The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Rapid, Quantitative, and Ultrasensitive Point‐of‐Care Testing: A Portable SERS Reader for Lateral Flow Assays in Clinical Chemistry
Open accessAbstract
The design of a portable Raman/SERS‐LFA reader with line illumination using a custom‐made fiber optic probe for rapid, quantitative, and ultrasensitive point‐of‐care testing (POCT) is presented. The pregnancy hormone human chorionic gonadotropin (hCG) is detectable in clinical samples within only 2–5 s down to approximately 1.6 mIU mL−1. This acquisition time is several orders of magnitude shorter than those of existing approaches requiring expensive Raman instrumentation, and the method is 15‐times more sensitive than a commercially available lateral flow assay (LFA) as the gold standard. The SERS‐LFA technology paves the way for affordable, quantitative, and ultrasensitive POCT with multiplexing potential in real‐world applications, ranging from clinical chemistry to food and environmental analysis as well as drug and biowarfare agent testing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Schütz, M., & Schlücker, S. (2016) · Journal of Raman Spectroscopy · doi:10.1002/jrs.4913 · Cited by 24
Self-citation
Cited by
Ultrasensitive and Highly Specific Lateral Flow Assays for Point-of-Care Diagnosis
Liu, Y., Zhan, L., Qin, Z., Sackrison, J., & Bischof, J. C. (2021) · ACS Nano · doi:10.1021/acsnano.0c10035 · Cited by 626
Flexible Plasmonic Biosensors for Healthcare Monitoring: Progress and Prospects
Song, L., Chen, J., Xu, B. B., & Huang, Y. (2021) · ACS Nano · doi:10.1021/acsnano.1c07176 · Cited by 186
The application of nanoparticles in point-of-care testing (POCT) immunoassays
Hou, F., Sun, S., Abdullah, S. W., Tang, Y., Li, X., & Guo, H. (2023) · Analytical Methods · doi:10.1039/d3ay00182b · Cited by 61
Metadata
- Authors
- Tran, V., Walkenfort, B., König, M., Salehi, M., & Schlücker, S.
- Venue
- Angewandte Chemie International Edition
- Publisher
- Wiley
- Published
- 2018-11-08
- Volume
- 58
- Issue
- 2
- Pages
- 442-446
- ISSN
- 1433-7851 (ISSN-L)
- 1521-3773
- OpenAlex
- W2894626104
- Cited by
- 323
- References
- 1
- FWCI
- 11.23
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rapid, Quantitative, and Ultrasensitive Point‐of‐Care Testing: A Portable SERS Reader for Lateral Flow Assays in Clinical Chemistry. https://app.cochat.ai/papers/10.1002/anie.201810917
- The paper
- Tran, V., Walkenfort, B., König, M., Salehi, M., & Schlücker, S. (2019). Rapid, Quantitative, and Ultrasensitive Point‐of‐Care Testing: A Portable SERS Reader for Lateral Flow Assays in Clinical Chemistry. Angewandte Chemie International Edition. https://doi.org/10.1002/anie.201810917
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.