The DOI matches its Crossref record.
Fluorescence correlation spectroscopy. III. Uniform translation and laminar flow
Abstract
We extend fluorescence correlation spectroscopy to systems that undergo translation or laminar flow in a sample cell. We include theoretical and experimental results; we consider uniform and nonuniform velocity profiles. Concentration correlation analysis extracts microscopic rate parameters from measurements of the spontaneous concentration fluctutations, which occur even at equilibrium. Fluorescence is one of the most sensitive means of monitoring these fluctuations. Analysis of flowing or translating systems (1) offers a method of measuring number concentrations of selected species, for example, of aggregates or polymers, (2) provides a nonperturbing velocity probe, (3) sometimes allows one to circumvent photolytic degradation, (4) has proved extremely helpful in testing and aliging apparatus for fluorescence correaltion measurement and in verifying theoretical analyses, and (5) may be required for interpretation of results obtained on systems in motion, even though that motion is undesired or initially unsuspected. We include both theoretical and experimental results for combined Poiseuille flow and diffusion in the geometry which is of most practical interest. Theoretical expressions for the much simpler cases of nondiffusive Poiseuille flow as well as uniform flow or translation with or without diffusion constitute limiting cases which are displayed explicitly.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Measuring Fast Dynamics in Solutions and Cells with a Laser Scanning Microscope
Digman, M. A., Brown, C. M., Sengupta, P., Wiseman, P. W., Horwitz, A. R., & Gratton, E. (2005) · Biophysical Journal · doi:10.1529/biophysj.105.062836 · Cited by 462
Fluorescence correlation spectroscopy in living cells
Kim, S. A., Heinze, K. G., & Schwille, P. (2007) · Nature Methods · doi:10.1038/nmeth1104 · Cited by 444
Fluorescence Correlation Spectroscopy: Past, Present, Future
Elson, E. L. (2011) · Biophysical Journal · doi:10.1016/j.bpj.2011.11.012 · Cited by 438
Self-citationFluorescence correlation spectroscopy: Diagnostics for sparse molecules
Maiti, S., Haupts, U., & Webb, W. W. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.22.11753 · Cited by 317
Self-citationSingle-molecule spectroscopy and imaging over the decades
Moerner, W. E., Shechtman, Y., & Wang, Q. (2015) · Faraday Discussions · doi:10.1039/c5fd00149h · Cited by 103
Metadata
- Authors
- Magde, D., Webb, W. W., & Elson, E. L.
- Venue
- Biopolymers
- Publisher
- Wiley
- Published
- 1978-02
- Volume
- 17
- Issue
- 2
- Pages
- 361-376
- ISSN
- 0006-3525 (ISSN-L)
- 1097-0282
- OpenAlex
- W2078162698
- Cited by
- 298
- References
- 0
- FWCI
- 2.03
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluorescence correlation spectroscopy. III. Uniform translation and laminar flow. https://app.cochat.ai/papers/10.1002/bip.1978.360170208
- The paper
- Magde, D., Webb, W. W., & Elson, E. L. (1978). Fluorescence correlation spectroscopy. III. Uniform translation and laminar flow. Biopolymers. https://doi.org/10.1002/bip.1978.360170208
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.