Permeability changes induced by 130 GHz pulsed radiation on cationic liposomes loaded with carbonic anhydrase
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The effects of pulsed 130 GHz radiations on lipid membrane permeability were investigated by using cationic liposomes containing dipalmitoyl phosphatidylcholine (DPPC), cholesterol, and stearylamine. Carbonic anhydrase (CA) was loaded inside the liposomes and the substrate p‐nitrophenyl acetate (p‐NPA) added in the bulk aqueous phase. Upon permeation across the lipid bilayer, the trapped CA catalyzes the conversion of the p‐NPA molecules into products. Because the self‐diffusion rate of p‐NPA across intact liposomes is very low the CA reaction rate, expressed as Δ A/min, is used to track membrane permeability changes. The effect of 130 GHz radiation pulse‐modulated at low frequencies of 5, 7, or 10 Hz, and at time‐averaged incident intensity (IAV) up to 17 mW/cm 2 was studied at room temperature (22 °C), below the phase transition temperature of DPPC liposomes. At all the tested values of IAV a significant enhancement of the enzyme reaction rate in CA‐loaded liposomes occurred when the pulse repetition rate was 7 Hz. Typically, an increase from Δ A/min = 0.0026 ± 0.0010 (n = 11) to Δ A/min = 0.0045 ± 0.0013 (n = 12) (P < 0.0005) resulted at IAV = 7.7 mW/cm 2. The effect of 130 GHz pulse‐modulated at 7 Hz was also observed on cationic liposomes formed with palmitoyloleoyl phosphatidylcholine (POPC), at room temperature (22 °C), above the phase transition temperature of POPC liposomes. Bioelectromagnetics 28:587–598, 2007. © 2007 Wiley‐Liss, Inc.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175 · cited 1×
“9were derived from the data of Gabriel et al., 1996.”
Cited by
Invited Review Article: Current State of Research on Biological Effects of Terahertz Radiation
Wilmink, G. J., & Grundt, J. E. (2011) · Journal of Infrared, Millimeter, and Terahertz Waves · doi:10.1007/s10762-011-9794-5 · Cited by 314
Wu, T., Rappaport, T. S., & Collins, C. M. (2015) · IEEE Microwave Magazine · doi:10.1109/mmm.2014.2377587 · Cited by 243
“3 mW/cm2) modified the shape and enhanced the permeability of liposomal vesicles, which implies that membranes are affected by mmWave radiation [101], [102].”
Perspective on Terahertz Applications in Bioscience and Biotechnology
Markelz, A. G., & Mittleman, D. M. (2022) · ACS Photonics · doi:10.1021/acsphotonics.2c00228 · Cited by 178
Terahertz Electromagnetic Fields (0.106 THz) Do Not Induce Manifest Genomic Damage In Vitro
Hintzsche, H., Jastrow, C., Kleine-Ostmann, T., Kärst, U., Schrader, T., & Stopper, H. (2012) · PLoS ONE · doi:10.1371/journal.pone.0046397 · Cited by 57
“1 THz [16,17,18].”
Metadata
- Authors
- Ramundo‐Orlando, A., Gallerano, G. P., Stano, P., Doria, A., Giovenale, E., Messina, G., Cappelli, M., D'Arienzo, M., & Spassovsky, I.
- Venue
- Bioelectromagnetics
- Publisher
- Wiley
- Published
- 2007-07-09
- Volume
- 28
- Issue
- 8
- Pages
- 587-598
- ISSN
- 0197-8462 (ISSN-L)
- 1521-186X
- OpenAlex
- W2099185645
- Cited by
- 58
- References
- 1
- FWCI
- 1.42
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Permeability changes induced by 130 GHz pulsed radiation on cationic liposomes loaded with carbonic anhydrase. https://app.cochat.ai/papers/10.1002/bem.20343
- The paper
- Ramundo‐Orlando, A., Gallerano, G. P., Stano, P., Doria, A., Giovenale, E., Messina, G., Cappelli, M., D'Arienzo, M., & Spassovsky, I. (2007). Permeability changes induced by 130 GHz pulsed radiation on cationic liposomes loaded with carbonic anhydrase. Bioelectromagnetics. https://doi.org/10.1002/bem.20343
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.