The DOI matches its Crossref record; the references it cites are not checked yet.
Square wave voltammetric detection of cholesterol with biosensor based on poly(styrene‐‐ε‐caprolactone)/MWCNTs composite
Abstract
A novel poly(styrene‐‐ε‐caprolactone)/multiwalled carbon nanotubes/cholesterol oxidase film‐coated glassy carbon electrode was designed for cholesterol detection by square wave voltammetry (SWV). The biosensor responded to cholesterol with a measurement concentration range between 1 and 130 μM, a relative standard deviation of only 0.095% and accuracy of 100.42% ±2.85 with the SWV technique in the potential range from −0.6 to +0.6 V. The limit of detection was calculated to be 0.63 μM. The biosensor was preserved 91 and 84% of its initial response at the end of the 9st and 25st days, respectively. Human serum from human male AB plasma was analyzed without pretreatment except for dilution to investigate the performance of the biosensor in a complex medium.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
The citation lists haven’t been fetched yet
Cited by 3
Research works printed but not linked: 66
- 10.1016/j.jsamd.2020.06.001 · doi:10.1016/j.jsamd.2020.06.001
- 10.1016/j.steroids.2018.12.003 · DOI · Paper page
- 10.1016/j.ijbiomac.2018.08.163 · doi:10.1016/j.ijbiomac.2018.08.163
- 10.1002/slct.201803871 · DOI · Paper page
- 10.1016/j.bios.2015.08.042 · DOI
- 10.1016/S0009-8981(99)00174-6 · doi:10.1016/s0009-8981(99)00174-6
- Allain C, FuPC 1974. Enzymatic determination of total serum cholesterol, Clin Chem., 470
- 10.1016/S0165-022X(98)00036-0 · DOI · Paper page
- 10.1021/ac60204a066 · doi:10.1021/ac60204a066
- 10.1093/clinchem/45.12.2158 · doi:10.1093/clinchem/45.12.2158
- Kroger S, 1997, Chapter 13: Calorimetric Biosensors. Handbook of Biosensors and Electronic Noses—Medicine, Food, and the Environment, 279
- 10.1016/j.snb.2014.05.114 · DOI
- 10.3390/s18103368 · DOI · Paper page
- Wang X, 2013, Polymers for biosensors construction, State of the Art in Biosensors—General Aspects, 3, 67
- Pal PS, 2002, Polymers in biosensors: a review, J Indian Chem Soc., 79, 211
- 10.1002/apj.2374 · doi:10.1002/apj.2374
- 10.1016/j.foodchem.2015.02.104 · DOI
- 10.1016/j.ijbiomac.2019.01.001 · DOI
- 10.1021/nl901852h · doi:10.1021/nl901852h
- 10.1021/jp801938w · DOI
- 10.1007/s00604-019-3883-x · doi:10.1007/s00604-019-3883-x
- 10.1016/j.foodchem.2021.129578 · doi:10.1016/j.foodchem.2021.129578
- 10.1007/s12161-020-01820-5 · doi:10.1007/s12161-020-01820-5
- 10.3389/fchem.2019.00888 · doi:10.3389/fchem.2019.00888
- 10.1007/s13233-014-2078-x · DOI
- 10.3390/polym8010020 · DOI · Paper page
- 10.3390/polym10121387 · DOI
- Kumar S, Amine‐functionalized multiwall carbon nanotubes impart osteoinductive and bactericidal properties in poly (3‐caprolactone) composites, RSC Adv., 4
- 10.1002/elan.200403117 · DOI
- 10.1016/j.bios.2015.06.016 · doi:10.1016/j.bios.2015.06.016
- 10.1016/S0009-2614(03)00187-8 · DOI
- 10.1021/la049344j · doi:10.1021/la049344j
- 10.1016/j.cis.2006.11.007 · DOI · Paper page
- 10.1016/j.bios.2007.10.018 · DOI · Paper page
- 10.1149/2.0252003JES · DOI · Paper page
- 10.1016/j.proche.2014.10.087 · doi:10.1016/j.proche.2014.10.087
- 10.1016/j.snb.2007.07.008 · doi:10.1016/j.snb.2007.07.008
- 10.1016/j.electacta.2013.03.118 · doi:10.1016/j.electacta.2013.03.118
- 10.4236/aim.2012.22007 · doi:10.4236/aim.2012.22007
- 10.1111/j.1742-4658.2009.07377.x · doi:10.1111/j.1742-4658.2009.07377.x
- 10.1080/21691401.2016.1178133 · doi:10.1080/21691401.2016.1178133
- 10.1016/j.jcat.2021.04.018 · DOI
- 10.1016/j.bios.2017.11.037 · DOI
- 10.1016/j.snb.2015.06.054 · DOI
- 10.1016/j.jelechem.2016.06.033 · DOI
- 10.1016/j.msec.2017.03.253 · doi:10.1016/j.msec.2017.03.253
- 10.1166/sl.2014.3338 · doi:10.1166/sl.2014.3338
- 10.1016/j.jallcom.2016.05.063 · doi:10.1016/j.jallcom.2016.05.063
- 10.1016/j.talanta.2005.08.036 · doi:10.1016/j.talanta.2005.08.036
- 10.1016/j.msec.2014.10.077 · doi:10.1016/j.msec.2014.10.077
- 10.2144/btn-2019-0126 · DOI
- 10.1016/j.bios.2013.08.018 · DOI · Paper page
- Jeng‐You Yang YL, 2011, Fabrication of a Cholesterol Biosensor Based on Cholesterol Oxidase and Multiwall Carbon Nanotube Hybrid Composites, Int J Electrochem Sci., 6, 2223, 10.1016/S1452-3981(23)18179-X · DOI
- 10.1016/j.snb.2006.11.051 · doi:10.1016/j.snb.2006.11.051
- 10.1016/j.jelechem.2011.07.040 · doi:10.1016/j.jelechem.2011.07.040
- 10.1016/j.snb.2015.02.045 · doi:10.1016/j.snb.2015.02.045
- 10.1016/j.bios.2010.12.009 · doi:10.1016/j.bios.2010.12.009
- 10.31788/RJC.2021.1436251 · doi:10.31788/rjc.2021.1436251
- 10.1016/j.bioelechem.2019.01.008 · doi:10.1016/j.bioelechem.2019.01.008
- 10.1016/j.aca.2008.04.010 · DOI · Paper page
- 10.2116/analsci.18.537 · doi:10.2116/analsci.18.537
- 10.1080/17458080.2010.487230 · doi:10.1080/17458080.2010.487230
- 10.1016/j.ab.2004.10.040 · doi:10.1016/j.ab.2004.10.040
- 10.1002/elan.201800248 · doi:10.1002/elan.201800248
- 10.1016/j.jpba.2018.07.005 · doi:10.1016/j.jpba.2018.07.005
- 10.1039/C5AN01843A · doi:10.1039/c5an01843a
Metadata
- Authors
- Kavacık, M., & Kilic, M. S.
- Venue
- Biotechnology and Applied Biochemistry
- Publisher
- Wiley
- Published
- 2023-01-16
- Volume
- 70
- Issue
- 3
- Pages
- 1137-1148
- ISSN
- 0885-4513
- 1470-8744
- Cited by
- 3
- Language
- en
- Licence
- onlinelibrary.wiley.com/termsAndConditions#vor (vor)
- doi.wiley.com/10.1002/tdm_license_1.1 (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Square wave voltammetric detection of cholesterol with biosensor based on poly(styrene‐‐ε‐caprolactone)/MWCNTs composite. https://app.cochat.ai/papers/10.1002/bab.2427
- The paper
- Kavacık, M., & Kilic, M. S. (2023). Square wave voltammetric detection of cholesterol with biosensor based on poly(styrene‐‐ε‐caprolactone)/MWCNTs composite. Biotechnology and Applied Biochemistry. https://doi.org/10.1002/bab.2427
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.