The DOI matches its Crossref record.
Medical applications of Raman spectroscopy: From proof of principle to clinical implementation
Open accessAbstract
Raman spectroscopy has recently been applied ex vivo and in vivo to address various biomedical issues such as the early detection of cancers, monitoring of the effect of various agents on the skin, determination of atherosclerotic plaque composition, and rapid identification of pathogenic microorganisms. This leap in the number of applications and the number of groups active in this field has been facilitated by several technological advancements in lasers, CCD detectors, and fiber‐optic probes. However, most of the studies are still at the proof of concept stage. We present a discussion on the status of the field today, as well as the problems and issues that still need to be resolved to bring this technology to hospital settings (i.e., the medical laboratory, surgical suites, or clinics). Taken from the viewpoint of clinicians and medical analysts, the potential of Raman spectroscopic techniques as new tools for biomedical applications is discussed and a path is proposed for the clinical implementation of these techniques. © 2002 John Wiley & Sons, Inc. Biopolymers (Biospectroscopy) 67: 1–9, 2002; DOI 10.1002/bip.10064
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Raman Spectroscopy of Biological Tissues
Movasaghi, Z., Rehman, S., & Rehman, I. U. (2007) · Applied Spectroscopy Reviews · doi:10.1080/05704920701551530 · Cited by 2,518
Chemical imaging of tissue in vivo with video-rate coherent anti-Stokes Raman scattering microscopy
Evans, C. L., Potma, E. O., Puoris'haag, M., Côté, D., Lin, C. P., & Xie, X. S. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0508282102 · Cited by 957
Advances in Fourier transform infrared (FTIR) spectroscopy of biological tissues
Talari, A. C. S., Martinez, M. A. G., Movasaghi, Z., Rehman, S., & Rehman, I. U. (2017) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2016.1230863 · Cited by 533
Raman Spectroscopy Detects Biochemical Changes Due to Proliferation in Mammalian Cell Cultures
Short, K. W., Carpenter, S., Freyer, J. P., & Mourant, J. R. (2005) · Biophysical Journal · doi:10.1529/biophysj.103.038604 · Cited by 286
Raman imaging at biological interfaces: applications in breast cancer diagnosis
Surmacki, J., Musial, J., Kordek, R., & Abramczyk, H. (2013) · Molecular Cancer · doi:10.1186/1476-4598-12-48 · Cited by 143
Metadata
- Authors
- Choo‐Smith, L. ‐., Edwards, H. G. M., Endtz, H. P., Kros, J. M., Heule, F., Barr, H., Robinson, J. S., Bruining, H. A., & Puppels, G. J.
- Venue
- Biopolymers
- Publisher
- Wiley
- Published
- 2002-01
- Volume
- 67
- Issue
- 1
- Pages
- 1-9
- ISSN
- 0006-3525 (ISSN-L)
- 1097-0282
- OpenAlex
- W2087900161
- Cited by
- 280
- References
- 0
- FWCI
- 4.68
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Medical applications of Raman spectroscopy: From proof of principle to clinical implementation. https://app.cochat.ai/papers/10.1002/bip.10064
- The paper
- Choo‐Smith, L. ‐., Edwards, H. G. M., Endtz, H. P., Kros, J. M., Heule, F., Barr, H., Robinson, J. S., Bruining, H. A., & Puppels, G. J. (2002). Medical applications of Raman spectroscopy: From proof of principle to clinical implementation. Biopolymers. https://doi.org/10.1002/bip.10064
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.