The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Tendon‐to‐bone attachment: From development to maturity
Open accessAbstract
The attachment between tendon and bone occurs across a complex transitional tissue that minimizes stress concentrations and allows for load transfer between muscles and skeleton. This unique tissue cannot be reconstructed following injury, leading to high incidence of recurrent failure and stressing the need for new clinical approaches. This review describes the current understanding of the development and function of the attachment site between tendon and bone. The embryonic attachment unit, namely, the tip of the tendon and the bone eminence into which it is inserted, was recently shown to develop modularly from a unique population of Sox9‐ and Scx‐positive cells, which are distinct from tendon fibroblasts and chondrocytes. The fate and differentiation of these cells is regulated by transforming growth factor beta and bone morphogenetic protein signaling, respectively. Muscle loads are then necessary for the tissue to mature and mineralize. Mineralization of the attachment unit, which occurs postnatally at most sites, is largely controlled by an Indian hedgehog/parathyroid hormone‐related protein feedback loop. A number of fundamental questions regarding the development of this remarkable attachment system require further study. These relate to the signaling mechanism that facilitates the formation of an interface with a gradient of cellular and extracellular phenotypes, as well as to the interactions between tendon and bone at the point of attachment. Birth Defects Research (Part C) 102:101–112, 2014. © 2014 Wiley Periodicals, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Akiyama, H., Chaboissier, M.-C., Martin, J. F., Schedl, A., & de Crombrugghe, B. (2002) · Genes & Development · doi:10.1101/gad.1017802 · Cited by 1,721
Cited by
Berendsen, A. D., & Olsen, B. R. (2015) · Bone · doi:10.1016/j.bone.2015.04.035 · Cited by 559
Tendon injury: from biology to tendon repair
Nourissat, G., Berenbaum, F., & Duprez, D. (2015) · Nature Reviews Rheumatology · doi:10.1038/nrrheum.2015.26 · Cited by 509
Strategies to engineer tendon/ligament-to-bone interface: Biomaterials, cells and growth factors
Font Tellado, S., Balmayor, E. R., & Van Griensven, M. (2015) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.03.004 · Cited by 286
Su, M., Zhang, Q., Zhu, Y., Wang, S., Lv, J., Sun, J., Qiu, P., Fan, S., Jin, K., Chen, L., et al. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201900831 · Cited by 50
Shi, Q., Chen, Y., Li, M., Zhang, T., Ding, S., Xu, Y., Hu, J., Chen, C., & Lu, H. (2020) · Annals of Translational Medicine · doi:10.21037/atm-20-3661 · Cited by 16
Metadata
- Authors
- Zelzer, E., Blitz, E., Killian, M. L., & Thomopoulos, S.
- Venue
- Birth Defects Research Part C: Embryo Today: Reviews
- Publisher
- Wiley
- Published
- 2014-03
- Volume
- 102
- Issue
- 1
- Pages
- 101-112
- ISSN
- 1542-975X (ISSN-L)
- 1542-9768
- OpenAlex
- W1949873766
- Cited by
- 177
- References
- 1
- FWCI
- 12.22
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tendon‐to‐bone attachment: From development to maturity. https://app.cochat.ai/papers/10.1002/bdrc.21056
- The paper
- Zelzer, E., Blitz, E., Killian, M. L., & Thomopoulos, S. (2014). Tendon‐to‐bone attachment: From development to maturity. Birth Defects Research Part C: Embryo Today: Reviews. https://doi.org/10.1002/bdrc.21056
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.