R. (1965) · Analytical Biochemistry · doi:10.1016/0003-2697(65)90034-5 · Cited by 597
New nitric oxide-releasing zwitterions derived from polyamines
Hrabie, J. A., Klose, J. R., Wink, D. A., & Keefer, L. K. (1993) · The Journal of Organic Chemistry · doi:10.1021/jo00058a030 · Cited by 592
Fluorescent Indicators for Imaging Nitric Oxide Production
Kojima, H., Urano, Y., Kikuchi, K., Higuchi, T., Hirata, Y., & Nagano, T. (1999) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(19991102)38:21<3209::aid-anie3209>3.0.co;2-6 · Cited by 570
Cited by
Luminescent Chemodosimeters for Bioimaging
Yang, Y., Zhao, Q., Feng, W., & Li, F. (2013) · Chemical Reviews · doi:10.1021/cr2004103 · Cited by 2,236
Design Strategies for Water-Soluble Small Molecular Chromogenic and Fluorogenic Probes
Li, X., Gao, X., Shi, W., & Ma, H. (2014) · Chemical Reviews · doi:10.1021/cr300508p · Cited by 1,729
A tissue-scale gradient of hydrogen peroxide mediates rapid wound detection in zebrafish
Niethammer, P., Grabher, C., Look, A. T., & Mitchison, T. J. (2009) · Nature · doi:10.1038/nature08119 · Cited by 1,541
Tsukagoshi, H., Busch, W., & Benfey, P. N. (2010) · Cell · doi:10.1016/j.cell.2010.10.020 · Cited by 1,081
Fluorescent and luminescent probes for detection of reactive oxygen and nitrogen species
Chen, X., Tian, X., Shin, I., & Yoon, J. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15037e · Cited by 980
Wardman, P. (2007) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2007.06.026 · Cited by 864
The Art of Fluorescence Imaging with Chemical Sensors
Schäferling, M. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201105459 · Cited by 721
A Selective, Cell-Permeable Optical Probe for Hydrogen Peroxide in Living Cells
Chang, M. C. Y., Pralle, A., Isacoff, E. Y., & Chang, C. J. (2004) · Journal of the American Chemical Society · doi:10.1021/ja0441716 · Cited by 651
Boronate-Based Fluorescent Probes for Imaging Cellular Hydrogen Peroxide
Miller, E. W., Albers, A. E., Pralle, A., Isacoff, E. Y., & Chang, C. J. (2005) · Journal of the American Chemical Society · doi:10.1021/ja054474f · Cited by 591
Srikun, D., Miller, E. W., Domaille, D. W., & Chang, C. J. (2008) · Journal of the American Chemical Society · doi:10.1021/ja711480f · Cited by 543
Dickinson, B. C., Huynh, C., & Chang, C. J. (2010) · Journal of the American Chemical Society · doi:10.1021/ja1014103 · Cited by 515
Molecular imaging of hydrogen peroxide produced for cell signaling
Miller, E. W., Tulyathan, O., Isacoff, E. Y., & Chang, C. J. (2007) · Nature Chemical Biology · doi:10.1038/nchembio871 · Cited by 450
Modern reaction-based indicator systems
Cho, D.-G., & Sessler, J. L. (2009) · Chemical Society Reviews · doi:10.1039/b804436h · Cited by 421
Winterbourn, C. C. (2014) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/j.bbagen.2013.05.004 · Cited by 417
Van de Bittner, G. C., Dubikovskaya, E. A., Bertozzi, C. R., & Chang, C. J. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1012864107 · Cited by 403
Development of a Highly Sensitive Fluorescence Probe for Hydrogen Peroxide
Abo, M., Urano, Y., Hanaoka, K., Terai, T., Komatsu, T., & Nagano, T. (2011) · Journal of the American Chemical Society · doi:10.1021/ja203521e · Cited by 394
Djurišić, A. B., Leung, Y. H., Ng, A. M. C., Xu, X. Y., Lee, P. K. H., Degger, N., & Wu, R. S. S. (2015) · Small · doi:10.1002/smll.201303947 · Cited by 393
A FRET-Based Approach to Ratiometric Fluorescence Detection of Hydrogen Peroxide
Albers, A. E., Okreglak, V. S., & Chang, C. J. (2006) · Journal of the American Chemical Society · doi:10.1021/ja063308k · Cited by 375
Oushiki, D., Kojima, H., Terai, T., Arita, M., Hanaoka, K., Urano, Y., & Nagano, T. (2010) · Journal of the American Chemical Society · doi:10.1021/ja910090v · Cited by 361
Advances in modifying fluorescein and rhodamine fluorophores as fluorescent chemosensors
Zheng, H., Zhan, X.-Q., Bian, Q.-N., & Zhang, X.-J. (2013) · Chem. Commun. · doi:10.1039/c2cc35997a · Cited by 345
Recent advances in fluorescent probes for the detection of reactive oxygen species
Soh, N. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0366-9 · Cited by 327
Hyman, L. M., & Franz, K. J. (2012) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2012.03.009 · Cited by 325
Small-molecule fluorophores and fluorescent probes for bioimaging
Terai, T., & Nagano, T. (2013) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-013-1234-z · Cited by 301
Fluorescent probes for the selective detection of chemical species inside mitochondria
Xu, Z., & Xu, L. (2016) · Chemical Communications · doi:10.1039/c5cc09248e · Cited by 291
Activity‐Based Sensing: A Synthetic Methods Approach for Selective Molecular Imaging and Beyond
Bruemmer, K. J., Crossley, S. W. M., & Chang, C. J. (2020) · Angewandte Chemie International Edition · doi:10.1002/anie.201909690 · Cited by 265
A design of fluorescent probes for superoxide based on a nonredox mechanism
Maeda, H., Yamamoto, K., Nomura, Y., Kohno, I., Hafsi, L., Ueda, N., Yoshida, S., Fukuda, M., Fukuyasu, Y., Yamauchi, Y., et al. (2005) · Journal of the American Chemical Society · doi:10.1021/ja047018k · Cited by 196
Self-citationMaeda, H., Yamamoto, K., Kohno, I., Hafsi, L., Itoh, N., Nakagawa, S., Kanagawa, N., Suzuki, K., & Uno, T. (2007) · Chemistry – A European Journal · doi:10.1002/chem.200600522 · Cited by 85
Self-citationA selenium-contained aggregation-induced “turn-on” fluorescent probe for hydrogen peroxide
Liao, Y.-X., Li, K., Wu, M.-Y., Wu, T., & Yu, X.-Q. (2014) · Organic & Biomolecular Chemistry · doi:10.1039/c4ob00206g · Cited by 58
Metadata
- Authors
- Maeda, H., Fukuyasu, Y., Yoshida, S., Fukuda, M., Saeki, K., Matsuno, H., Yamauchi, Y., Yoshida, K., Hirata, K., & Miyamoto, K.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2004-04-22
- Volume
- 43
- Issue
- 18
- Pages
- 2389-2391
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W2148328739
- Cited by
- 270
- References
- 27
- FWCI
- 2.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.