The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
A FRET-Based Approach to Ratiometric Fluorescence Detection of Hydrogen Peroxide
Abstract
We report the synthesis, properties, and biological applications of Ratio-Peroxyfluor-1 (RPF1), a new ratiometric fluorescent reporter for hydrogen peroxide. RPF1 is comprised of a two-fluorophore cassette, where the spectral overlap between coumarin donor and fluoran/fluorescein acceptor partners can be controlled by the chemoselective peroxide-mediated deprotection of boronic ester pendants on the acceptor dye. RPF1 features good selectivity for hydrogen peroxide over a variety of reactive oxygen species, including superoxide and nitric oxide, a ca. 8-fold increase in fluorescence intensity ratio (lambda517/lambda464) upon H2O2 reaction, and excitation and emission profiles in the visible region. Experiments with viable yeast mitochondria show that RPF1 can monitor and quantify endogenous production of H2O2, establishing the potential utility of this approach for probing peroxide biology in living systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Free Radicals in Biology and Medicine
Halliwell, B., & Gutteridge, J. M. C. (2015) · doi:10.1093/acprof:oso/9780198717478.001.0001 · Cited by 8,990
Mitochondria, Oxidants, and Aging
Balaban, R. S., Nemoto, S., & Finkel, T. (2005) · Cell · doi:10.1016/j.cell.2005.02.001 · Cited by 4,388
Neurodegenerative diseases and oxidative stress
Barnham, K. J., Masters, C. L., & Bush, A. I. (2004) · Nature Reviews Drug Discovery · doi:10.1038/nrd1330 · Cited by 3,683
Hempel, S. L., Buettner, G. R., O’Malley, Y. Q., Wessels, D. A., & Flaherty, D. M. (1999) · Free Radical Biology and Medicine · doi:10.1016/s0891-5849(99)00061-1 · Cited by 740
Chemical basis of inflammation-induced carcinogenesis
Ohshima, H., Tatemichi, M., & Sawa, T. (2003) · Archives of Biochemistry and Biophysics · doi:10.1016/s0003-9861(03)00283-2 · Cited by 620
Boronate-Based Fluorescent Probes for Imaging Cellular Hydrogen Peroxide
Miller, E. W., Albers, A. E., Pralle, A., Isacoff, E. Y., & Chang, C. J. (2005) · Journal of the American Chemical Society · doi:10.1021/ja054474f · Cited by 591
Self-citationFluorescence ratio imaging: a new window into intracellular ionic signaling
Tsien, R. Y., & Poenie, M. (1986) · Trends in Biochemical Sciences · doi:10.1016/0968-0004(86)90245-8 · Cited by 414
A Europium-Ion-Based Luminescent Sensing Probe for Hydrogen Peroxide
Wolfbeis, O. S., Dürkop, A., Wu, M., & Lin, Z. (2002) · Angewandte Chemie International Edition · doi:10.1002/1521-3773(20021202)41:23<4495::aid-anie4495>3.0.co;2-i · Cited by 297
Fluorescent Probes for Hydrogen Peroxide Based on a Non‐Oxidative Mechanism
Maeda, H., Fukuyasu, Y., Yoshida, S., Fukuda, M., Saeki, K., Matsuno, H., Yamauchi, Y., Yoshida, K., Hirata, K., & Miyamoto, K. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200452381 · Cited by 270
Free radicals and redox signalling in cardiovascular disease
Shah, A. M., & Channon, K. M. (2004) · Heart · doi:10.1136/hrt.2003.029389 · Cited by 194
Cited by
Fluorescent and luminescent probes for detection of reactive oxygen and nitrogen species
Chen, X., Tian, X., Shin, I., & Yoon, J. (2011) · Chemical Society Reviews · doi:10.1039/c1cs15037e · Cited by 980
Zhan, W.-W., Kuang, Q., Zhou, J.-Z., Kong, X.-J., Xie, Z.-X., & Zheng, L.-S. (2013) · Journal of the American Chemical Society · doi:10.1021/ja311085e · Cited by 803
Qian, Z., Ma, J., Shan, X., Feng, H., Shao, L., & Chen, J. (2014) · Chemistry – A European Journal · doi:10.1002/chem.201304374 · Cited by 486
ROS production in phagocytes: Why, when, and where?
Dupré-Crochet, S., Erard, M., & Nüβe, O. (2013) · Journal of Leukocyte Biology · doi:10.1189/jlb.1012544 · Cited by 467
Redox Signaling by Reactive Electrophiles and Oxidants
Parvez, S., Long, M. J. C., Poganik, J. R., & Aye, Y. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00698 · Cited by 359
Metadata
- Authors
- Albers, A. E., Okreglak, V. S., & Chang, C. J.
- Venue
- Journal of the American Chemical Society
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-07-04
- Volume
- 128
- Issue
- 30
- Pages
- 9640-9641
- ISSN
- 0002-7863 (ISSN-L)
- 1520-5126
- OpenAlex
- W2049061652
- Cited by
- 375
- References
- 13
- FWCI
- 5.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A FRET-Based Approach to Ratiometric Fluorescence Detection of Hydrogen Peroxide. https://app.cochat.ai/papers/10.1021/ja063308k
- The paper
- Albers, A. E., Okreglak, V. S., & Chang, C. J. (2006). A FRET-Based Approach to Ratiometric Fluorescence Detection of Hydrogen Peroxide. Journal of the American Chemical Society. https://doi.org/10.1021/ja063308k
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.