Use of at‐line and in‐situ near‐infrared spectroscopy to monitor biomass in an industrial fed‐batch Escherichia coli process
The DOI matches its Crossref record.
Abstract
One of the key goals in bioprocess monitoring is to achieve real‐time knowledge of conditions within the bioreactor, i.e., in‐situ. Near‐infrared spectroscopy (NIRS), with its ability to carry out multi‐analyte quantification rapidly with little sample presentation, is potentially applicable in this role. In the present study, the application of NIRS to a complex, fed‐batch industrial E. coli (RV308/PHKY531) process was investigated. This process undergoes a series of temperature changes and is vigorously agitated and aerated. These conditions can pose added challenges to in‐situ NIRS. Using the measurement of a key analyte (biomass) as an illustration, the details of the relationship between the at‐line and in‐situ use of NIRS are considered from the viewpoint of both theory and practical application. This study shows that NIRS can be used both at‐line and in‐situ in order to achieve good predictive models for biomass. There are particular challenges imposed by in‐situ operation (loss of wavelength regions and noise) which meant the need for signal optimisation studies. This showed that whilst the at‐line modelling process may provide some useful information for the in‐situ process, there were distinct differences. This study shows that the in‐situ use of NIRS in a highly challenging matrix (similar to those encountered in current industrial practice) is possible, and thus extends previous works in the area. © 2002 Wiley Periodicals, Inc. Biotechnol Bioeng 80: 405–413, 2002.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Application of flow cytometry to industrial microbial bioprocesses
Díaz, M., Herrero, M., García, L. A., & Quirós, C. (2010) · Biochemical Engineering Journal · doi:10.1016/j.bej.2009.07.013 · Cited by 292
Bioreactor monitoring with spectroscopy and chemometrics: a review
Lourenço, N. D., Lopes, J. A., Almeida, C. F., Sarraguça, M. C., & Pinheiro, H. M. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6073-9 · Cited by 275
“However, ideal bioprocess monitoring is considered to be that which uses a probe located inside the bioreactor fluid, and is, therefore, capable of coping with the high agitation/aeration rates while generating real-time data, and having the ability to multiplex [66].”
BackgroundBroadband near-infrared phosphor BaMgAl10O17:Cr3+ realized by crystallographic site engineering
You, L., Tian, R., Zhou, T., & Xie, R.-J. (2021) · Chemical Engineering Journal · doi:10.1016/j.cej.2021.129224 · Cited by 254
Fisher, A. C., Kamga, M.-H., Agarabi, C., Brorson, K., Lee, S. L., & Yoon, S. (2019) · Trends in Biotechnology · doi:10.1016/j.tibtech.2018.08.008 · Cited by 180
Optical sensor systems for bioprocess monitoring
Ulber, R., Frerichs, J.-G., & Beutel, S. (2003) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-1930-1 · Cited by 151
Metadata
- Authors
- Arnold, S. A., Gaensakoo, R., Harvey, L. M., & McNeil, B.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2002-09-23
- Volume
- 80
- Issue
- 4
- Pages
- 405-413
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W1975834796
- Cited by
- 126
- References
- 0
- FWCI
- 4.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Use of at‐line and in‐situ near‐infrared spectroscopy to monitor biomass in an industrial fed‐batch Escherichia coli process. https://app.cochat.ai/papers/10.1002/bit.10383
- The paper
- Arnold, S. A., Gaensakoo, R., Harvey, L. M., & McNeil, B. (2002). Use of at‐line and in‐situ near‐infrared spectroscopy to monitor biomass in an industrial fed‐batch Escherichia coli process. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.10383
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.