CoChat

Adaptation of cancellous bone to overloading in the adult rat: A single photon absorptiometry and histomorphometry study

Jee, Webster S. S., Li, Xiao Jian · 1990 · The Anatomical Record
Cited by 125

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Nine‐month‐old female rats were subjected to right hindlimb immobilization or served as controls for 0, 2, 10, 18, and 26 weeks and were double‐labeled with bone markers. The right limb was immobilized against the abdomen and considered unloaded, while the left limb was overloaded during ambulation. Single‐photon absorptiometry was performed on intact femur; static and dynamic histomorphometry were performed on 20 μm thick undecalcified frontal sections of the proximal tibial metaphysis. Changes in the continuously overloaded limb was compared to that in both limbs of age‐matched control animals. Single‐photon absorptiometry detected increases of bone mineral density of +6%, +6%, and +5% in the proximal and +9%, +7%, and +10% in the distal femoral metaphyses after 10, 18, and 26 weeks of continuous overloading. Morphometrically, significant changes occurred in proximal tibial metaphyses compared to age‐matched controls; trabecular area increased +41% and +45%, trabecular number increased +31% and +32%, and trabecular separation decreased −30% and −31% after 18 and 26 weeks of overloading. A significant increase in mineral apposition rate (+38%) was found only at 26 weeks of overloading. Insignificant decreases in both eroded and labeled bone surfaces occurred at all time periods. The histomorphometric changes indicated that increased cancellous bone mass was caused by an increase in bone formation activity (i.e., increases in mineral apposition and bone formation rates) and a decrease in remodeling space (i.e., decrease in bone eroded surface). These findings indicate that the adult skeleton can quickly adapt to the increased biomechanical needs by increasing its cancellous bone mass with an adequate structural pattern. It further support Frost's postulate that increasing skeletal mechanical usage stimulates bone modeling and depresses bone remodeling to increase and maintain bone mass.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/ar.1092270405

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Jee, W. S. S., & Li, X. J.
Venue
The Anatomical Record
Publisher
Wiley
Published
1990-08
Volume
227
Issue
4
Pages
418-426
ISSN
  • 0003-276X (ISSN-L)
  • 1097-0185
OpenAlex
W2014956805
Cited by
125
References
2
FWCI
11.86
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.