Simulated biological materials for electromagnetic radiation absorption studies
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
For the study of electromagnetic dosimetry and hyperthermia, it is necessary to simulate human biological materials. This can be done by chemical mixtures that are described in this paper. Formulas are presented for simulating bone, lung, brain, and muscle tissue in the frequency range of 100 MHz to 1 GHz. By using these preparations a realistic equivalent to the human body can be constructed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Guy, A. W. (1971) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.1968.1127484 · Cited by 454
Dielectric Properties of Biological Materials: Biophysical and Medical Applications
Pethig, R. (1984) · IEEE Transactions on Electrical Insulation · doi:10.1109/tei.1984.298769 · Cited by 363
Formulas for preparing phantom muscle tissue at various radiofrequencies
Chou, C., Chen, G., Guy, A. W., & Luk, K. H. (1984) · Bioelectromagnetics · doi:10.1002/bem.2250050408 · Cited by 253
Dielectric properties of brain tissue between 0.01 and 10 GHz
Foster, K. R., Schepps, J. L., Stoy, R. D., & Schwan, H. P. (1979) · Physics in Medicine & Biology · doi:10.1088/0031-9155/24/6/008 · Cited by 162
Multiterm Debye Dispersion Relations for Permittivity of Muscle
Hurt, W. D. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325629 · Cited by 117
Cited by
Electrical Properties of Tissue
Duck, F. A. (1990) · Physical Properties of Tissues · doi:10.1016/b978-0-12-222800-1.50010-3 · Cited by 242
Development and characteristics of a biological tissue-equivalent phantom for microwaves
Ito, K., Furuya, K., Okano, Y., & Hamada, L. (2001) · Electronics and Communications in Japan (Part I: Communications) · doi:10.1002/1520-6424(200104)84:4<67::aid-ecja8>3.0.co;2-d · Cited by 187
Recent Advances in Fabrication Methods for Flexible Antennas in Wearable Devices: State of the Art
Mohamadzade, B., Hashmi, R. M., Simorangkir, R. B. V. B., Gharaei, R., Ur Rehman, S., & Abbasi, Q. H. (2019) · Sensors · doi:10.3390/s19102312 · Cited by 160
“The preparation of liquid phantoms is relatively the easiest as it involves only the mixing of composing materials following an appropriate recipe (see [109]).”
BackgroundChow, E., Morris, M., & Irazoqui, P. (2013) · IEEE Microwave Magazine · doi:10.1109/mmm.2013.2248586 · Cited by 111
Metadata
- Authors
- Hartsgrove, G., Kraszewski, A., & Surowiec, A.
- Venue
- Bioelectromagnetics
- Publisher
- Wiley
- Published
- 1987-01
- Volume
- 8
- Issue
- 1
- Pages
- 29-36
- ISSN
- 0197-8462 (ISSN-L)
- 1521-186X
- OpenAlex
- W2109092819
- Cited by
- 203
- References
- 5
- FWCI
- 3.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.