Atrioventricular node and input pathways: A correlated gross anatomical and histological study of the canine atrioventricular junctional region
The DOI matches its Crossref record.
Abstract
To determine the architecture of the atrioventricular (AV) junctional region, structures in atrial preparations were correlated to those in serial sections made either parallel or perpendicular to the long axis of the AV node (AVN)/AV bundle complex. The results demonstrated the following for the first time: (1) A right medial atrial wall (MAW) extends anteriorly from the interatrial septum, superior to the interventricular septum (IVS). (2) An atrial interventricular septum (A‐IVS) groove is located between the base of the MAW and the crest of the IVS. (3) Three atrionodal bundles converge to form a proximal AV bundle (PAVB), which in turn is contiguous with the AVN. The atrionodal bundles are associated with the MAW or the superomedial and inferolateral margins of the coronory sinus. Terminal portions of the atrionodal bundles and the PAVB reside within the A‐IVS groove. The AV bundle was termed distal (DAVB) to avoid confusion. (4) The location of the AVN/DAVB complex topographically is deep to the apex of the septal cusp of the tricuspid valve subjacent to the MAW. Intracardially, the AVN/DAVB complex is within the central fibrous body. Significantly, this study resulted in the first unequivocal demonstration of discrete bundles of myocardial fibers associated with the atrial end of the AV node. Moreover, it appears likely that the atrionodal AV bundles are continuous with the sinoatrial nodal extensions, thereby forming internodal tracts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
McGuire, M. A., Bourke, J. P., Robotin, M. C., Johnson, D. C., Meldrum-Hanna, W., Nunn, G. R., Uther, J. B., & Ross, D. L. (1993) · Circulation · doi:10.1161/01.cir.88.5.2315 · Cited by 167
Atrial Flutter Mapping and Ablation I: Studying Atrial Flutter Mechanisms by Mapping and Entrainment
COSIO, F. G., ARRIBAS, F., LÓPEZ‐GIL, M., & PALACIOS, J. (1996) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1996.tb03368.x · Cited by 111
Inappropriate Sinus Tachycardia After Radiofrequency Ablation of Para‐Hisian Accessory Pathways
PAPPONE, C., STABILE, G., ORETO, G., DE SIMONE, A., RILLO, M., MAZZONE, P., CAPPATO, R., & CHIERCHIA, S. (1997) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1997.tb01032.x · Cited by 42
Radiofrequency Ablation of Atrial Flutter: A Randomized Controlled Trial of Two Anatomic Approaches
Passman, R. S., Kadish, A. H., Dibs, S. R., Engelstein, E. D., & Goldberger, J. J. (2004) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2004.00390.x · Cited by 24
Metadata
- Authors
- Racker, D. K.
- Venue
- The Anatomical Record
- Publisher
- Wiley
- Published
- 1989-07
- Volume
- 224
- Issue
- 3
- Pages
- 336-354
- ISSN
- 0003-276X (ISSN-L)
- 1097-0185
- OpenAlex
- W2026761798
- Cited by
- 90
- References
- 0
- FWCI
- 1.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.