In Vivo Imaging of Mouse Tumors by a Lipidated Cathepsin S Substrate
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The synthesis and evaluation of two cathepsin S‐specific probes is described. For long‐term retention of the probe at the target site and a high signal‐to‐noise ratio, we introduced a lipidation approach via the simple attachment of palmitoic acid to the reporter. After cathepsin S‐specific cleavage in cultured cells and in a grafted tumor mouse model, fluorescence increased owing to dequenching and we observed an intracellular accumulation of the fluorescence in the target tissue. The lipidated probe provided a prolonged and strongly fluorescent signal in tumors when compared to the very similar non‐lipidated probe, demonstrating that non‐invasive tumor identification is feasable. The homing principle by probe lipidation might also work for selective administration of cytotoxic compounds to specifically reduce tumor mass.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Edgington, L. E., Verdoes, M., & Bogyo, M. (2011) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2011.10.012 · Cited by 169
Cited by
Recent progresses in small-molecule enzymatic fluorescent probes for cancer imaging
Liu, H.-W., Chen, L., Xu, C., Li, Z., Zhang, H., Zhang, X.-B., & Tan, W. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00862g · Cited by 948
Cysteine Cathepsins and Their Extracellular Roles: Shaping the Microenvironment
Vidak, E., Javoršek, U., Vizovišek, M., & Turk, B. (2019) · Cells · doi:10.3390/cells8030264 · Cited by 398
Self-citationNear-infrared (NIR) fluorescence-emitting small organic molecules for cancer imaging and therapy
Li, H., Kim, Y., Jung, H., Hyun, J. Y., & Shin, I. (2022) · Chemical Society Reviews · doi:10.1039/d2cs00722c · Cited by 356
Garland, M., Yim, J. J., & Bogyo, M. (2016) · Cell Chemical Biology · doi:10.1016/j.chembiol.2015.12.003 · Cited by 254
Cathepsin S: therapeutic, diagnostic, and prognostic potential
Wilkinson, R. D. A., Williams, R., Scott, C. J., & Burden, R. E. (2015) · Biological Chemistry · doi:10.1515/hsz-2015-0114 · Cited by 215
“Furthermore , signal was rapidly produced within 30 min, which increased steadily over the following 6 h before diminishing 24 h post-injection (Hu et al., 2014).”
Metadata
- Authors
- Hu, H., Vats, D., Vizovisek, M., Kramer, L., Germanier, C., Wendt, K. U., Rudin, M., Turk, B., Plettenburg, O., & Schultz, C.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2014-05-30
- Volume
- 53
- Issue
- 29
- Pages
- 7669-7673
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W2105689679
- Cited by
- 63
- References
- 1
- FWCI
- 2.53
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In Vivo Imaging of Mouse Tumors by a Lipidated Cathepsin S Substrate. https://app.cochat.ai/papers/10.1002/anie.201310979
- The paper
- Hu, H., Vats, D., Vizovisek, M., Kramer, L., Germanier, C., Wendt, K. U., Rudin, M., Turk, B., Plettenburg, O., & Schultz, C. (2014). In Vivo Imaging of Mouse Tumors by a Lipidated Cathepsin S Substrate. Angewandte Chemie International Edition. https://doi.org/10.1002/anie.201310979
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.