Dual Acquisition Magic‐Angle Spinning Solid‐State NMR‐Spectroscopy: Simultaneous Acquisition of Multidimensional Spectra of Biomacromolecules
Open accessThe DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index; none of the 33 sources its claims cite is checked for support yet.
Abstract
Fast data collection: a general method for dual data acquisition of multidimensional magic-angle spinning solid-state NMR experiments is presented. The method uses a simultaneous Hartmann-Hahn cross-polarization from (1)H to (13)C and (15)N nuclei and exploits the long-living (15)N polarization for parallel acquisition of two multidimensional experiments.
Overview
CoChat Summary
TL;DR
The paper introduces DUMAS ssNMR, a pulse-sequence approach that uses simultaneous 1H-13C/15N cross-polarization and storage of long-lived 15N z-magnetization to acquire 13C- and 15N-edited multidimensional MAS ssNMR spectra in parallel without extra hardware. It demonstrates roughly halved acquisition times for DARR/NCA and DQSQ/NCO pairs on microcrystalline ubiquitin, with modest sensitivity losses for the 15N-edited experiments, and extends the approach to phospholamban in lipid membranes.
Key findings
- DUMAS-DARR-NCA acquired DARR and NCA simultaneously in 8.12 h versus 16.03 h for conventional separate acquisition; DUMAS-DQSQ-NCO acquired DQSQ and NCO simultaneously in 8.06 h versus 15.57 h conventional. DUMAS-DARR sensitivity was identical to conventional DARR, DUMAS-NCA was about 80% of conventional NCA, DUMAS-DQSQ was similar to conventional DQSQ, and DUMAS-NCO showed approximately 20% sensitivity loss.
- In SIM-CP comparisons, 13C sensitivity between 0 and 80 ppm was nearly identical to conventional CP at all contact times, while the 13C carbonyl region was 5–15% higher for CP; 15N sensitivity loss for SIM-CP was ~12–23%. Optimal contact times were 400 µs (1H-13C), 600 µs (1H-15N), and 400 µs (SIM-CP) for ubiquitin, and 300 µs, 500 µs, and 300 µs respectively for phospholamban.
- 15N magnetization stored along the z-axis showed negligible decay during the first 13C-edited acquisition. DUMAS was applied to U-13C,15N phospholamban in lipid membranes: conventional DARR and NCA each took ~16 h, while DUMAS acquired them simultaneously in ~16 h.
- The authors state DUMAS is a general approach that can concatenate various multidimensional ssNMR experiments and can be combined with perdeuteration, paramagnetic relaxation enhancement, DNP, proton detection, and multiple receivers, though these combinations are anticipated rather than demonstrated here.
Methods
- All NMR experiments used a 700 MHz VNMRS spectrometer (Agilent Technologies) equipped with a 3.2 mm bioMAS scroll coil probe, at a spinning rate of 8.333 kHz and 5 °C.
- Samples were U-13C,15N microcrystalline ubiquitin (10 mg dissolved in 20 mM citrate buffer, pH 4.1, to 35 mg/mL, crystallized with 60% 2-methyl-2,4-pentanediol, ~5 mg loaded into the rotor) and U-13C,15N phospholamban (52 residues) expressed in E. coli and reconstituted in lipid membranes.
- DUMAS-DARR-NCA and DUMAS-DQSQ-NCO pulse sequences were tested. SIM-CP used 1H/13C/15N RF field strengths of 45/36.7/36.7 kHz (n=1 sideband matching) with 1H RF amplitude ramped by 10%; comparisons used conventional CP and integrated peak intensities as a function of contact time.
Limitations
- Stated: SIM-CP causes sensitivity losses, including ~12–23% for 15N spectra and ~20% for DUMAS-NCA and DUMAS-NCO, and the 13C carbonyl region is 5–15% higher for conventional CP. The authors also note it is difficult to derive a theoretical quantitative expression for SIM-CP.
- Stated/evident: demonstrations are limited to microcrystalline ubiquitin and phospholamban in lipid membranes; combinations with DNP, PRE, proton detection, and multiple receivers are anticipated but not experimentally shown in this paper.
- Evident: DUMAS relies on long 15N T1 and negligible z-magnetization decay during the first acquisition, so performance may depend on sample-specific relaxation behavior.
Model-written summary. Check it against the paper before relying on it.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
0 Valid · 0 Not valid · 16 Not checked · 34 Own results and interpretations
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Notably, the sensitivity in the 13C spectral region between 0 and 80 ppm is nearly identical for both CP and SIM-CP at all contact times.”
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“while the DUMAS-DQSQ spectrum is similar to the conventional DQSQ.”
plainSingle case- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“We also demonstrate that DUMAS pulse sequences can be applied to more challenging systems such as integral membrane protein phospholamban reconstituted in lipid membrane.”
boostedSingle case- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
- Rests on an assumption not shown here.
A result the paper states — it cites no source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“As for the NCA, the sensitivity loss for the DUMAS-NCO is approximately 20%”
plain- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: unclear — It is unclear whether the paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
A result the paper reports from its own data — it cites no other source for it, so there is none to check. The quote shows it is in the paper.
In the paper
“Figure 3A shows the two spectra acquired with the conventional methods for a total acquisition time of 15.57 hours.”
plainSingle case- Asserted: passes — The authors put it forward as true.
- Checkable: passes — It can be checked against evidence.
- Load-bearing: passes — The paper’s conclusions depend on it.
- Based: passes — The paper gives a reason why it holds.
26 more claims
Create a free account to see all 50 claims and to verify the 30 references still open.
- It may state two separate claims as one. 7
- Probably not a substantial claim. 13
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Using different strategies (i.e., DUMAS, MEIOSIS, and MAeSTOSO), we implemented the simultaneous acquisition of multiple 2D and 3D spectra at slow and fast spinning rates using either 1H- or 13C- detected single-receiver experiments22,24–27.”
From Multi-receiver solid-state NMR using polarization optimized experiments (POE) at ultrafast magic angle spinning (2020) · cites this paper as [24]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Recently, we introduced two new strategies, namely DUMAS (DUal acquisition Magic Angle Spinning) and MEIOSIS (Multiple ExperIments via Orphan SpIn operatorS), that enable the simultaneous acquisitions of multidimensional ssNMR experiments using multiple coherence transfer pathways.”
From Multiple acquisitions via sequential transfer of orphan spin polarization (MAeSTOSO): How far can we push residual spin polarization in solid-state NMR? (2016) · cites this paper as [11]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“In the case of 2D DUMAS, we were able to combine CC and NC correlation experiments.”
From Multiple acquisitions via sequential transfer of orphan spin polarization (MAeSTOSO): How far can we push residual spin polarization in solid-state NMR? (2016) · cites this paper as [11]
The cited source says what the claim attributes to it.
In the citing paper
“The first example is DUMAS method that doubles the capability of ssNMR spectrometers via two acquisition periods without repeating the recycle delay.”
From Orphan Spin Polarization (2016) · cites this paper as [22]
In the citing paper
“PHRONESIS is a blank canvas for designing novel multidimensional ssNMR experiments by concatenating different multi‐dimensional pulse sequences, speeding up the spectral assignment, and structure determination of complex macromolecules.[ 19 , 20 , 21 , 22 , 23 , 24 , 25 , 26 , 27 , 28 , 29 , 30 , 31 , 32 ]”
From PHRONESIS: A One‐Shot Approach for Sequential Assignment of Protein Resonances by Ultrafast MAS Solid‐State NMR Spectroscopy (2022) · cites this paper as [19]
14 more claims about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Proton-enhanced NMR of dilute spins in solids
Pines, A., Gibby, M. G., & Waugh, J. S. (1973) · The Journal of Chemical Physics · doi:10.1063/1.1680061 · Cited by 2,493
Kay, L., Keifer, P., & Saarinen, T. (1992) · Journal of the American Chemical Society · doi:10.1021/ja00052a088 · Cited by 2,247
Nuclear Double Resonance in the Rotating Frame
Hartmann, S. R., & Hahn, E. L. (1962) · Physical Review · doi:10.1103/physrev.128.2042 · Cited by 2,236
Heteronuclear decoupling in rotating solids
Bennett, A. E., Rienstra, C. M., Auger, M., Lakshmi, K. V., & Griffin, R. G. (1995) · The Journal of Chemical Physics · doi:10.1063/1.470372 · Cited by 2,124
– dipolar-assisted rotational resonance in magic-angle spinning NMR
Takegoshi, K., Nakamura, S., & Terao, T. (2001) · Chemical Physics Letters · doi:10.1016/s0009-2614(01)00791-6 · Cited by 1,012
Dynamic nuclear polarization at high magnetic fields
Maly, T., Debelouchina, G. T., Bajaj, V. S., Hu, K.-N., Joo, C.-G., Mak–Jurkauskas, M. L., Sirigiri, J. R., van der Wel, P. C. A., Herzfeld, J., Temkin, R. J., et al. (2008) · The Journal of Chemical Physics · doi:10.1063/1.2833582 · Cited by 919
BALDUS, M., PETKOVA, A. T., HERZFELD, J., & GRIFFIN, R. G. (1998) · Molecular Physics · doi:10.1080/00268979809483251 · Cited by 588
Solid-State NMR Studies of Amyloid Fibril Structure
Tycko, R. (2011) · Annual Review of Physical Chemistry · doi:10.1146/annurev-physchem-032210-103539 · Cited by 545
Hohwy, M., Rienstra, C. M., Jaroniec, C. P., & Griffin, R. G. (1999) · The Journal of Chemical Physics · doi:10.1063/1.478702 · Cited by 391
Dipolar recoupling in MAS spectra of biological solids
Griffin, R. (1998) · Nature Structural Biology · doi:10.1038/749 · Cited by 345
Research works printed but not linked: 3
- 10.1002/cbic.201000124 · DOI · Paper page
- Gopinath T Mote K Veglia G 2011 (Under Review).
- Akbey U Camponeschi F van Rossum BJ Oschkinat H Chemphyschem 2011 21656893
Cited by
Influences of Membrane Mimetic Environments on Membrane Protein Structures
Zhou, H.-X., & Cross, T. A. (2013) · Annual Review of Biophysics · doi:10.1146/annurev-biophys-083012-130326 · Cited by 267
Nishiyama, Y., Hou, G., Agarwal, V., Su, Y., & Ramamoorthy, A. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00197 · Cited by 170
Paudel, A., Geppi, M., & den Mooter, G. V. (2014) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.23966 · Cited by 147
Understanding Surface and Interfacial Chemistry in Functional Nanomaterials via Solid‐State NMR
Marchetti, A., Chen, J., Pang, Z., Li, S., Ling, D., Deng, F., & Kong, X. (2017) · Advanced Materials · doi:10.1002/adma.201605895 · Cited by 132
Solid-State NMR: Methods for Biological Solids
Ahlawat, S., Mote, K. R., Lakomek, N., & Agarwal, V. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00852 · Cited by 119
Metadata
- Authors
- Gopinath, T., & Veglia, G.
- Affiliations
- University of Minnesota (US)
- Corresponding author
- Veglia, Gianluigi
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2012-02-06
- Volume
- 51
- Issue
- 11
- Pages
- 2731-2735
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- PMC
- PMC3513283
- OpenAlex
- W2007407544
- Semantic Scholar
- d87b207c09146d663932d875033a0de1d37524e9
- Cited by
- 84
- References
- 58
- Citations by year
- 2025: 1 · 2024: 4 · 2023: 3 · 2022: 6 · 2021: 9 · 2020: 7 · 2019: 7 · 2018: 3 · 2017: 7 · 2016: 7 · 2015: 7 · 2014: 6 · 2013: 13 · 2012: 4
- FWCI
- 3.38
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Angewandte Chemie International Edition (publishedVersion)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institute of General Medical Sciences (R01GM072701, R01GM064742)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Advanced NMR Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Electron Spin Resonance Studies
- Physical Sciences › Chemistry › Spectroscopy › NMR spectroscopy and applications
- Keywords
- magic angle spinning, multidimensional NMR, 1H-13C cross-polarization, parallel acquisition, biological macromolecules, solid-state NMR
- MeSH terms
- Carbon Isotopes, Hydrogen, Nitrogen Isotopes, Nuclear Magnetic Resonance, Biomolecular, Ubiquitin, Macromolecular Substances
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
A language model drew the claims from the paper on 2026-11-19, under version 3 of the claim definition (model deepseek-v4.1-flash, prompt extract-v3).
A second model labelled each claim on 2026-11-19 (model jev-1.13-20260917, definition revision gold-guideline-v0.2).
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.