CoChat

Scale‐up and optimization of an acoustic filter for 200 L/day perfusion of a CHO cell culture

Gorenflo, Volker M., Smith, Laura, Dedinsky, Bob, Persson, Bo, Piret, James M. · 2002 · Biotechnology and Bioengineering
Cited by 71

The DOI matches its Crossref record.

Abstract

Acoustic cell retention devices have provided a practical alternative for up to 50 L/day perfusion cultures but further scale‐up has been limited. A novel temperature‐controlled and larger‐scale acoustic separator was evaluated at up to 400 L/day for a 10 7 CHO cell/mL perfusion culture using a 100‐L bioreactor that produced up to 34 g/day recombinant protein. The increased active volume of this scaled‐up separator was divided into four parallel compartments for improved fluid dynamics. Operational settings of the acoustic separator were optimized and the limits of robust operations explored. The performance was not influenced over wide ranges of duty cycle stop and run times. The maximum performance of 96% separation efficiency at 200 L/day was obtained by setting the separator temperature to 35.1°C, the recirculation rate to three times the harvest rate, and the power to 90 W. While there was no detectable effect on culture viability, viable cells were selectively retained, especially at 50 L/day, where there was a 5‐fold higher nonviable washout efficiency. Overall, the new temperature‐controlled and scaled‐up separator design performed reliably in a way similar to smaller‐scale acoustic separators. These results provide strong support for the feasibility of much greater scale‐up of acoustic separations. © 2002 Wiley Periodicals, Inc. Biotechnol Bioeng 80: 438–444, 2002.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/bit.10386

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 71

Metadata

Authors
Gorenflo, V. M., Smith, L., Dedinsky, B., Persson, B., & Piret, J. M.
Venue
Biotechnology and Bioengineering
Publisher
Wiley
Published
2002-09-24
Volume
80
Issue
4
Pages
438-444
ISSN
  • 0006-3592 (ISSN-L)
  • 1097-0290
OpenAlex
W2169048007
Cited by
71
References
0
FWCI
1.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Scale‐up and optimization of an acoustic filter for 200 L/day perfusion of a CHO cell culture. https://app.cochat.ai/papers/10.1002/bit.10386
The paper
Gorenflo, V. M., Smith, L., Dedinsky, B., Persson, B., & Piret, J. M. (2002). Scale‐up and optimization of an acoustic filter for 200 L/day perfusion of a CHO cell culture. Biotechnology and Bioengineering. https://doi.org/10.1002/bit.10386

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.