Cited by 111Wireless Body Area NetworksWireless Power Transfer SystemsRFID technology advancements

Implantable RF medical devices: the benefits of high-speed communication and much greater communication distances in biomedical applications

Chow, Eric, Morris, Milton, Irazoqui, Pedro·2013·IEEE Microwave Magazine

Abstract

In the early ages of implantable devices, radio frequency (RF) technologies were not commonplace due to the challenges stemming from the inherent nature of biological tissue boundaries. As technology improved and our understanding matured, the benefit of RF in biomedical applications surpassed the implementation challenges and is thus becoming more widespread. The fundamental challenge is due to the significant electromagnetic (EM) effects of the body at high frequencies. The EM absorption and impedance boundaries of biological tissue result in significant reduction of power and signal integrity for transcutaneous propagation of RF fields. Furthermore, the dielectric properties of the body tissue surrounding the implant must be accounted for in the design of its RF components, such as antennas and inductors, and the tissue is often heterogeneous and the properties are highly variable. Additional challenges for implantable applications include the need for miniaturization, power minimization, and often accounting for a conductive casing due to biocompatibility and hermeticity requirements [1]?[3]. Today, wireless technologies are essentially a must have in most electrical implants due to the need to communicate with the device and even transfer usable energy to the implant [4], [5]. Low-frequency wireless technologies face fewer challenges in this implantable setting than its higher frequency, or RF, counterpart, but are limited to much lower communication speeds and typically have a very limited operating distance. The benefits of high-speed communication and much greater communication distances in biomedical applications have spawned numerous wireless standards committees, and the U.S. Federal Communications Commission (FCC) has allocated numerous frequency bands for medical telemetry as well as those to specifically target implantable applications. The development of analytical models, advanced EM simulation software, and representative RF human phantom recipes has significantly facilitated design and optimization of RF components for implantable applications.

Integrity signals

Registry

Crossref · 10.1109/mmm.2013.2248586

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Radio Frequency (RF) technology employs far-field electromagnetic waves in the MHz and GHz range to wirelessly transmit energy and data over greater distances to brain implants.

    “Radio Frequency (RF) technology employs far-field electromagnetic waves in the MHz and GHz range to wirelessly transmit energy and data over greater distances to brain implants differentiating it from the near-field magnetic fields utilized in inductive coupling and the intermediate-range operations of Midfield Transfer (MDF).”

    From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Chow et al., 2013

  • An external transmitter generates RF waves, captured by an antenna connected to an internal receiver in the implant, where it is converted to electrical power.

    “An external transmitter generates these waves, captured by an antenna connected to an internal receiver in the implant, where it is converted to electrical power (Chow et al., 2013; Singer and Robinson, 2021).”

    From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Chow et al., 2013

Cites

Flagged first, then by citations

3 of the 36 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Chow, E., Morris, M., & Irazoqui, P.
Affiliations
Purdue University West Lafayette (US)
Venue
IEEE Microwave Magazine
Published
2013-06
Volume
14
Issue
4
Pages
64-73
ISSN
1527-3342 (ISSN-L)
OpenAlex
W1970635841
Cited by
111
References
36
Citations by year
2026: 4 · 2025: 6 · 2024: 14 · 2023: 5 · 2022: 4 · 2021: 4 · 2020: 7 · 2019: 9 · 2018: 13 · 2017: 12 · 2016: 7 · 2015: 12 · 2014: 9 · 2013: 5
FWCI
6.07
Type
journal article
Language
en
Open access
closed
Locations
IEEE Microwave Magazine (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
  • Physical Sciences › Engineering › Media Technology › RFID technology advancements
Keywords
high-speed wireless communication, biotelemetry, tissue dielectric properties, electromagnetic wave absorption, impedance matching, RF power transmission

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review