Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 216

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Ultra‐High Initial Coulombic Efficiency Induced by Interface Engineering Enables Rapid, Stable Sodium Storage

Wan, Yanhua, Song, Keming, Chen, Weihua, Qin, Changdong, Zhang, Xixue, Zhang, Jiyu, Dai, Hongliu, Hu, Zhe, Yan, Pengfei, Liu, Chuntai, Sun, Shuhui, Chou, Shu‐Lei, Shen, Changyu · 2021 · Angewandte Chemie International Edition

Abstract

High initial coulombic efficiency is highly desired because it implies effective interface construction and few electrolyte consumption, indicating enhanced batteries’ life and power output. In this work, a high‐capacity sodium storage material with FeS 2 nanoclusters (≈1–2 nm) embedded in N, S‐doped carbon matrix (FeS 2/N,S‐C) was synthesized, the surface of which displays defects‐repaired characteristic and detectable dot‐matrix distributed Fe‐N‐C/Fe‐S‐C bonds. After the initial discharging process, the uniform ultra‐thin NaF‐rich (≈6.0 nm) solid electrolyte interphase was obtained, thereby achieving verifiable ultra‐high initial coulombic efficiency (≈92 %). The defects‐repaired surface provides perfect platform, and the catalysis of dot‐matrix distributed Fe‐N‐C/Fe‐S‐C bonds to the rapid decomposing of NaSO 3 CF 3 and diethylene glycol dimethyl ether successfully accelerate the building of two‐dimensional ultra‐thin solid electrolyte interphase. DFT calculations further confirmed the catalysis mechanism. As a result, the constructed FeS 2/N,S‐C provides high reversible capacity (749.6 mAh g−1 at 0.1 A g−1) and outstanding cycle stability (92.7 %, 10 000 cycles, 10.0 A g−1). Especially, at −15 °C, it also obtains a reversible capacity of 211.7 mAh g−1 at 10.0 A g−1. Assembled pouch‐type cell performs potential application. The insight in this work provides a bright way to interface design for performance improvement in batteries.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/anie.202102368

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 216

Metadata

Authors
Wan, Y., Song, K., Chen, W., Qin, C., Zhang, X., Zhang, J., Dai, H., Hu, Z., Yan, P., Liu, C., Sun, S., Chou, S., & Shen, C.
Venue
Angewandte Chemie International Edition
Publisher
Wiley
Published
2021-04-06
Volume
60
Issue
20
Pages
11481-11486
ISSN
  • 1433-7851 (ISSN-L)
  • 1521-3773
OpenAlex
W3133965473
Cited by
216
References
3
FWCI
11.88
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Ultra‐High Initial Coulombic Efficiency Induced by Interface Engineering Enables Rapid, Stable Sodium Storage. https://app.cochat.ai/papers/10.1002/anie.202102368
The paper
Wan, Y., Song, K., Chen, W., Qin, C., Zhang, X., Zhang, J., Dai, H., Hu, Z., Yan, P., Liu, C., Sun, S., Chou, S., & Shen, C. (2021). Ultra‐High Initial Coulombic Efficiency Induced by Interface Engineering Enables Rapid, Stable Sodium Storage. Angewandte Chemie International Edition. https://doi.org/10.1002/anie.202102368

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.