Methodology for real‐time, multianalyte monitoring of fermentations using an in‐situ mid‐infrared sensor
Open accessThe DOI matches its Crossref record.
Abstract
An in‐situ, mid‐infrared sensor was used to monitor the major analyte concentrations involved in the cultivation of Gluconacetobacter xylinus and the production of gluconacetan, a food‐grade exopolysaccharide. To predict the analyte concentrations, three different sets of standard spectra were used to develop calibration models, applying partial least‐squares regression. It was possible to build a valid calibration model to predict the 700 spectra collected during the complete time course of the cultivation, using only 12 spectra collected every 10 h as standards. This model was used to reprocess the concentration profiles from 0 to 15 g/L of nine different analytes with a mean standard error of validation of 0.23 g/L. However, this calibration model was not suitable for real‐time monitoring as it was probably based on non‐specific spectral features, which were correlated only with the measured analyte concentrations. Valid calibration models capable of real‐time monitoring could be established by supplementing the set of 12 fermentation spectra with 42 standards of measured analytes. A pulse of 5 g/L ethanol showed the robustness of the model to sudden disturbances. The prediction of the models drifted, however, toward the end of the fermentation. The most robust calibration model was finally obtained by the addition of 34 standard spectra of non‐measured analytes. Although the spectra did not contain analyte‐specific information, it was believed that this addition would increase the variability space of the calibration model. Therefore, an expanded calibration model containing 88 spectra was used to monitor, in real time, the concentration profiles of fructose, acetic acid, ethanol and gluconacetan and allowed standard errors of prediction of 1.11, 0.37, 0.22, and 0.79 g/L, respectively. © 2003 Wiley Periodicals, Inc. Biotechnol Bioeng 82: 702–709, 2003.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sensor systems for bioprocess monitoring
Biechele, P., Busse, C., Solle, D., Scheper, T., & Reardon, K. (2015) · Engineering in Life Sciences · doi:10.1002/elsc.201500014 · Cited by 224
On-line infrared spectroscopy for bioprocess monitoring
Landgrebe, D., Haake, C., Höpfner, T., Beutel, S., Hitzmann, B., Scheper, T., Rhiel, M., & Reardon, K. F. (2010) · Applied Microbiology and Biotechnology · doi:10.1007/s00253-010-2743-8 · Cited by 134
“Kornmann et al. (2004) utilized attenuated total reflection-mid-infrared (ATR-MIR) for an on-line measurement of the substrate concentrations. This allowed the monitoring of the production and accumulation of the biomass by adding ethanol in a fed-batch process. The calibration was performed with synthetic solutions o…”
BackgroundMethodSelf-citationKoch, C., Brandstetter, M., Wechselberger, P., Lorantfy, B., Plata, M. R., Radel, S., Herwig, C., & Lendl, B. (2015) · Analytical Chemistry · doi:10.1021/ac504126v · Cited by 35
Metadata
- Authors
- Kornmann, H., Rhiel, M., Cannizzaro, C., Marison, I., & von Stockar, U.
- Venue
- Biotechnology and Bioengineering
- Publisher
- Wiley
- Published
- 2003-03-28
- Volume
- 82
- Issue
- 6
- Pages
- 702-709
- ISSN
- 0006-3592 (ISSN-L)
- 1097-0290
- OpenAlex
- W2027908641
- Cited by
- 56
- References
- 0
- FWCI
- 4.53
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.