The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Neutral Desorption Sampling of Living Objects for Rapid Analysis by Extractive Electrospray Ionization Mass Spectrometry
Abstract
MS comes to life: A novel method to sample surfaces of biological objects uses a neutral gas beam for in vivo EESI mass spectrometric analysis without sample pretreatment (see picture; QTOF=quadropole time-of-flight). The sampling process results in rapid in vivo analyses with reduced ion suppression and without chemical contamination. This strategy can be used in food quality monitoring, homeland security, metabolomics, and clinical diagnosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biogenic amines and their production by microorganisms in food
Halász, A., Baráth, Á., Simon-Sarkadi, L., & Holzapfel, W. (1994) · Trends in Food Science & Technology · doi:10.1016/0924-2244(94)90070-1 · Cited by 1,019
Cited by
Low-Temperature Plasma Probe for Ambient Desorption Ionization
Harper, J. D., Charipar, N. A., Mulligan, C. C., Zhang, X., Cooks, R. G., & Ouyang, Z. (2008) · Analytical Chemistry · doi:10.1021/ac801641a · Cited by 730
Ambient desorption ionization mass spectrometry
Venter, A., Nefliu, M., & Graham Cooks, R. (2008) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2008.01.010 · Cited by 552
Mass Spectrometry: Recent Advances in Direct Open Air Surface Sampling/Ionization
Monge, M. E., Harris, G. A., Dwivedi, P., & Fernández, F. M. (2013) · Chemical Reviews · doi:10.1021/cr300309q · Cited by 476
Weston, D. J. (2010) · The Analyst · doi:10.1039/b925579f · Cited by 357
Ambient mass spectrometry: bringing MS into the “real world”
Alberici, R. M., Simas, R. C., Sanvido, G. B., Romão, W., Lalli, P. M., Benassi, M., Cunha, I. B. S., & Eberlin, M. N. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3808-3 · Cited by 340
Metadata
- Authors
- Chen, H., Yang, S., Wortmann, A., & Zenobi, R.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2007-09-28
- Volume
- 46
- Issue
- 40
- Pages
- 7591-7594
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W2108658563
- Cited by
- 169
- References
- 1
- FWCI
- 7.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Neutral Desorption Sampling of Living Objects for Rapid Analysis by Extractive Electrospray Ionization Mass Spectrometry. https://app.cochat.ai/papers/10.1002/anie.200702200
- The paper
- Chen, H., Yang, S., Wortmann, A., & Zenobi, R. (2007). Neutral Desorption Sampling of Living Objects for Rapid Analysis by Extractive Electrospray Ionization Mass Spectrometry. Angewandte Chemie International Edition. https://doi.org/10.1002/anie.200702200
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.