The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
A Ratiometric Fluorescent Probe for Rapid Detection of Hydrogen Sulfide in Mitochondria
Abstract
Quick: An exogenously induced quick increase of the H2S concentration (80 s) in MCF-7 cells can be visualized by ratiometric imaging using a new probe (CouMC) that can target mitochondria. CouMC was constructed by combining merocyanine and coumarin fluorophores. The selective nucleophilic addition of HS− to the merocyanine derivative at neutral pH is crucial for the rapid H2S detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
Brain hydrogen sulfide is severely decreased in Alzheimer's disease
Eto, K., Asada, T., Arima, K., Makifuchi, T., & Kimura, H. (2002) · Biochemical and Biophysical Research Communications · doi:10.1016/s0006-291x(02)00422-9 · Cited by 809
RetractedH 2 S as a Physiologic Vasorelaxant: Hypertension in Mice with Deletion of Cystathionine γ-Lyase
Yang, G., Wu, L., Jiang, B., Yang, W., Qi, J., Cao, K., Meng, Q., Mustafa, A. K., Mu, W., Zhang, S., et al. (2008) · Science · doi:10.1126/science.1162667 · Cited by 2,310
The possible role of hydrogen sulfide as an endogenous neuromodulator
Abe, K., & Kimura, H. (1996) · The Journal of Neuroscience · doi:10.1523/jneurosci.16-03-01066.1996 · Cited by 2,239
Hydrogen sulphide and its therapeutic potential
Szabó, C. (2007) · Nature Reviews Drug Discovery · doi:10.1038/nrd2425 · Cited by 2,038
The vasorelaxant effect of H2S as a novel endogenous gaseous KATP channel opener
Zhao, W. (2001) · The EMBO Journal · doi:10.1093/emboj/20.21.6008 · Cited by 1,936
Spiropyrans and Spirooxazines for Memories and Switches
Berkovic, G., Krongauz, V., & Weiss, V. (2000) · Chemical Reviews · doi:10.1021/cr9800715 · Cited by 1,588
Elrod, J. W., Calvert, J. W., Morrison, J., Doeller, J. E., Kraus, D. W., Tao, L., Jiao, X., Scalia, R., Kiss, L., Szabo, C., et al. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0705891104 · Cited by 1,255
Photo-, Thermo-, Solvato-, and Electrochromic Spiroheterocyclic Compounds
Minkin, V. I. (2004) · Chemical Reviews · doi:10.1021/cr020088u · Cited by 937
Hydrogen sulfide is an endogenous stimulator of angiogenesis
Papapetropoulos, A., Pyriochou, A., Altaany, Z., Yang, G., Marazioti, A., Zhou, Z., Jeschke, M. G., Branski, L. K., Herndon, D. N., Wang, R., et al. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0908047106 · Cited by 862
Hydrogen sulfide is an endogenous modulator of leukocyte‐mediated inflammation
Zanardo, R. C. O., Brancaleone, V., Distrutti, E., Fiorucci, S., Cirino, G., Wallace, J. L., Zanardo, R. C. O., Brancaleone, V., Distrutti, E., Fiorucci, S., et al. (2006) · The FASEB Journal · doi:10.1096/fj.06-6270fje · Cited by 859
Culotta, E., & Koshland, D. E. (1992) · Science · doi:10.1126/science.1361684 · Cited by 786
Hydrogen sulfide is a novel mediator of lipopolysaccharide‐induced inflammation in the mouse
Li, L., Bhatia, M., Zhu, Y. Z., Zhu, Y. C., Ramnath, R. D., Wang, Z. J., Anuar, F. B. M., Whiteman, M., Salto‐Tellez, M., & Moore, P. K. (2005) · The FASEB Journal · doi:10.1096/fj.04-3583fje · Cited by 773
Reaction-Based Fluorescent Probes for Selective Imaging of Hydrogen Sulfide in Living Cells
Lippert, A. R., New, E. J., & Chang, C. J. (2011) · Journal of the American Chemical Society · doi:10.1021/ja203661j · Cited by 760
Hydrogen Sulfide Mediates Cardioprotection Through Nrf2 Signaling
Calvert, J. W., Jha, S., Gundewar, S., Elrod, J. W., Ramachandran, A., Pattillo, C. B., Kevil, C. G., & Lefer, D. J. (2009) · Circulation Research · doi:10.1161/circresaha.109.199919 · Cited by 723
Smooth muscle cell-derived carbon monoxide is a regulator of vascular cGMP.
Morita, T., Perrella, M. A., Lee, M. E., & Kourembanas, S. (1995) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.92.5.1475 · Cited by 707
Development of a Highly Selective Fluorescence Probe for Hydrogen Sulfide
Sasakura, K., Hanaoka, K., Shibuya, N., Mikami, Y., Kimura, Y., Komatsu, T., Ueno, T., Terai, T., Kimura, H., & Nagano, T. (2011) · Journal of the American Chemical Society · doi:10.1021/ja207851s · Cited by 661
A Fluorescent Probe for Fast and Quantitative Detection of Hydrogen Sulfide in Blood
Peng, H., Cheng, Y., Dai, C., King, A. L., Predmore, B. L., Lefer, D. J., & Wang, B. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201104236 · Cited by 637
Furne, J., Saeed, A., & Levitt, M. D. (2008) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.90566.2008 · Cited by 633
Endogenous hydrogen sulfide overproduction in Down syndrome
Kamoun, P., Belardinelli, M., Chabli, A., Lallouchi, K., & Chadefaux‐Vekemans, B. (2003) · American Journal of Medical Genetics Part A · doi:10.1002/ajmg.a.10847 · Cited by 612
Capture and Visualization of Hydrogen Sulfide by a Fluorescent Probe
Liu, C., Pan, J., Li, S., Zhao, Y., Wu, L. Y., Berkman, C. E., Whorton, A. R., & Xian, M. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201104305 · Cited by 578
Selective fluorescent probes for live-cell monitoring of sulphide
Qian, Y., Karpus, J., Kabil, O., Zhang, S.-Y., Zhu, H.-L., Banerjee, R., Zhao, J., & He, C. (2011) · Nature Communications · doi:10.1038/ncomms1506 · Cited by 506
Selective turn-on fluorescent probes for imaging hydrogen sulfide in living cells
Montoya, L. A., & Pluth, M. D. (2012) · Chemical Communications · doi:10.1039/c2cc30730h · Cited by 422
Yu, F., Li, P., Song, P., Wang, B., Zhao, J., & Han, K. (2012) · Chemical Communications · doi:10.1039/c2cc17658k · Cited by 372
A New Chromo-chemodosimeter Selective for Sulfide Anion
Jiménez, D., Martínez-Máñez, R., Sancenón, F., Ros-Lis, J. V., Benito, A., & Soto, J. (2003) · Journal of the American Chemical Society · doi:10.1021/ja0347336 · Cited by 355
Systematic Modulation of Michael-Type Reactivity of Thiols through the Use of Charged Amino Acids
Lutolf, M. P., Tirelli, N., Cerritelli, S., Cavalli, L., & Hubbell, J. A. (2001) · Bioconjugate Chemistry · doi:10.1021/bc015519e · Cited by 355
A new gaseous signaling molecule emerges: Cardioprotective role of hydrogen sulfide
Lefer, D. J. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0709010104 · Cited by 347
Reaction-Based Genetically Encoded Fluorescent Hydrogen Sulfide Sensors
Chen, S., Chen, Z.-J., Ren, W., & Ai, H.-W. (2012) · Journal of the American Chemical Society · doi:10.1021/ja303261d · Cited by 318
Fluorescent Probes for the Detection of Hydrogen Sulfide in Biological Systems
Xuan, W., Sheng, C., Cao, Y., He, W., & Wang, W. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201107025 · Cited by 294
Self-citationHou, F., Huang, L., Xi, P., Cheng, J., Zhao, X., Xie, G., Shi, Y., Cheng, F., Yao, X., Bai, D., et al. (2012) · Inorganic Chemistry · doi:10.1021/ic2024082 · Cited by 278
Savage, J. C., & Gould, D. H. (1990) · Journal of Chromatography B: Biomedical Sciences and Applications · doi:10.1016/s0378-4347(00)82537-2 · Cited by 198
Qian, Y., Zhang, L., Ding, S., Deng, X., He, C., Zheng, X. E., Zhu, H.-L., & Zhao, J. (2012) · Chemical Science · doi:10.1039/c2sc20537h · Cited by 189
Mixed Mode Thiol−Acrylate Photopolymerizations for the Synthesis of PEG−Peptide Hydrogels
Salinas, C. N., & Anseth, K. S. (2008) · Macromolecules · doi:10.1021/ma800621h · Cited by 172
Applications of ratio fluorescence microscopy in the study of cell physiology
Dunn, K. W., Mayor, S., Myers, J. N., & Maxfield, F. R. (1994) · The FASEB Journal · doi:10.1096/fasebj.8.9.8005385 · Cited by 107
Capture and Visualization of Hydrogen Sulfide by a Fluorescent Probe
Liu, C., Pan, J. H., Li, S., Zhao, Y., Wu, L. Y., Berkman, C. E., Whorton, A. R., & Xian, M. (2011) · Angewandte Chemie · doi:10.1002/ange.201104305 · Cited by 105
Cited by
Recent progress in the development of near-infrared fluorescent probes for bioimaging applications
Guo, Z., Park, S., Yoon, J., & Shin, I. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60271k · Cited by 1,801
Self-citationZielonka, J., Joseph, J., Sikora, A., Hardy, M., Ouari, O., Vasquez-Vivar, J., Cheng, G., Lopez, M., & Kalyanaraman, B. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00042 · Cited by 1,683
Small molecule-based ratiometric fluorescence probes for cations, anions, and biomolecules
Lee, M. H., Kim, J. S., & Sessler, J. L. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00280f · Cited by 1,642
Coumarin-Based Small-Molecule Fluorescent Chemosensors
Cao, D., Liu, Z., Verwilst, P., Koo, S., Jangjili, P., Kim, J. S., & Lin, W. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00145 · Cited by 1,306
Recent Development of Chemosensors Based on Cyanine Platforms
Sun, W., Guo, S., Hu, C., Fan, J., & Peng, X. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00001 · Cited by 1,109
Metadata
- Authors
- Chen, Y., Zhu, C., Yang, Z., Chen, J., He, Y., Jiao, Y., He, W., Qiu, L., Cen, J., & Guo, Z.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2013-01-03
- Volume
- 52
- Issue
- 6
- Pages
- 1688-1691
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W1987530130
- Cited by
- 563
- References
- 34
- FWCI
- 27.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.