The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Single‐Molecule Spectroscopy, Imaging, and Photocontrol: Foundations for Super‐Resolution Microscopy (Nobel Lecture)
Abstract
The initial steps toward optical detection and spectroscopy of single molecules in condensed matter arose out of the study of inhomogeneously broadened optical absorption profiles of molecular impurities in solids at low temperatures. Spectral signatures relating to the fluctuations of the number of molecules in resonance led to the attainment of the single‐molecule limit in 1989 using frequency‐modulation laser spectroscopy. In the early 90s, many fascinating physical effects were observed for individual molecules, and the imaging of single molecules as well as observations of spectral diffusion, optical switching and the ability to select different single molecules in the same focal volume simply by tuning the pumping laser frequency provided important forerunners of the later super‐resolution microscopy with single molecules. In the room temperature regime, imaging of single copies of the green fluorescent protein also uncovered surprises, especially the blinking and photoinduced recovery of emitters, which stimulated further development of photoswitchable fluorescent protein labels. Because each single fluorophore acts a light source roughly 1 nm in size, microscopic observation and localization of individual fluorophores is a key ingredient to imaging beyond the optical diffraction limit. Combining this with active control of the number of emitting molecules in the pumped volume led to the super‐resolution imaging of Eric Betzig and others, a new frontier for optical microscopy beyond the diffraction limit. The background leading up to these observations is described and current developments are summarized.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Precise Nanometer Localization Analysis for Individual Fluorescent Probes
Thompson, R. E., Larson, D. R., & Webb, W. W. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75618-x · Cited by 2,320
Experiments with an isolated subatomic particle at rest
Dehmelt, H. (1990) · Reviews of Modern Physics · doi:10.1103/revmodphys.62.525 · Cited by 302
Cited by
High-Resolution Native Mass Spectrometry
Tamara, S., den Boer, M. A., & Heck, A. J. R. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00212 · Cited by 511
Novikov, D. S., Kiselev, V. G., & Jespersen, S. N. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27101 · Cited by 366
Hsiao, W. W.-W., Hui, Y. Y., Tsai, P.-C., & Chang, H.-C. (2016) · Accounts of Chemical Research · doi:10.1021/acs.accounts.5b00484 · Cited by 365
BODIPY Dye, the Most Versatile Fluorophore Ever?
Bañuelos, J. (2016) · The Chemical Record · doi:10.1002/tcr.201500238 · Cited by 324
Switchable Fluorophores for Single-Molecule Localization Microscopy
Li, H., & Vaughan, J. C. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00767 · Cited by 319
Metadata
- Authors
- Moerner, W. E. (. E. ).
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2015-06-18
- Volume
- 54
- Issue
- 28
- Pages
- 8067-8093
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W1525068335
- Cited by
- 237
- References
- 2
- FWCI
- 16.57
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Single‐Molecule Spectroscopy, Imaging, and Photocontrol: Foundations for Super‐Resolution Microscopy (Nobel Lecture). https://app.cochat.ai/papers/10.1002/anie.201501949
- The paper
- Moerner, W. E. (. E. ). (2015). Single‐Molecule Spectroscopy, Imaging, and Photocontrol: Foundations for Super‐Resolution Microscopy (Nobel Lecture). Angewandte Chemie International Edition. https://doi.org/10.1002/anie.201501949
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.